Loading…
Implementation of the beam reversal technique on compact cesium clocks: towards an improvement in accuracy
Reports the evaluation of the residual phase difference /spl utri//spl phi/ in a short (18 cm) Ramsey cavity by implementing the beam reversal technique in an optically pumped cesium beam clock. /spl utri//spl phi/ is measured to be 21 /spl plusmn/1.5 /spl mu/rad, allowing a more accurate evaluation...
Saved in:
Published in: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control ferroelectrics, and frequency control, 2001-11, Vol.48 (6), p.1513-1516 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Reports the evaluation of the residual phase difference /spl utri//spl phi/ in a short (18 cm) Ramsey cavity by implementing the beam reversal technique in an optically pumped cesium beam clock. /spl utri//spl phi/ is measured to be 21 /spl plusmn/1.5 /spl mu/rad, allowing a more accurate evaluation of the frequency performance of this small cesium clock. Finally, the clock accuracy is equal to 1.1/spl middot/10/sup -13/. |
---|---|
ISSN: | 0885-3010 1525-8955 |
DOI: | 10.1109/58.971701 |