In vivo polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in rodent cerebral cortex

Maintaining a reliable neural interface is a well-known challenge with implanted neural prostheses. Here we evaluate a method of forming an integrated neural interface through polymerization of PEDOT in vivo. Polymerization resulted in lower impedance and improved recording quality of local field po...

Full description

Saved in:
Bibliographic Details
Main Authors: Wilks, S. J., Woolley, A. J., Liangqi Ouyang, Martin, D. C., Otto, K. J.
Format: Conference Proceeding
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c398t-cdb8cdde2b1f56db44962728332b3d64f577157c20ae385b91b93b84534454f83
cites
container_end_page 5415
container_issue
container_start_page 5412
container_title
container_volume 2011
creator Wilks, S. J.
Woolley, A. J.
Liangqi Ouyang
Martin, D. C.
Otto, K. J.
description Maintaining a reliable neural interface is a well-known challenge with implanted neural prostheses. Here we evaluate a method of forming an integrated neural interface through polymerization of PEDOT in vivo. Polymerization resulted in lower impedance and improved recording quality of local field potentials on implanted electrodes in the rat cerebral cortex. Histological analysis by optical microscopy confirmed successful integration of the PEDOT within tissue surrounding implanted electrodes. This technique offers a unique neural interfacing approach with potential to improve the long-term functionality of neural prostheses.
doi_str_mv 10.1109/IEMBS.2011.6091338
format conference_proceeding
fullrecord <record><control><sourceid>proquest_6IE</sourceid><recordid>TN_cdi_proquest_miscellaneous_916854394</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6091338</ieee_id><sourcerecordid>916854394</sourcerecordid><originalsourceid>FETCH-LOGICAL-c398t-cdb8cdde2b1f56db44962728332b3d64f577157c20ae385b91b93b84534454f83</originalsourceid><addsrcrecordid>eNo1kFtLw0AQhdcbttb-AX3Jmy2Ymtlbdh-1Vi1UKljBB6HkMqEraTZu0tL46w1W52U45zsMhyHkAoIRQKBvppPnu9cRDQBGMtDAmDogZ8Ap5xwolYekC0Ion0sQR6SvQ_XPAI5bFmjuSxW-d0i_qj6DdqTUjNFT0qGUCiEkdMnHtPC2Zmu90ubNGp35jmpjC89mv86AXXMf61WTY4GpsbumXhlbrlo19AYvk_v5YuiZwnM2xaL2EnQYuyj3Eutq3J2TkyzKK-z_7R55e5gsxk_-bP44Hd_O_IRpVftJGqskTZHGkAmZxpxrSUOq2q4xSyXPRBiCCBMaRMiUiDXEmsWKC8a54JliPXK1v1s6-7XBql6uTZVgnkcF2k211CCV4EzzNnm5TxpEXJbOrCPXLP--y34Auipmyw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>916854394</pqid></control><display><type>conference_proceeding</type><title>In vivo polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in rodent cerebral cortex</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Wilks, S. J. ; Woolley, A. J. ; Liangqi Ouyang ; Martin, D. C. ; Otto, K. J.</creator><creatorcontrib>Wilks, S. J. ; Woolley, A. J. ; Liangqi Ouyang ; Martin, D. C. ; Otto, K. J.</creatorcontrib><description>Maintaining a reliable neural interface is a well-known challenge with implanted neural prostheses. Here we evaluate a method of forming an integrated neural interface through polymerization of PEDOT in vivo. Polymerization resulted in lower impedance and improved recording quality of local field potentials on implanted electrodes in the rat cerebral cortex. Histological analysis by optical microscopy confirmed successful integration of the PEDOT within tissue surrounding implanted electrodes. This technique offers a unique neural interfacing approach with potential to improve the long-term functionality of neural prostheses.</description><identifier>ISSN: 1094-687X</identifier><identifier>ISBN: 9781424441211</identifier><identifier>ISBN: 1424441218</identifier><identifier>EISSN: 1558-4615</identifier><identifier>EISSN: 2694-0604</identifier><identifier>EISBN: 1424441226</identifier><identifier>EISBN: 1457715899</identifier><identifier>EISBN: 9781457715891</identifier><identifier>EISBN: 9781424441228</identifier><identifier>DOI: 10.1109/IEMBS.2011.6091338</identifier><identifier>PMID: 22255561</identifier><language>eng</language><publisher>IEEE</publisher><subject>Educational institutions ; Electrodes ; Fluorescence ; Impedance ; In vivo ; Polymers ; Reliability</subject><ispartof>2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011, Vol.2011, p.5412-5415</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c398t-cdb8cdde2b1f56db44962728332b3d64f577157c20ae385b91b93b84534454f83</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6091338$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,2058,27924,27925,54920</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6091338$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Wilks, S. J.</creatorcontrib><creatorcontrib>Woolley, A. J.</creatorcontrib><creatorcontrib>Liangqi Ouyang</creatorcontrib><creatorcontrib>Martin, D. C.</creatorcontrib><creatorcontrib>Otto, K. J.</creatorcontrib><title>In vivo polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in rodent cerebral cortex</title><title>2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society</title><addtitle>IEMBS</addtitle><description>Maintaining a reliable neural interface is a well-known challenge with implanted neural prostheses. Here we evaluate a method of forming an integrated neural interface through polymerization of PEDOT in vivo. Polymerization resulted in lower impedance and improved recording quality of local field potentials on implanted electrodes in the rat cerebral cortex. Histological analysis by optical microscopy confirmed successful integration of the PEDOT within tissue surrounding implanted electrodes. This technique offers a unique neural interfacing approach with potential to improve the long-term functionality of neural prostheses.