Loading…

Causes of damage to baffle pipes in high-pressure drum boilers at the Ust’-Ilimsk heat and electric power plant

The causes of damage to the baffle pipes in BKZ-420-140PT-2 high-pressure drum boilers during combustion of Irsha-Borodin and Zheronskii coals are analyzed. Damage to the salt module pipes was caused by the buildup of internal sediments and untimely chemical washing of the baffles. Flaws and bulging...

Full description

Saved in:
Bibliographic Details
Published in:Power technology and engineering 2008-11, Vol.42 (6), p.344-348
Main Authors: Belyakov, I. I., Breus, V. I., Litvinova, L. A., Poloskov, V. A.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The causes of damage to the baffle pipes in BKZ-420-140PT-2 high-pressure drum boilers during combustion of Irsha-Borodin and Zheronskii coals are analyzed. Damage to the salt module pipes was caused by the buildup of internal sediments and untimely chemical washing of the baffles. Flaws and bulging of the clean module pipes in the constriction region are caused by insufficient flow velocities in the 76/62-mm diameter pipes and high thermal loads during burning of Zheronskii coal. The fundamental solution for increasing the reliability of the boilers is to rebuild them with conversion to dry slag removal.
ISSN:1570-145X
1570-1468