Loading…

Better stent expansion by two-time inflation of stent balloon and its responsible mechanism

Summary Objectives We determined the effect of two-time inflation of the stent balloon on stent expansion and its responsible factor. Methods Subjects included 61 patients with de novo coronary artery lesions, in whom 12 sirolimus-eluting, 27 paclitaxel-eluting, and 22 other stents were deployed twi...

Full description

Saved in:
Bibliographic Details
Published in:Journal of cardiology 2012-03, Vol.59 (2), p.160-166
Main Authors: Iwamoto, Yumiko, MD, Okamoto, Mitsunori, MD, FJCC, Hashimoto, Masaki, MD, Fukuda, Yukihiro, MD, Iwamoto, Akimichi, MD, Iwasaki, Toshitaka, MD, Kinoshita, Hiroki, MD, Kihara, Yasuki, MD, PhD, FJCC
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c573t-814ce35289d548e1804cad1f06c28f19f297f52b730dfbe9ba2588bed5a241d23
cites cdi_FETCH-LOGICAL-c573t-814ce35289d548e1804cad1f06c28f19f297f52b730dfbe9ba2588bed5a241d23
container_end_page 166
container_issue 2
container_start_page 160
container_title Journal of cardiology
container_volume 59
creator Iwamoto, Yumiko, MD
Okamoto, Mitsunori, MD, FJCC
Hashimoto, Masaki, MD
Fukuda, Yukihiro, MD
Iwamoto, Akimichi, MD
Iwasaki, Toshitaka, MD
Kinoshita, Hiroki, MD
Kihara, Yasuki, MD, PhD, FJCC
description Summary Objectives We determined the effect of two-time inflation of the stent balloon on stent expansion and its responsible factor. Methods Subjects included 61 patients with de novo coronary artery lesions, in whom 12 sirolimus-eluting, 27 paclitaxel-eluting, and 22 other stents were deployed twice at identical inflation pressures (11.3 ± 2.3 atm) and inflation times (5, 10, 20, and 40 s). After the first and second deployments, minimum lumen diameter (MLD), minimum lumen area (MLA), and distensibility index (DI) were determined using intravascular ultrasound. Results After the second inflation, MLA was significantly increased (5 s: 12.9%, 10 s: 14.5%, 20 s: 9.4%, 40 s: 9.5%). MLD and DI were also significantly increased. In the single and double inflation groups, DI in each group was significantly correlated with inflation time (single: r = 0.409, double: r = 0.351). DI was not significantly different between double 5-s and single 10-s inflations, between double 10-s and single 20-s inflations, or between double 20-s and single 40-s inflations. Additional stent balloon inflation by higher pressure in 30% and another balloon in 18% of the patients were required. Conclusions Two-time stent balloon inflation may allow better stent expansion regardless of inflation time and two-time inflation may be equivalent to longer inflation.
doi_str_mv 10.1016/j.jjcc.2011.12.003
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_924963286</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0914508711002644</els_id><sourcerecordid>924963286</sourcerecordid><originalsourceid>FETCH-LOGICAL-c573t-814ce35289d548e1804cad1f06c28f19f297f52b730dfbe9ba2588bed5a241d23</originalsourceid><addsrcrecordid>eNp9kU2LFDEQhoMo7rj6BzxI3zx1m6TT6TSIoMv6AQsedj15COmkgmnTyZhkXOffm2ZGDx48FRTP-0I9hdBzgjuCCX-1dMuidUcxIR2hHcb9A7QjYuQtG3vxEO3wRFg7YDFeoCc5LxhzPAn-GF1QSjlnHO_Q13dQCqQmFwilgV97FbKLoZmPTbmPbXErNC5Yr8q2jfYMzsr7WBcqmMaV3CTI-1iTs4dmBf1NBZfXp-iRVT7Ds_O8RF_eX99dfWxvPn_4dPX2ptXD2JdWEKahH6iYzMAEEIGZVoZYzDUVlkyWTqMd6Dz22NgZplnRQYgZzKAoI4b2l-jlqXef4o8D5CJXlzV4rwLEQ5YTZRPvqeCVpCdSp5hzAiv3ya0qHSXBcnMqF7k5lZtTSaisTmvoxbn-MK9g_kb-SKzA6xMA9cifDpLM2kHQYFwCXaSJ7v_9b_6Ja--C08p_hyPkJR5SqPokkbkG5O321e2phGBMOWP9b_LwnY0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>924963286</pqid></control><display><type>article</type><title>Better stent expansion