Dual-energy digital radiography in the assessment of bone mechanical properties

At present, bone fragility and fracture risk are estimated with bone mineral density (BMD), measured by dual-energy x-ray absorptiometry (DXA). It is known that DXA-based BMD (BMD(DXA)) has a relationship with mechanical characteristics of bone. Dual-energy digital radiography (DEDR) has also been s...

Full description

Saved in:
Bibliographic Details
Published in:Physiological measurement 2012-01, Vol.33 (1), p.29-37
Main Authors: Toljamo, P S, Lammentausta, E, Pulkkinen, P, Tervonen, O, Jämsä, T, Nieminen, M T
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c300t-503940a0be87d11a103e31f3c51ba82637bbc14b253be32eebd735bb5afbca393
cites cdi_FETCH-LOGICAL-c300t-503940a0be87d11a103e31f3c51ba82637bbc14b253be32eebd735bb5afbca393
container_end_page 37
container_issue 1
container_start_page 29
container_title Physiological measurement
container_volume 33
creator Toljamo, P S
Lammentausta, E
Pulkkinen, P
Tervonen, O
Jämsä, T
Nieminen, M T
description At present, bone fragility and fracture risk are estimated with bone mineral density (BMD), measured by dual-energy x-ray absorptiometry (DXA). It is known that DXA-based BMD (BMD(DXA)) has a relationship with mechanical characteristics of bone. Dual-energy digital radiography (DEDR) has also been shown to be a potential method to determine BMD, but the ability of DEDR-based BMD (BMD(DEDR)) to predict bone mechanical properties is not yet known. In this study, we investigated the ability of BMD(DEDR) to predict the mechanical characteristics of bone. Reindeer femora (N = 50) were imaged at two different energies (79 and 100 kV(p)) using a clinical digital radiography system. BMD was determined in four regions from these images using the DXA calculation principle. Femora were mechanically tested using axial loading configuration. Mechanical parameters were correlated with the BMD(DEDR) and BMD(DXA) of the femoral neck (FNBMD(DEDR) and FNBMD(DXA)). FNBMD(DEDR) and FNBMD(DXA) both correlated moderately with mechanical parameters. The highest correlations were found with maximal load (r = 0.53 and r = 0.65, p < 0.01, respectively). No statistically significant differences were found between the correlation coefficients when comparing the FNBMD(DEDR) or FNBMD(DXA) values and mechanical parameters. The correlation coefficient between BMD(DEDR) and BMD(DXA) varied between r = 0.56 and 0.86 (p < 0.01) in different regions of the upper femur. In conclusion, BMD(DEDR) predicts the mechanical parameters of reindeer bone with similar accuracy as BMD(DXA).
doi_str_mv 10.1088/0967-3334/33/1/29
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_911949983</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>911949983</sourcerecordid><originalsourceid>FETCH-LOGICAL-c300t-503940a0be87d11a103e31f3c51ba82637bbc14b253be32eebd735bb5afbca393</originalsourceid><addsrcrecordid>eNo9kD1PwzAQhi0EoqXwA1hQNqYQny9O4hGVT6lSF5gtO7m0QfnCTob-exK1dLkb7n2fkx7G7oE_Ac-yiKskDRExjhAjiIS6YEvABMJEpuqSLc_3Bbvx_odzgEzIa7YQAmQiMFuy7cto6pBacrtDUFS7ajB14ExRdTtn-v0hqNpg2FNgvCfvG2qHoCsD27UUNJTvTVvlU6F3XU9uqMjfsqvS1J7uTnvFvt9ev9Yf4Wb7_rl-3oQ5cj6EkqOKueGWsrQAMMCREErMJViTiQRTa3OIrZBoCQWRLVKU1kpT2tygwhV7PHKn178j-UE3lc-prk1L3ei1AlCxUhlOSTgmc9d576jUvasa4w4auJ416lmTnjVNQ4MWM_3hRB9tQ8W58e8N_wCCO24z</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>911949983</pqid></control><display><type>article</type><title>Dual-energy digital radiography in the assessment of bone mechanical properties</title><source>Institute of Physics</source><creator>Toljamo, P S ; Lammentausta, E ; Pulkkinen, P ; Tervonen, O ; Jämsä, T ; Nieminen, M T</creator><creatorcontrib>Toljamo, P S ; Lammentausta, E ; Pulkkinen, P ; Tervonen, O ; Jämsä, T ; Nieminen, M T</creatorcontrib><description>At present, bone fragility and fracture risk are estimated with bone mineral density (BMD), measured by dual-energy x-ray absorptiometry (DXA). It is known that DXA-based BMD (BMD(DXA)) has a relationship with mechanical characteristics of bone. Dual-energy digital radiography (DEDR) has also been shown to be a potential method to determine BMD, but the ability of DEDR-based BMD (BMD(DEDR)) to predict bone mechanical properties is not yet known. In this study, we investigated the ability of BMD(DEDR) to predict the mechanical characteristics of bone. Reindeer femora (N = 50) were imaged at two different energies (79 and 100 kV(p)) using a clinical digital radiography system. BMD was determined in four regions from these images using the DXA calculation principle. Femora were mechanically