Causes of damage to baffle pipes in high-pressure drum boilers at the Ust’-Ilimsk heat and electric power plant
The causes of damage to the baffle pipes in BKZ-420-140PT-2 high-pressure drum boilers during combustion of Irsha-Borodin and Zheronskii coals are analyzed. Damage to the salt module pipes was caused by the buildup of internal sediments and untimely chemical washing of the baffles. Flaws and bulging...
Saved in:
Published in: | Power technology and engineering 2008-11, Vol.42 (6), p.344-348 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The causes of damage to the baffle pipes in BKZ-420-140PT-2 high-pressure drum boilers during combustion of Irsha-Borodin and Zheronskii coals are analyzed. Damage to the salt module pipes was caused by the buildup of internal sediments and untimely chemical washing of the baffles. Flaws and bulging of the clean module pipes in the constriction region are caused by insufficient flow velocities in the 76/62-mm diameter pipes and high thermal loads during burning of Zheronskii coal. The fundamental solution for increasing the reliability of the boilers is to rebuild them with conversion to dry slag removal. |
---|---|