Loading…
The EUROP total knee prosthesis: A ten-year follow-up study of a posterior cruciate-retaining design
Summary Introduction The success of total knee arthroplasty is measured by pain relief, functional recovery, and implant survival duration. The aim of the present study was to evaluate the long-term clinical, functional and radiological results of the posterior cruciate ligament (PCL)-retaining fixe...
Saved in:
Published in: | Orthopaedics & traumatology, surgery & research surgery & research, 2011-10, Vol.97 (6), p.639-647 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Summary Introduction The success of total knee arthroplasty is measured by pain relief, functional recovery, and implant survival duration. The aim of the present study was to evaluate the long-term clinical, functional and radiological results of the posterior cruciate ligament (PCL)-retaining fixed bearing EUROP implant. Hypothesis The long-term results of EUROP implants are similar to those reported with comparable prostheses. Patients and methods We performed a prospective, monocentric study of a series of 121 cemented EUROP total knee arthroplasties, implanted between 1994 and 1996 in 117 patients mean age 73. A clinical and radiological evaluation was performed at 10 years of follow-up according to the International Knee Society (IKS) score. Twenty-three patients died, 14 were lost to follow-up, 43 underwent clinical and radiological evaluation and 37 were questioned by telephone. Results The preoperative IKS knee score was 31 points (0–60) and increased to 88 points (30–98) at final follow-up, IKS function increased from 40 (0–90) to 80 points (25–100). Radiolucencies were observed in 56% of the condyles and 60% of tibial plates. Ninety-three percent of these radiolucent lines were less than 1 mm wide. Three patients underwent revision TKA at 32 months, eight and 11 years respectively. Global implant survival was 99% at five years, 97.8% at 10 years and 95.8% at 12 years. Discussion The clinical and radiological results of the cruciate-retaining fixed bearing EUROP total knee arthroplasties, with three cases of revision arthroplasty at 12 years of follow-up are satisfactory and comparable to similar implants. Level of evidence Level IV; prospective study. |
---|---|
ISSN: | 1877-0568 1877-0568 |
DOI: | 10.1016/j.otsr.2011.02.013 |