Loading…
Randomized controlled, multicentre clinical trial comparing a dual‐probe ultrasonic lithotrite with a single‐probe lithotrite for percutaneous nephrolithotomy
Study Type – Therapy (case series) Level of Evidence 4 What’s known on the subject? and What does the study add? Studies have indicated that not all ultrasonic lithotripters are created equal when it comes to efficiency of stone fragmentation and removal. To improve the efficiency of stone fragmenta...
Saved in:
Published in: | BJU international 2011-03, Vol.107 (5), p.824-828 |
---|---|
Main Authors: | , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c5637-d8dbb9ac1d423d042ab92fe94e1d70af9bf68ebed08ed8fd43cb055e8661ff113 |
---|---|
cites | cdi_FETCH-LOGICAL-c5637-d8dbb9ac1d423d042ab92fe94e1d70af9bf68ebed08ed8fd43cb055e8661ff113 |
container_end_page | 828 |
container_issue | 5 |
container_start_page | 824 |
container_title | BJU international |
container_volume | 107 |
creator | Krambeck, Amy E. Miller, Nicole L. Humphreys, Mitchell R. Nakada, Stephen Y. Denstedt, John D. Razvi, Hassan Preminger, Glenn M. Nadler, Robert B. Matlaga, Brian R. Paterson, Ryan F. Chew, Ben H. Munch, Larry C. Handa, Shelly E. Lingeman, James E. |
description | Study Type – Therapy (case series)
Level of Evidence 4
What’s known on the subject? and What does the study add?
Studies have indicated that not all ultrasonic lithotripters are created equal when it comes to efficiency of stone fragmentation and removal. To improve the efficiency of stone fragmentation and removal, combination pneumatic and ultrasonic devices have been developed. This study demonstrates that one available combination device, the Cyberwand, did not decrease the time to removal of the target stone nor did it increase the stone free rate compared to a standard ultrasonic lithotripter.
OBJECTIVES
• To compare the Cyberwand (Gyrus/ACMI, Southborough, MA, USA), a dual‐probe ultrasonic lithotrite, with a single‐probe ultrasonic lithotrite.
• The Cyberwand incorporates coaxial high‐ and low‐frequency ultrasonic probes that work synergistically.
PATIENTS AND METHODS
• An institutional review board‐approved, multicentre, randomized controlled trial to compare the Cyberwand to the Olympus LUS‐II (Olympus America, Inc., Melville, NY, USA) single‐probe lithotrite was performed.
• Patients undergoing a percutaneous nephrolithotomy (PCNL) with a target stone >2 cm in diameter were eligible for the study.
• The primary outcome was the time to removal of the targeted stone.
RESULTS
• A total of 57 PCNLs were performed after randomization: 25 Cyberwand and 32 LUS‐II.
• There was no difference (P > 0.05) observed between the two devices for target stone surface area (Cyberwand 526.6 cm3 vs LUS‐II 540.1 cm3), time to clearance of target stone (Cyberwand 15.8 min vs LUS‐II 14.2 min) and target stone clearance rate (Cyberwand 61.9 mm2/min vs LUS‐II 75.8 mm2/min).
• Of the patients with stone analysis, hard stones (calcium oxalate monohydrate, brushite and cystine) were noted in 14 (56.0%) of the 25 Cyberwand and 18 (62.1%) of the 29 LUS‐II patients.
• Fifteen of the 25 (60.0%) Cyberwand and 20 of the 32 (62.5%) LUS‐II patients were stone‐free after the initial PCNL.
• Those patients not rendered stone‐free went on to receive a secondary PCNL.
• Device malfunction occurred in eight of 25(32.0%) Cyberwand and five of 32 (15.6%) LUS II patients.
• Complications were similar in both treatment groups.