tested using axial loading configuration. Mechanical parameters were correlated with the BMD(DEDR) and BMD(DXA) of the femoral neck (FNBMD(DEDR) and FNBMD(DXA)). FNBMD(DEDR) and FNBMD(DXA) both correlated moderately with mechanical parameters. The highest correlations were found with maximal load (r = 0.53 and r = 0.65, p &lt; 0.01, respectively). No statistically significant differences were found between the correlation coefficients when comparing the FNBMD(DEDR) or FNBMD(DXA) values and mechanical parameters. The correlation coefficient between BMD(DEDR) and BMD(DXA) varied between r = 0.56 and 0.86 (p &lt; 0.01) in different regions of the upper femur. In conclusion, BMD(DEDR) predicts the mechanical parameters of reindeer bone with similar accuracy as BMD(DXA).</description><identifier>ISSN: 0967-3334</identifier><identifier>EISSN: 1361-6579</identifier><identifier>DOI: 10.1088/0967-3334/33/1/29</identifier><identifier>PMID: 22156238</identifier><language>eng</language><publisher>England</publisher><subject>Absorptiometry, Photon - methods ; Animals ; Biomechanical Phenomena - physiology ; Bone Density - physiology ; Femur - diagnostic imaging ; Radiographic Image Enhancement - methods ; Reindeer</subject><ispartof>Physiological measurement, 2012-01, Vol.33 (1), p.29-37</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c300t-503940a0be87d11a103e31f3c51ba82637bbc14b253be32eebd735bb5afbca393</citedby><cites>FETCH-LOGICAL-c300t-503940a0be87d11a103e31f3c51ba82637bbc14b253be32eebd735bb5afbca393</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22156238$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Toljamo, P S</creatorcontrib><creatorcontrib>Lammentausta, E</creatorcontrib><creatorcontrib>Pulkkinen, P</creatorcontrib><creatorcontrib>Tervonen, O</creatorcontrib><creatorcontrib>Jämsä, T</creatorcontrib><creatorcontrib>Nieminen, M T</creatorcontrib><title>Dual-energy digital radiography in the assessment of bone mechanical properties</title><title>Physiological measurement</title><addtitle>Physiol Meas</addtitle><description>At present, bone fragility and fracture risk are estimated with bone mineral density (BMD), measured by dual-energy x-ray absorptiometry (DXA). It is known that DXA-based BMD (BMD(DXA)) has a relationship with mechanical characteristics of bone. Dual-energy digital radiography (DEDR) has also been shown to be a potential method to determine BMD, but the ability of DEDR-based BMD (BMD(DEDR)) to predict bone mechanical properties is not yet known. In this study, we investigated the ability of BMD(DEDR) to predict the mechanical characteristics of bone. Reindeer femora (N = 50) were imaged at two different energies (79 and 100 kV(p)) using a clinical digital radiography system. BMD was determined in four regions from these images using the DXA calculation principle. Femora were mechanically tested using axial loading configuration. Mechanical parameters were correlated with the BMD(DEDR) and BMD(DXA) of the femoral neck (FNBMD(DEDR) and FNBMD(DXA)). FNBMD(DEDR) and FNBMD(DXA) both correlated moderately with mechanical parameters. The highest correlations were found with maximal load (r = 0.53 and r = 0.65, p &lt; 0.01, respectively). No statistically significant differences were found between the correlation coefficients when comparing the FNBMD(DEDR) or FNBMD(DXA) values and mechanical parameters. The correlation coefficient between BMD(DEDR) and BMD(DXA) varied between r = 0.56 and 0.86 (p &lt; 0.01) in different regions of the upper femur. In conclusion, BMD(DEDR) predicts the mechanical parameters of reindeer bone with similar accuracy as BMD(DXA).</description><subject>Absorptiometry, Photon - methods</subject><subject>Animals</subject><subject>Biomechanical Phenomena - physiology</subject><subject>Bone Density - physiology</subject><subject>Femur - diagnostic imaging</subject><subject>Radiographic Image Enhancement - methods</subject><subject>Reindeer</subject><issn>0967-3334</issn><issn>1361-6579</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNo9kD1PwzAQhi0EoqXwA1hQNqYQny9O4hGVT6lSF5gtO7m0QfnCTob-exK1dLkb7n2fkx7G7oE_Ac-yiKskDRExjhAjiIS6YEvABMJEpuqSLc_3Bbvx_odzgEzIa7YQAmQiMFuy7cto6pBacrtDUFS7ajB14ExRdTtn-v0hqNpg2FNgvCfvG2qHoCsD27UUNJTvTVvlU6F3XU9uqMjfsqvS1J7uTnvFvt9ev9Yf4Wb7_rl-3oQ5cj6EkqOKueGWsrQAMMCREErMJViTiQRTa3OIrZBoCQWRLVKU1kpT2tygwhV7PHKn178j-UE3lc-prk1L3ei1AlCxUhlOSTgmc9d576jUvasa4w4auJ416lmTnjVNQ4MWM_3hRB9tQ8W58e8N_wCCO24z</recordid><startdate>201201</startdate><enddate>201201</enddate><creator>Toljamo, P