</description><subject>Educational institutions</subject><subject>Electrodes</subject><subject>Fluorescence</subject><subject>Impedance</subject><subject>In vivo</subject><subject>Polymers</subject><subject>Reliability</subject><issn>1094-687X</issn><issn>1558-4615</issn><issn>2694-0604</issn><isbn>9781424441211</isbn><isbn>1424441218</isbn><isbn>1424441226</isbn><isbn>1457715899</isbn><isbn>9781457715891</isbn><isbn>9781424441228</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2011</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo1kFtLw0AQhdcbttb-AX3Jmy2Ymtlbdh-1Vi1UKljBB6HkMqEraTZu0tL46w1W52U45zsMhyHkAoIRQKBvppPnu9cRDQBGMtDAmDogZ8Ap5xwolYekC0Ion0sQR6SvQ_XPAI5bFmjuSxW-d0i_qj6DdqTUjNFT0qGUCiEkdMnHtPC2Zmu90ubNGp35jmpjC89mv86AXXMf61WTY4GpsbumXhlbrlo19AYvk_v5YuiZwnM2xaL2EnQYuyj3Eutq3J2TkyzKK-z_7R55e5gsxk_-bP44Hd_O_IRpVftJGqskTZHGkAmZxpxrSUOq2q4xSyXPRBiCCBMaRMiUiDXEmsWKC8a54JliPXK1v1s6-7XBql6uTZVgnkcF2k211CCV4EzzNnm5TxpEXJbOrCPXLP--y34Auipmyw</recordid><startdate>20110101</startdate><enddate>20110101</enddate><creator>Wilks, S. J.</creator><creator>Woolley, A. J.</creator><creator>Liangqi Ouyang</creator><creator>Martin, D. C.</creator><creator>Otto, K. J.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope><scope>7X8</scope></search><sort><creationdate>20110101</creationdate><title>In vivo polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in rodent cerebral cortex</title><author>Wilks, S. J. ; Woolley, A. J. ; Liangqi Ouyang ; Martin, D. C. ; Otto, K. J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c398t-cdb8cdde2b1f56db44962728332b3d64f577157c20ae385b91b93b84534454f83</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Educational institutions</topic><topic>Electrodes</topic><topic>Fluorescence</topic><topic>Impedance</topic><topic>In vivo</topic><topic>Polymers</topic><topic>Reliability</topic><toplevel>online_resources</toplevel><creatorcontrib>Wilks, S. J.</creatorcontrib><creatorcontrib>Woolley, A. J.</creatorcontrib><creatorcontrib>Liangqi Ouyang</creatorcontrib><creatorcontrib>Martin, D. C.</creatorcontrib><creatorcontrib>Otto, K. J.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection><collection>MEDLINE - Academic</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Wilks, S. J.</au><au>Woolley, A. J.</au><au>Liangqi Ouyang</au><au>Martin, D. C.</au><au>Otto, K. J.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>In vivo polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in rodent cerebral cortex</atitle><btitle>2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society</btitle><stitle>IEMBS</stitle><date>2011-01-01</date><risdate>2011</risdate><volume>2011</volume><spage>5412</spage><epage>5415</epage><pages>5412-5415</pages><issn>1094-687X</issn><eissn>1558-4615</eissn><eissn>2694-0604</eissn><isbn>9781424441211</isbn><isbn>1424441218</isbn><eisbn>1424441226</eisbn><eisbn>1457715899</eisbn><eisbn>9781457715891</eisbn><eisbn>9781424441228</eisbn><abstract>Maintaining a reliable neural interface is a well-known challenge with implanted neural prostheses. Here we evaluate a method of forming an integrated neural interface through polymerization of PEDOT in vivo. Polymerization resulted in lower impedance and improved recording quality of local field potentials on implanted electrodes in the rat cerebral cortex. Histological analysis by optical microscopy confirmed successful integration of the PEDOT within tissue surrounding implanted electrodes. This technique offers a unique neural interfacing approach with potential to improve the long-term functionality of neural prostheses.</abstract><pub>IEEE</pub><pmid>22255561</pmid><doi>10.1109/IEMBS.2011.6091338</doi><tpages>4</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1094-687X
ispartof 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011, Vol.2011, p.5412-5415
issn 1094-687X
1558-4615
2694-0604
language eng
recordid cdi_proquest_miscellaneous_916854394
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Educational institutions
Electrodes
Fluorescence
Impedance
In vivo
Polymers
Reliability
title In vivo polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in rodent cerebral cortex
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T22%3A20%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=In%20vivo%20polymerization%20of%20poly(3,4-ethylenedioxythiophene)%20(PEDOT)%20in%20rodent%20cerebral%20cortex&rft.btitle=2011%20Annual%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%20Society&rft.au=Wilks,%20S.%20J.&rft.date=2011-01-01&rft.volume=2011&rft.spage=5412&rft.epage=5415&rft.pages=5412-5415&rft.issn=1094-687X&rft.eissn=1558-4615&rft.isbn=9781424441211&rft.isbn_list=1424441218&rft_id=info:doi/10.1109/IEMBS.2011.6091338&rft.eisbn=1424441226&rft.eisbn_list=1457715899&rft.eisbn_list=9781457715891&rft.eisbn_list=9781424441228&rft_dat=%3Cproquest_6IE%3E916854394%3C/proquest_6IE%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c398t-cdb8cdde2b1f56db44962728332b3d64f577157c20ae385b91b93b84534454f83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=916854394&rft_id=info:pmid/22255561&rft_ieee_id=6091338&rfr_iscdi=true