Feasibility study of semi-automated measurements of finger joint space widths
The purpose of this study is to evaluate technical feasibility based on image capturing conditions (film-focus distance (FFD), film sensitivity, film brand, exposure level and tube voltage) that potentially alter radiographs and consequently may influence the semi-automated measurement of joint spac...
Saved in:
Published in: | Rheumatology international 2011-10, Vol.31 (10), p.1349-1354 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c436t-d5e3de0934b8f8c36b7b8a61b52f5f10697849023672439cdabc93f94a249e793 |
---|---|
cites | cdi_FETCH-LOGICAL-c436t-d5e3de0934b8f8c36b7b8a61b52f5f10697849023672439cdabc93f94a249e793 |
container_end_page | 1354 |
container_issue | 10 |
container_start_page | 1349 |
container_title | Rheumatology international |
container_volume | 31 |
creator | Pfeil, Alexander Sommerfeld, Julia Fröber, Rosemarie Lehmann, Gabriele Malich, Ansgar Hansch, Andreas Wolf, Gunter Böttcher, Joachim |
description | The purpose of this study is to evaluate technical feasibility based on image capturing conditions (film-focus distance (FFD), film sensitivity, film brand, exposure level and tube voltage) that potentially alter radiographs and consequently may influence the semi-automated measurement of joint space distance (JSD) by computer-aided joint space analysis (CAJSA) in rheumatoid arthritis and osteoarthritis. The radiographs of a left hand (deceased man) were acquired under systematically changing image capturing conditions (exposure level: 4–8 mAs; FFD: 90–130 cm; film sensitivity: 200/400 and tube voltage: 40–52 kV with different image modalities: conventional radiographs, original digital radiographs, digital print-outs). All JSD-measurements were performed with the CAJSA-technology (Radiogrammetry Kit, Version 1.3.6; Sectra; Sweden) at the metacarpal-phalangeal articulation. JSD-analysis was not influenced by changes of FFD, exposure level, film sensitivity or film brand. JSD showed significant variation caused by tube voltage (conventional: CV = 1.913% for Agfa and CV = 2.448% for Kodak; digital: CV = 0.741% for Philips print-outs and CV = 0.620% with original digital images versus CV = 2.185% for Siemens print-outs and 0.951% with original digital images). Computer-aided joint space analysis for JSD-measurements is unaffected by the following image capturing parameters: film-focus distance, film sensitivity, film brand and exposure level. An influence of tube voltage was detected in a lesser extent for original digital images compared to the printed digital as well as conventional versions. Consequently, a standardized tube voltage is essential for accurate reproductions of CAJSA-measurements in rheumatoid arthritis and osteoarthritis. |
doi_str_mv | 10.1007/s00296-010-1468-4 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_893981192</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2465072241</sourcerecordid><originalsourceid>FETCH-LOGICAL-c436t-d5e3de0934b8f8c36b7b8a61b52f5f10697849023672439cdabc93f94a249e793</originalsourceid><addsrcrecordid>eNp1kE1LxDAQhoMo7rr6A7xI8eIpOvnYNDmKuCqseFHwFtI21Szbdk1SZP-9KV0VBHNIGOaZd8KD0CmBSwKQXwUAqgQGAphwITHfQ1PCWY6JgNd9NAWSUyzTNUFHIawg1ULAIZpQ4EC45FP0uLAmuMKtXdxmIfbVNuvqLNjGYdPHrjHRVlmTmN7bxrYxDO3atW_WZ6vOtTELG1Pa7NNV8T0co4ParIM92b0z9LK4fb65x8unu4eb6yUuORMRV3PLKguK8ULWsmSiyAtpBCnmtJ7XBITKJVdAmcgpZ6qsTFEqVituKFc2V2yGLsbcje8-ehuiblwo7XptWtv1QUvFlCRE0USe_yFXXe_b9LkB4pAOSxAZodJ3IXhb6413jfFbTUAPpvVoWsNQJ9Oap5mzXXBfNLb6mfhWmwA6AiG1Bl-_m_9P_QI2e4go</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>893400003</pqid></control><display><type>article</type><title>Feasibility study of semi-automated measurements of finger joint space widths</title><source>Springer Nature:Jisc Collections:Springer Nature Read and Publish 2023-2025: Springer Reading List</source><creator>Pfeil, Alexander ; Sommerfeld, Julia ; Fröber, Rosemarie ; Lehmann, Gabriele ; Malich, Ansgar ; Hansch, Andreas ; Wolf, Gunter ; Böttcher, Joachim</creator><creatorcontrib>Pfeil, Alexander ; Sommerfeld, Julia ; Fröber, Rosemarie ; Lehmann, Gabriele ; Malich, Ansgar ; Hansch, Andreas ; Wolf, Gunter ; Böttcher, Joachim</creatorcontrib><description>The