S</creator><creator>Lammentausta, E</creator><creator>Pulkkinen, P</creator><creator>Tervonen, O</creator><creator>Jämsä, T</creator><creator>Nieminen, M T</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201201</creationdate><title>Dual-energy digital radiography in the assessment of bone mechanical properties</title><author>Toljamo, P S ; Lammentausta, E ; Pulkkinen, P ; Tervonen, O ; Jämsä, T ; Nieminen, M T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c300t-503940a0be87d11a103e31f3c51ba82637bbc14b253be32eebd735bb5afbca393</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Absorptiometry, Photon - methods</topic><topic>Animals</topic><topic>Biomechanical Phenomena - physiology</topic><topic>Bone Density - physiology</topic><topic>Femur - diagnostic imaging</topic><topic>Radiographic Image Enhancement - methods</topic><topic>Reindeer</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Toljamo, P S</creatorcontrib><creatorcontrib>Lammentausta, E</creatorcontrib><creatorcontrib>Pulkkinen, P</creatorcontrib><creatorcontrib>Tervonen, O</creatorcontrib><creatorcontrib>Jämsä, T</creatorcontrib><creatorcontrib>Nieminen, M T</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physiological measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Toljamo, P S</au><au>Lammentausta, E</au><au>Pulkkinen, P</au><au>Tervonen, O</au><au>Jämsä, T</au><au>Nieminen, M T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dual-energy digital radiography in the assessment of bone mechanical properties</atitle><jtitle>Physiological measurement</jtitle><addtitle>Physiol Meas</addtitle><date>2012-01</date><risdate>2012</risdate><volume>33</volume><issue>1</issue><spage>29</spage><epage>37</epage><pages>29-37</pages><issn>0967-3334</issn><eissn>1361-6579</eissn><abstract>At present, bone fragility and fracture risk are estimated with bone mineral density (BMD), measured by dual-energy x-ray absorptiometry (DXA). It is known that DXA-based BMD (BMD(DXA)) has a relationship with mechanical characteristics of bone. Dual-energy digital radiography (DEDR) has also been shown to be a potential method to determine BMD, but the ability of DEDR-based BMD (BMD(DEDR)) to predict bone mechanical properties is not yet known. In this study, we investigated the ability of BMD(DEDR) to predict the mechanical characteristics of bone. Reindeer femora (N = 50) were imaged at two different energies (79 and 100 kV(p)) using a clinical digital radiography system. BMD was determined in four regions from these images using the DXA calculation principle. Femora were mechanically tested using axial loading configuration. Mechanical parameters were correlated with the BMD(DEDR) and BMD(DXA) of the femoral neck (FNBMD(DEDR) and FNBMD(DXA)). FNBMD(DEDR) and FNBMD(DXA) both correlated moderately with mechanical parameters. The highest correlations were found with maximal load (r = 0.53 and r = 0.65, p &lt; 0.01, respectively). No statistically significant differences were found between the correlation coefficients when comparing the FNBMD(DEDR) or FNBMD(DXA) values and mechanical parameters. The correlation coefficient between BMD(DEDR) and BMD(DXA) varied between r = 0.56 and 0.86 (p &lt; 0.01) in different regions of the upper femur. In conclusion, BMD(DEDR) predicts the mechanical parameters of reindeer bone with similar accuracy as BMD(DXA).</abstract><cop>England</cop><pmid>22156238</pmid><doi>10.1088/0967-3334/33/1/29</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0967-3334
ispartof Physiological measurement, 2012-01, Vol.33 (1), p.29-37
issn 0967-3334
1361-6579
language eng
recordid cdi_proquest_miscellaneous_911949983
source Institute of Physics
subjects Absorptiometry, Photon - methods
Animals
Biomechanical Phenomena - physiology
Bone Density - physiology
Femur - diagnostic imaging
Radiographic Image Enhancement - methods
Reindeer
title Dual-energy digital radiography in the assessment of bone mechanical properties
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T18%3A21%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dual-energy%20digital%20radiography%20in%20the%20assessment%20of%20bone%20mechanical%20properties&rft.jtitle=Physiological%20measurement&rft.au=Toljamo,%20P%20S&rft.date=2012-01&rft.volume=33&rft.issue=1&rft.spage=29&rft.epage=37&rft.pages=29-37&rft.issn=0967-3334&rft.eissn=1361-6579&rft_id=info:doi/10.1088/0967-3334/33/1/29&rft_dat=%3Cproquest_cross%3E911949983%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c300t-503940a0be87d11a103e31f3c51ba82637bbc14b253be32eebd735bb5afbca393%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=911949983&rft_id=info:pmid/22156238&rfr_iscdi=true