CONCLUSION
• No appreciable difference between the dual‐probe Cyberwand and the standard ultrasonic Olympus LUS‐II lithotrites can be identified. |
doi_str_mv | 10.1111/j.1464-410X.2010.09567.x |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_904471930</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1911962154</sourcerecordid><originalsourceid>FETCH-LOGICAL-c5637-d8dbb9ac1d423d042ab92fe94e1d70af9bf68ebed08ed8fd43cb055e8661ff113</originalsourceid><addsrcrecordid>eNqN0c1u1DAQB_AIgegHvAKyhBCX7mInthMfOJSKT1VCQlTiZjn2hHrlxIudqF1OPALPwKPxJEy62wVxgRyS0eQ3zkT_oiCMLhlez1ZLxiVfcEY_LUuKXaqErJfXd4rD_Yu7tzVV8qA4ynlFKTakuF8clKwSQjXlYfHjgxlc7P1XcMTGYUwxBHAnpJ_C6C1gA4gNfvDWBDImj3cb-7VJfvhMDHGTCT-_fV-n2ALBkWRyREuCHy8j8hHIFZYoMw4E2Ns_QBcTWUOy02gGiFMmA6wvcY8bEfvNg-JeZ0KGh7vncXHx6uXHszeL8_ev356dni-skFW9cI1rW2Usc7ysHOWlaVXZgeLAXE1Np9pONtCCow24pnO8si0VAhopWdcxVh0XT7fn4oZfJsij7n22EMJ2La0o5zVTFf2nbAQXktNaonz8l1zFKQ34G5opxpQsmeComq2yKeacoNPr5HuTNppRPQeuV3rOUs-56jlwfRO4vsbRR7sPTG0Pbj94mzCCJztgMmbYJTNYn3-7StFGsgrd86278gE2_72AfvHuYq6qXw76zj4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1911962154</pqid></control><display><type>article</type><title>Randomized controlled, multicentre clinical trial comparing a dual‐probe ultrasonic lithotrite with a single‐probe lithotrite for percutaneous nephrolithotomy</title><source>Wiley</source><creator>Krambeck, Amy E. ; Miller, Nicole L. ; Humphreys, Mitchell R. ; Nakada, Stephen Y. ; Denstedt, John D. ; Razvi, Hassan ; Preminger, Glenn M. ; Nadler, Robert B. ; Matlaga, Brian R. ; Paterson, Ryan F. ; Chew, Ben H. ; Munch, Larry C. ; Handa, Shelly E. ; Lingeman, James E.</creator><creatorcontrib>Krambeck, Amy E. ; Miller, Nicole L. ; Humphreys, Mitchell R. ; Nakada, Stephen Y. ; Denstedt, John D. ; Razvi, Hassan ; Preminger, Glenn M. ; Nadler, Robert B. ; Matlaga, Brian R. ; Paterson, Ryan F. ; Chew, Ben H. ; Munch, Larry C. ; Handa, Shelly E. ; Lingeman, James E.</creatorcontrib><description>Study Type – Therapy (case series)
Level of Evidence 4
What’s known on the subject? and What does the study add?
Studies have indicated that not all ultrasonic lithotripters are created equal when it comes to efficiency of stone fragmentation and removal. To improve the efficiency of stone fragmentation and removal, combination pneumatic and ultrasonic devices have been developed. This study demonstrates that one available combination device, the Cyberwand, did not decrease the time to removal of the target stone nor did it increase the stone free rate compared to a standard ultrasonic lithotripter.
OBJECTIVES
• To compare the Cyberwand (Gyrus/ACMI, Southborough, MA, USA), a dual‐probe ultrasonic lithotrite, with a single‐probe ultrasonic lithotrite.
• The Cyberwand incorporates coaxial high‐ and low‐frequency ultrasonic probes that work synergistically.
PATIENTS AND METHODS
• An institutional review board‐approved, multicentre, randomized controlled trial to compare the Cyberwand to the Olympus LUS‐II (Olympus America, Inc., Melville, NY, USA) single‐probe lithotrite was performed.
• Patients undergoing a percutaneous nephrolithotomy (PCNL) with a target stone >2 cm in diameter were eligible for the study.
• The primary outcome was the time to removal of the targeted stone.
RESULTS
• A total of 57 PCNLs were performed after randomization: 25 Cyberwand and 32 LUS‐II.
• There was no difference (P > 0.05) observed between the two devices for target stone surface area (Cyberwand 526.6 cm3 vs LUS‐II 540.1 cm3), time to clearance of target stone (Cyberwand 15.8 min vs LUS‐II 14.2 min) and target stone clearance rate (Cyberwand 61.9 mm2/min vs LUS‐II 75.8 mm2/min).
• Of the patients with stone analysis, hard stones (calcium oxalate monohydrate, brushite and cystine) were noted in 14 (56.0%) of the 25 Cyberwand and 18 (62.1%) of the 29 LUS‐II patients.