purpose of this study is to evaluate technical feasibility based on image capturing conditions (film-focus distance (FFD), film sensitivity, film brand, exposure level and tube voltage) that potentially alter radiographs and consequently may influence the semi-automated measurement of joint space distance (JSD) by computer-aided joint space analysis (CAJSA) in rheumatoid arthritis and osteoarthritis. The radiographs of a left hand (deceased man) were acquired under systematically changing image capturing conditions (exposure level: 4–8 mAs; FFD: 90–130 cm; film sensitivity: 200/400 and tube voltage: 40–52 kV with different image modalities: conventional radiographs, original digital radiographs, digital print-outs). All JSD-measurements were performed with the CAJSA-technology (Radiogrammetry Kit, Version 1.3.6; Sectra; Sweden) at the metacarpal-phalangeal articulation. JSD-analysis was not influenced by changes of FFD, exposure level, film sensitivity or film brand. JSD showed significant variation caused by tube voltage (conventional: CV = 1.913% for Agfa and CV = 2.448% for Kodak; digital: CV = 0.741% for Philips print-outs and CV = 0.620% with original digital images versus CV = 2.185% for Siemens print-outs and 0.951% with original digital images). Computer-aided joint space analysis for JSD-measurements is unaffected by the following image capturing parameters: film-focus distance, film sensitivity, film brand and exposure level. An influence of tube voltage was detected in a lesser extent for original digital images compared to the printed digital as well as conventional versions. Consequently, a standardized tube voltage is essential for accurate reproductions of CAJSA-measurements in rheumatoid arthritis and osteoarthritis.</description><identifier>ISSN: 0172-8172</identifier><identifier>EISSN: 1437-160X</identifier><identifier>DOI: 10.1007/s00296-010-1468-4</identifier><identifier>PMID: 20401484</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer-Verlag</publisher><subject>Arthritis, Rheumatoid - diagnostic imaging ; Arthrography - methods ; Arthrography - standards ; Cadaver ; Diagnosis, Computer-Assisted - methods ; Diagnosis, Computer-Assisted - standards ; Feasibility Studies ; Finger Joint - diagnostic imaging ; Humans ; Male ; Medicine ; Medicine & Public Health ; Original Article ; Osteoarthritis - diagnostic imaging ; Radiation Dosage ; Rheumatology ; X-Ray Film - standards</subject><ispartof>Rheumatology international, 2011-10, Vol.31 (10), p.1349-1354</ispartof><rights>Springer-Verlag 2010</rights><rights>Springer-Verlag 2011</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c436t-d5e3de0934b8f8c36b7b8a61b52f5f10697849023672439cdabc93f94a249e793</citedby><cites>FETCH-LOGICAL-c436t-d5e3de0934b8f8c36b7b8a61b52f5f10697849023672439cdabc93f94a249e793</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20401484$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pfeil, Alexander</creatorcontrib><creatorcontrib>Sommerfeld, Julia</creatorcontrib><creatorcontrib>Fröber, Rosemarie</creatorcontrib><creatorcontrib>Lehmann, Gabriele</creatorcontrib><creatorcontrib>Malich, Ansgar</creatorcontrib><creatorcontrib>Hansch, Andreas</creatorcontrib><creatorcontrib>Wolf, Gunter</creatorcontrib><creatorcontrib>Böttcher, Joachim</creatorcontrib><title>Feasibility study of semi-automated measurements of finger joint space widths</title><title>Rheumatology international</title><addtitle>Rheumatol Int</addtitle><addtitle>Rheumatol Int</addtitle><description>The purpose of this study is to evaluate technical feasibility based on image capturing conditions (film-focus distance (FFD), film sensitivity, film brand, exposure level and tube voltage) that potentially alter radiographs and consequently may influence the semi-automated measurement of joint space distance (JSD) by computer-aided joint space analysis (CAJSA) in rheumatoid arthritis and osteoarthritis. The radiographs of a left hand (deceased man) were acquired under systematically changing image capturing conditions (exposure level: 4–8 mAs; FFD: 90–130 cm; film sensitivity: 200/400 and tube voltage: 40–52 kV with different image modalities: