Characteristics of diode perveance and vircator output under various anode-cathode gap distances
When an electron beam is generated from a cathode, an electrode sheath plasma is also generated. Hence, the perveance of the diode is varied and changes the diode output characteristics. In our pulsed-power system "Chundoong," the perveance characteristics have been experimentally investig...
Saved in:
Published in: | IEEE transactions on plasma science 2002-10, Vol.30 (5), p.1728-1732 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | When an electron beam is generated from a cathode, an electrode sheath plasma is also generated. Hence, the perveance of the diode is varied and changes the diode output characteristics. In our pulsed-power system "Chundoong," the perveance characteristics have been experimentally investigated, from which the sheath-plasma expansion speed has been measured to be about 3 cm//spl mu/s inside the diode. It is shown that the sheath-plasma expansion inside the diode gives the influence on the electron-beam current density. The vircator microwave output has been shown to be sensitively dependent on the anode-cathode (A-K) gap distance. The highest microwave power occurs at the initial A-K gap distance d=4 mm with peak power of 200 MW and a frequency of about 5.5 GHz in this experiment. |
---|---|
ISSN: | 0093-3813 1939-9375 |
DOI: | 10.1109/TPS.2002.806615 |