• Fifteen of the 25 (60.0%) Cyberwand and 20 of the 32 (62.5%) LUS‐II patients were stone‐free after the initial PCNL.
• Those patients not rendered stone‐free went on to receive a secondary PCNL.
• Device malfunction occurred in eight of 25(32.0%) Cyberwand and five of 32 (15.6%) LUS II patients.
• Complications were similar in both treatment groups.
CONCLUSION
• No appreciable difference between the dual‐probe Cyberwand and the standard ultrasonic Olympus LUS‐II lithotrites can be identified.</description><identifier>ISSN: 1464-4096</identifier><identifier>EISSN: 1464-410X</identifier><identifier>DOI: 10.1111/j.1464-410X.2010.09567.x</identifier><identifier>PMID: 21355982</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>Adult ; Aged ; Biological and medical sciences ; Calcium oxalate ; Clinical trials ; Epidemiologic Methods ; Equipment Design ; Equipment Failure ; Female ; Humans ; kidney ; kidney calculi ; Kidney Calculi - surgery ; Kidney stones ; lithotripsy ; lithotrite ; Male ; Medical sciences ; Middle Aged ; Nephrology. Urinary tract diseases ; nephrostomy ; Nephrostomy, Percutaneous - adverse effects ; Nephrostomy, Percutaneous - instrumentation ; Nephrostomy, Percutaneous - methods ; Oxalic acid ; percutaneous ; Postoperative Complications - etiology ; Probes ; Surface area ; Ultrasonics ; Urinary lithiasis ; Young Adult</subject><ispartof>BJU international, 2011-03, Vol.107 (5), p.824-828</ispartof><rights>2010 THE AUTHORS. BJU INTERNATIONAL © 2010 BJU INTERNATIONAL</rights><rights>2015 INIST-CNRS</rights><rights>2010 THE AUTHORS. BJU INTERNATIONAL © 2010 BJU INTERNATIONAL.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c5637-d8dbb9ac1d423d042ab92fe94e1d70af9bf68ebed08ed8fd43cb055e8661ff113</citedby><cites>FETCH-LOGICAL-c5637-d8dbb9ac1d423d042ab92fe94e1d70af9bf68ebed08ed8fd43cb055e8661ff113</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=23908613$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21355982$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Krambeck, Amy E.</creatorcontrib><creatorcontrib>Miller, Nicole L.</creatorcontrib><creatorcontrib>Humphreys, Mitchell R.</creatorcontrib><creatorcontrib>Nakada, Stephen Y.</creatorcontrib><creatorcontrib>Denstedt, John D.</creatorcontrib><creatorcontrib>Razvi, Hassan</creatorcontrib><creatorcontrib>Preminger, Glenn M.</creatorcontrib><creatorcontrib>Nadler, Robert B.</creatorcontrib><creatorcontrib>Matlaga, Brian R.</creatorcontrib><creatorcontrib>Paterson, Ryan F.</creatorcontrib><creatorcontrib>Chew, Ben H.</creatorcontrib><creatorcontrib>Munch, Larry C.</creatorcontrib><creatorcontrib>Handa, Shelly E.</creatorcontrib><creatorcontrib>Lingeman, James E.</creatorcontrib><title>Randomized controlled, multicentre clinical trial comparing a dual‐probe ultrasonic lithotrite with a single‐probe lithotrite for percutaneous nephrolithotomy</title><title>BJU international</title><addtitle>BJU Int</addtitle><description>Study Type – Therapy (case series)
Level of Evidence 4
What’s known on the subject? and What does the study add?
Studies have indicated that not all ultrasonic lithotripters are created equal when it comes to efficiency of stone fragmentation and removal. To improve the efficiency of stone fragmentation and removal, combination pneumatic and ultrasonic devices have been developed. This study demonstrates that one available combination device, the Cyberwand, did not decrease the time to removal of the target stone nor did it increase the stone free rate compared to a standard ultrasonic lithotripter.
OBJECTIVES
• To compare the Cyberwand (Gyrus/ACMI, Southborough, MA, USA), a dual‐probe ultrasonic lithotrite, with a single‐probe ultrasonic lithotrite.
• The Cyberwand incorporates coaxial high‐ and low‐frequency ultrasonic probes that work synergistically.