conventional radiographs, original digital radiographs, digital print-outs). All JSD-measurements were performed with the CAJSA-technology (Radiogrammetry Kit, Version 1.3.6; Sectra; Sweden) at the metacarpal-phalangeal articulation. JSD-analysis was not influenced by changes of FFD, exposure level, film sensitivity or film brand. JSD showed significant variation caused by tube voltage (conventional: CV = 1.913% for Agfa and CV = 2.448% for Kodak; digital: CV = 0.741% for Philips print-outs and CV = 0.620% with original digital images versus CV = 2.185% for Siemens print-outs and 0.951% with original digital images). Computer-aided joint space analysis for JSD-measurements is unaffected by the following image capturing parameters: film-focus distance, film sensitivity, film brand and exposure level. An influence of tube voltage was detected in a lesser extent for original digital images compared to the printed digital as well as conventional versions. Consequently, a standardized tube voltage is essential for accurate reproductions of CAJSA-measurements in rheumatoid arthritis and osteoarthritis.</description><subject>Arthritis, Rheumatoid - diagnostic imaging</subject><subject>Arthrography - methods</subject><subject>Arthrography - standards</subject><subject>Cadaver</subject><subject>Diagnosis, Computer-Assisted - methods</subject><subject>Diagnosis, Computer-Assisted - standards</subject><subject>Feasibility Studies</subject><subject>Finger Joint - diagnostic imaging</subject><subject>Humans</subject><subject>Male</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Original Article</subject><subject>Osteoarthritis - diagnostic imaging</subject><subject>Radiation Dosage</subject><subject>Rheumatology</subject><subject>X-Ray Film - standards</subject><issn>0172-8172</issn><issn>1437-160X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp1kE1LxDAQhoMo7rr6A7xI8eIpOvnYNDmKuCqseFHwFtI21Szbdk1SZP-9KV0VBHNIGOaZd8KD0CmBSwKQXwUAqgQGAphwITHfQ1PCWY6JgNd9NAWSUyzTNUFHIawg1ULAIZpQ4EC45FP0uLAmuMKtXdxmIfbVNuvqLNjGYdPHrjHRVlmTmN7bxrYxDO3atW_WZ6vOtTELG1Pa7NNV8T0co4ParIM92b0z9LK4fb65x8unu4eb6yUuORMRV3PLKguK8ULWsmSiyAtpBCnmtJ7XBITKJVdAmcgpZ6qsTFEqVituKFc2V2yGLsbcje8-ehuiblwo7XptWtv1QUvFlCRE0USe_yFXXe_b9LkB4pAOSxAZodJ3IXhb6413jfFbTUAPpvVoWsNQJ9Oap5mzXXBfNLb6mfhWmwA6AiG1Bl-_m_9P_QI2e4go</recordid><startdate>20111001</startdate><enddate>20111001</enddate><creator>Pfeil, Alexander</creator><creator>Sommerfeld, Julia</creator><creator>Fröber, Rosemarie</creator><creator>Lehmann, Gabriele</creator><creator>Malich, Ansgar</creator><creator>Hansch, Andreas</creator><creator>Wolf, Gunter</creator><creator>Böttcher, Joachim</creator><general>Springer-Verlag</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20111001</creationdate><title>Feasibility study of semi-automated measurements of finger joint space widths</title><author>Pfeil, Alexander ; Sommerfeld, Julia ; Fröber, Rosemarie ; Lehmann, Gabriele ; Malich, Ansgar ; Hansch, Andreas ; Wolf, Gunter ; Böttcher, Joachim</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c436t-d5e3de0934b8f8c36b7b8a61b52f5f10697849023672439cdabc93f94a249e793</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Arthritis, Rheumatoid - diagnostic imaging</topic><topic>Arthrography - methods</topic><topic>Arthrography - standards</topic><topic>Cadaver</topic><topic>Diagnosis, Computer-Assisted - methods</topic><topic>Diagnosis, Computer-Assisted - standards</topic><topic>Feasibility Studies</topic><topic>Finger Joint - diagnostic imaging</topic><topic>Humans</topic><topic>Male</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Original Article</topic><topic>Osteoarthritis - diagnostic imaging</topic><topic>Radiation Dosage</topic><topic>Rheumatology</topic><topic>X-Ray Film - standards</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pfeil, Alexander</creatorcontrib><creatorcontrib>Sommerfeld, Julia</creatorcontrib><creatorcontrib>Fröber, Rosemarie</creatorcontrib><creatorcontrib>Lehmann, Gabriele</creatorcontrib><creatorcontrib>Malich, Ansgar</creatorcontrib><creatorcontrib>Hansch, Andreas</creatorcontrib><creatorcontrib>Wolf, Gunter</creatorcontrib><creatorcontrib>Böttcher, Joachim</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Rheumatology