PATIENTS AND METHODS
• An institutional review board‐approved, multicentre, randomized controlled trial to compare the Cyberwand to the Olympus LUS‐II (Olympus America, Inc., Melville, NY, USA) single‐probe lithotrite was performed.
• Patients undergoing a percutaneous nephrolithotomy (PCNL) with a target stone >2 cm in diameter were eligible for the study.
• The primary outcome was the time to removal of the targeted stone.
RESULTS
• A total of 57 PCNLs were performed after randomization: 25 Cyberwand and 32 LUS‐II.
• There was no difference (P > 0.05) observed between the two devices for target stone surface area (Cyberwand 526.6 cm3 vs LUS‐II 540.1 cm3), time to clearance of target stone (Cyberwand 15.8 min vs LUS‐II 14.2 min) and target stone clearance rate (Cyberwand 61.9 mm2/min vs LUS‐II 75.8 mm2/min).
• Of the patients with stone analysis, hard stones (calcium oxalate monohydrate, brushite and cystine) were noted in 14 (56.0%) of the 25 Cyberwand and 18 (62.1%) of the 29 LUS‐II patients.
• Fifteen of the 25 (60.0%) Cyberwand and 20 of the 32 (62.5%) LUS‐II patients were stone‐free after the initial PCNL.
• Those patients not rendered stone‐free went on to receive a secondary PCNL.
• Device malfunction occurred in eight of 25(32.0%) Cyberwand and five of 32 (15.6%) LUS II patients.
• Complications were similar in both treatment groups.
CONCLUSION
• No appreciable difference between the dual‐probe Cyberwand and the standard ultrasonic Olympus LUS‐II lithotrites can be identified.</description><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Calcium oxalate</subject><subject>Clinical trials</subject><subject>Epidemiologic Methods</subject><subject>Equipment Design</subject><subject>Equipment Failure</subject><subject>Female</subject><subject>Humans</subject><subject>kidney</subject><subject>kidney calculi</subject><subject>Kidney Calculi - surgery</subject><subject>Kidney stones</subject><subject>lithotripsy</subject><subject>lithotrite</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Nephrology. Urinary tract diseases</subject><subject>nephrostomy</subject><subject>Nephrostomy, Percutaneous - adverse effects</subject><subject>Nephrostomy, Percutaneous - instrumentation</subject><subject>Nephrostomy, Percutaneous - methods</subject><subject>Oxalic acid</subject><subject>percutaneous</subject><subject>Postoperative Complications - etiology</subject><subject>Probes</subject><subject>Surface area</subject><subject>Ultrasonics</subject><subject>Urinary lithiasis</subject><subject>Young Adult</subject><issn>1464-4096</issn><issn>1464-410X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNqN0c1u1DAQB_AIgegHvAKyhBCX7mInthMfOJSKT1VCQlTiZjn2hHrlxIudqF1OPALPwKPxJEy62wVxgRyS0eQ3zkT_oiCMLhlez1ZLxiVfcEY_LUuKXaqErJfXd4rD_Yu7tzVV8qA4ynlFKTakuF8clKwSQjXlYfHjgxlc7P1XcMTGYUwxBHAnpJ_C6C1gA4gNfvDWBDImj3cb-7VJfvhMDHGTCT-_fV-n2ALBkWRyREuCHy8j8hHIFZYoMw4E2Ns_QBcTWUOy02gGiFMmA6wvcY8bEfvNg-JeZ0KGh7vncXHx6uXHszeL8_ev356dni-skFW9cI1rW2Usc7ysHOWlaVXZgeLAXE1Np9pONtCCow24pnO8si0VAhopWdcxVh0XT7fn4oZfJsij7n22EMJ2La0o5zVTFf2nbAQXktNaonz8l1zFKQ34G5opxpQsmeComq2yKeacoNPr5HuTNppRPQeuV3rOUs-56jlwfRO4vsbRR7sPTG0Pbj94mzCCJztgMmbYJTNYn3-7StFGsgrd86278gE2_72AfvHuYq6qXw76zj4</recordid><startdate>201103</startdate><enddate>201103</enddate><creator>Krambeck, Amy E.</creator><creator>Miller, Nicole L.</creator><creator>Humphreys, Mitchell R.</creator><creator>Nakada, Stephen Y.</creator><creator>Denstedt, John D.</creator><creator>Razvi, Hassan</creator><creator>Preminger, Glenn M.</creator><creator>Nadler, Robert B.</creator><creator>Matlaga, Brian R.</creator><creator>Paterson, Ryan F.</creator><creator>Chew, Ben H.