international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pfeil, Alexander</au><au>Sommerfeld, Julia</au><au>Fröber, Rosemarie</au><au>Lehmann, Gabriele</au><au>Malich, Ansgar</au><au>Hansch, Andreas</au><au>Wolf, Gunter</au><au>Böttcher, Joachim</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Feasibility study of semi-automated measurements of finger joint space widths</atitle><jtitle>Rheumatology international</jtitle><stitle>Rheumatol Int</stitle><addtitle>Rheumatol Int</addtitle><date>2011-10-01</date><risdate>2011</risdate><volume>31</volume><issue>10</issue><spage>1349</spage><epage>1354</epage><pages>1349-1354</pages><issn>0172-8172</issn><eissn>1437-160X</eissn><abstract>The purpose of this study is to evaluate technical feasibility based on image capturing conditions (film-focus distance (FFD), film sensitivity, film brand, exposure level and tube voltage) that potentially alter radiographs and consequently may influence the semi-automated measurement of joint space distance (JSD) by computer-aided joint space analysis (CAJSA) in rheumatoid arthritis and osteoarthritis. The radiographs of a left hand (deceased man) were acquired under systematically changing image capturing conditions (exposure level: 4–8 mAs; FFD: 90–130 cm; film sensitivity: 200/400 and tube voltage: 40–52 kV with different image modalities: conventional radiographs, original digital radiographs, digital print-outs). All JSD-measurements were performed with the CAJSA-technology (Radiogrammetry Kit, Version 1.3.6; Sectra; Sweden) at the metacarpal-phalangeal articulation. JSD-analysis was not influenced by changes of FFD, exposure level, film sensitivity or film brand. JSD showed significant variation caused by tube voltage (conventional: CV = 1.913% for Agfa and CV = 2.448% for Kodak; digital: CV = 0.741% for Philips print-outs and CV = 0.620% with original digital images versus CV = 2.185% for Siemens print-outs and 0.951% with original digital images). Computer-aided joint space analysis for JSD-measurements is unaffected by the following image capturing parameters: film-focus distance, film sensitivity, film brand and exposure level. An influence of tube voltage was detected in a lesser extent for original digital images compared to the printed digital as well as conventional versions. Consequently, a standardized tube voltage is essential for accurate reproductions of CAJSA-measurements in rheumatoid arthritis and osteoarthritis.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer-Verlag</pub><pmid>20401484</pmid><doi>10.1007/s00296-010-1468-4</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0172-8172 |
ispartof | Rheumatology international, 2011-10, Vol.31 (10), p.1349-1354 |
issn | 0172-8172 1437-160X |
language | eng |
recordid | cdi_proquest_miscellaneous_893981192 |
source | Springer Nature:Jisc Collections:Springer Nature Read and Publish 2023-2025: Springer Reading List |
subjects | Arthritis, Rheumatoid - diagnostic imaging Arthrography - methods Arthrography - standards Cadaver Diagnosis, Computer-Assisted - methods Diagnosis, Computer-Assisted - standards Feasibility Studies Finger Joint - diagnostic imaging Humans Male Medicine Medicine & Public Health Original Article Osteoarthritis - diagnostic imaging Radiation Dosage Rheumatology X-Ray Film - standards |
title | Feasibility study of semi-automated measurements of finger joint space widths |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T03%3A48%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Feasibility%20study%20of%20semi-automated%20measurements%20of%20finger%20joint%20space%20widths&rft.jtitle=Rheumatology%20international&rft.au=Pfeil,%20Alexander&rft.date=2011-10-01&rft.volume=31&rft.issue=10&rft.spage=1349&rft.epage=1354&rft.pages=1349-1354&rft.issn=0172-8172&rft.eissn=1437-160X&rft_id=info:doi/10.1007/s00296-010-1468-4&rft_dat=%3Cproquest_cross%3E2465072241%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c436t-d5e3de0934b8f8c36b7b8a61b52f5f10697849023672439cdabc93f94a249e793%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=893400003&rft_id=info:pmid/20401484&rfr_iscdi=true |