</creator><creator>Munch, Larry C.</creator><creator>Handa, Shelly E.</creator><creator>Lingeman, James E.</creator><general>Blackwell Publishing Ltd</general><general>Wiley-Blackwell</general><general>Wiley Subscription Services, Inc</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QP</scope><scope>7X8</scope></search><sort><creationdate>201103</creationdate><title>Randomized controlled, multicentre clinical trial comparing a dual‐probe ultrasonic lithotrite with a single‐probe lithotrite for percutaneous nephrolithotomy</title><author>Krambeck, Amy E. ; Miller, Nicole L. ; Humphreys, Mitchell R. ; Nakada, Stephen Y. ; Denstedt, John D. ; Razvi, Hassan ; Preminger, Glenn M. ; Nadler, Robert B. ; Matlaga, Brian R. ; Paterson, Ryan F. ; Chew, Ben H. ; Munch, Larry C. ; Handa, Shelly E. ; Lingeman, James E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c5637-d8dbb9ac1d423d042ab92fe94e1d70af9bf68ebed08ed8fd43cb055e8661ff113</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Calcium oxalate</topic><topic>Clinical trials</topic><topic>Epidemiologic Methods</topic><topic>Equipment Design</topic><topic>Equipment Failure</topic><topic>Female</topic><topic>Humans</topic><topic>kidney</topic><topic>kidney calculi</topic><topic>Kidney Calculi - surgery</topic><topic>Kidney stones</topic><topic>lithotripsy</topic><topic>lithotrite</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Nephrology. Urinary tract diseases</topic><topic>nephrostomy</topic><topic>Nephrostomy, Percutaneous - adverse effects</topic><topic>Nephrostomy, Percutaneous - instrumentation</topic><topic>Nephrostomy, Percutaneous - methods</topic><topic>Oxalic acid</topic><topic>percutaneous</topic><topic>Postoperative Complications - etiology</topic><topic>Probes</topic><topic>Surface area</topic><topic>Ultrasonics</topic><topic>Urinary lithiasis</topic><topic>Young Adult</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Krambeck, Amy E.</creatorcontrib><creatorcontrib>Miller, Nicole L.</creatorcontrib><creatorcontrib>Humphreys, Mitchell R.</creatorcontrib><creatorcontrib>Nakada, Stephen Y.</creatorcontrib><creatorcontrib>Denstedt, John D.</creatorcontrib><creatorcontrib>Razvi, Hassan</creatorcontrib><creatorcontrib>Preminger, Glenn M.</creatorcontrib><creatorcontrib>Nadler, Robert B.</creatorcontrib><creatorcontrib>Matlaga, Brian R.</creatorcontrib><creatorcontrib>Paterson, Ryan F.</creatorcontrib><creatorcontrib>Chew, Ben H.</creatorcontrib><creatorcontrib>Munch, Larry C.</creatorcontrib><creatorcontrib>Handa, Shelly E.</creatorcontrib><creatorcontrib>Lingeman, James E.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>BJU international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Krambeck, Amy E.</au><au>Miller, Nicole L.</au><au>Humphreys, Mitchell R.</au><au>Nakada, Stephen Y.</au><au>Denstedt, John D.</au><au>Razvi, Hassan</au><au>Preminger, Glenn M.</au><au>Nadler, Robert B.</au><au>Matlaga, Brian R.</au><au>Paterson, Ryan F.</au><au>Chew, Ben H.</au><au>Munch, Larry C.</au><au>Handa, Shelly E.</au><au>Lingeman, James E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Randomized controlled, multicentre clinical trial comparing a dual‐probe ultrasonic lithotrite with a single‐probe lithotrite for percutaneous nephrolithotomy</atitle><jtitle>BJU international</jtitle><addtitle>BJU Int</addtitle><date>2011-03</date><risdate>2011</risdate><volume>107</volume><issue>5</issue><spage>824</spage><epage>828</epage><pages>824-828</pages><issn>1464-4096</issn><eissn>1464-410X</eissn><abstract>Study Type – Therapy (case series)
Level of Evidence 4
What’s known on the subject? and What does the study add?
Studies have indicated that not all ultrasonic lithotripters are created equal when it comes to efficiency of stone fragmentation and removal. To improve the efficiency of stone fragmentation and removal, combination pneumatic and ultrasonic devices have been developed. This study demonstrates that one available combination device, the Cyberwand, did not decrease the time to removal of the target stone nor did it increase the stone free rate compared to a standard ultrasonic lithotripter.
OBJECTIVES
• To compare the Cyberwand (Gyrus/ACMI, Southborough, MA, USA), a dual‐probe ultrasonic lithotrite, with a single‐probe ultrasonic lithotrite.
• The Cyberwand incorporates coaxial high‐ and low‐frequency ultrasonic probes that work synergistically.
PATIENTS AND METHODS
• An institutional review board‐approved, multicentre, randomized controlled trial to compare the Cyberwand to the Olympus LUS‐II (Olympus America, Inc., Melville, NY, USA) single‐probe lithotrite was performed.
• Patients undergoing a percutaneous nephrolithotomy (PCNL) with a target stone >2 cm in diameter were eligible for the study.
• The primary outcome was the time to removal of the targeted stone.
RESULTS
• A total of 57 PCNLs were performed after randomization: 25 Cyberwand and 32 LUS‐II.
• There was no difference (P > 0.05) observed between the two devices for target stone surface area (Cyberwand 526.6 cm3 vs LUS‐II 540.1 cm3), time to clearance of target stone (Cyberwand 15.8 min vs LUS‐II 14.2 min) and target stone clearance rate (Cyberwand 61.9 mm2/min vs LUS‐II 75.8 mm2/min).
• Of the patients with stone analysis, hard stones (calcium oxalate monohydrate, brushite and cystine) were noted in 14 (56.0%) of the 25 Cyberwand and 18 (62.1%) of the 29 LUS‐II patients.
• Fifteen of the 25 (60.0%) Cyberwand and 20 of the 32 (62.5%) LUS‐II patients were stone‐free after the initial PCNL.
• Those patients not rendered stone‐free went on to receive a secondary PCNL.
• Device malfunction occurred in eight of 25(32.0%) Cyberwand and five of 32 (15.6%) LUS II patients.
• Complications were similar in both treatment groups.
CONCLUSION
• No appreciable difference between the dual‐probe Cyberwand and the standard ultrasonic Olympus LUS‐II lithotrites can be identified.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>21355982</pmid><doi>10.1111/j.1464-410X.2010.09567.x</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1464-4096 |
ispartof | BJU international, 2011-03, Vol.107 (5), p.824-828 |
issn | 1464-4096 1464-410X |
language | eng |
recordid | cdi_proquest_miscellaneous_904471930 |
source | Wiley |
subjects | Adult Aged Biological and medical sciences Calcium oxalate Clinical trials Epidemiologic Methods Equipment Design Equipment Failure Female Humans kidney kidney calculi Kidney Calculi - surgery Kidney stones lithotripsy lithotrite Male Medical sciences Middle Aged Nephrology. Urinary tract diseases nephrostomy Nephrostomy, Percutaneous - adverse effects Nephrostomy, Percutaneous - instrumentation Nephrostomy, Percutaneous - methods Oxalic acid percutaneous Postoperative Complications - etiology Probes Surface area Ultrasonics Urinary lithiasis Young Adult |
title | Randomized controlled, multicentre clinical trial comparing a dual‐probe ultrasonic lithotrite with a single‐probe lithotrite for percutaneous nephrolithotomy |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T15%3A23%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Randomized%20controlled,%20multicentre%20clinical%20trial%20comparing%20a%20dual%E2%80%90probe%20ultrasonic%20lithotrite%20with%20a%20single%E2%80%90probe%20lithotrite%20for%20percutaneous%20nephrolithotomy&rft.jtitle=BJU%20international&rft.au=Krambeck,%20Amy%20E.&rft.date=2011-03&rft.volume=107&rft.issue=5&rft.spage=824&rft.epage=828&rft.pages=824-828&rft.issn=1464-4096&rft.eissn=1464-410X&rft_id=info:doi/10.1111/j.1464-410X.2010.09567.x&rft_dat=%3Cproquest_cross%3E1911962154%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c5637-d8dbb9ac1d423d042ab92fe94e1d70af9bf68ebed08ed8fd43cb055e8661ff113%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1911962154&rft_id=info:pmid/21355982&rfr_iscdi=true |