by two-time inflation of stent balloon and its responsible mechanism</title><source>ScienceDirect Freedom Collection</source><creator>Iwamoto, Yumiko, MD ; Okamoto, Mitsunori, MD, FJCC ; Hashimoto, Masaki, MD ; Fukuda, Yukihiro, MD ; Iwamoto, Akimichi, MD ; Iwasaki, Toshitaka, MD ; Kinoshita, Hiroki, MD ; Kihara, Yasuki, MD, PhD, FJCC</creator><creatorcontrib>Iwamoto, Yumiko, MD ; Okamoto, Mitsunori, MD, FJCC ; Hashimoto, Masaki, MD ; Fukuda, Yukihiro, MD ; Iwamoto, Akimichi, MD ; Iwasaki, Toshitaka, MD ; Kinoshita, Hiroki, MD ; Kihara, Yasuki, MD, PhD, FJCC</creatorcontrib><description>Summary Objectives We determined the effect of two-time inflation of the stent balloon on stent expansion and its responsible factor. Methods Subjects included 61 patients with de novo coronary artery lesions, in whom 12 sirolimus-eluting, 27 paclitaxel-eluting, and 22 other stents were deployed twice at identical inflation pressures (11.3 ± 2.3 atm) and inflation times (5, 10, 20, and 40 s). After the first and second deployments, minimum lumen diameter (MLD), minimum lumen area (MLA), and distensibility index (DI) were determined using intravascular ultrasound. Results After the second inflation, MLA was significantly increased (5 s: 12.9%, 10 s: 14.5%, 20 s: 9.4%, 40 s: 9.5%). MLD and DI were also significantly increased. In the single and double inflation groups, DI in each group was significantly correlated with inflation time (single: r = 0.409, double: r = 0.351). DI was not significantly different between double 5-s and single 10-s inflations, between double 10-s and single 20-s inflations, or between double 20-s and single 40-s inflations. Additional stent balloon inflation by higher pressure in 30% and another balloon in 18% of the patients were required. Conclusions Two-time stent balloon inflation may allow better stent expansion regardless of inflation time and two-time inflation may be equivalent to longer inflation.</description><identifier>ISSN: 0914-5087</identifier><identifier>EISSN: 1876-4738</identifier><identifier>DOI: 10.1016/j.jjcc.2011.12.003</identifier><identifier>PMID: 22266460</identifier><language>eng</language><publisher>Netherlands: Elsevier Ltd</publisher><subject>Aged ; Angioplasty, Balloon, Coronary ; Cardiovascular ; Catheterization ; Coronary artery disease ; Coronary Stenosis - therapy ; Drug-Eluting Stents ; Endosonography ; Equipment Design ; Female ; Humans ; Insufflation - instrumentation ; Interventional cardiology ; Male ; Paclitaxel - administration &amp; dosage ; Sirolimus - administration &amp; dosage ; Stent ; Stents</subject><ispartof>Journal of cardiology, 2012-03, Vol.59 (2), p.160-166</ispartof><rights>2012</rights><rights>Copyright © 2012. Published by Elsevier Ltd.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c573t-814ce35289d548e1804cad1f06c28f19f297f52b730dfbe9ba2588bed5a241d23</citedby><cites>FETCH-LOGICAL-c573t-814ce35289d548e1804cad1f06c28f19f297f52b730dfbe9ba2588bed5a241d23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22266460$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Iwamoto, Yumiko, MD</creatorcontrib><creatorcontrib>Okamoto, Mitsunori, MD, FJCC</creatorcontrib><creatorcontrib>Hashimoto, Masaki, MD</creatorcontrib><creatorcontrib>Fukuda, Yukihiro, MD</creatorcontrib><creatorcontrib>Iwamoto, Akimichi, MD</creatorcontrib><creatorcontrib>Iwasaki, Toshitaka, MD</creatorcontrib><creatorcontrib>Kinoshita, Hiroki, MD</creatorcontrib><creatorcontrib>Kihara, Yasuki, MD, PhD, FJCC</creatorcontrib><title>Better stent expansion by two-time inflation of stent balloon and its responsible mechanism</title><title>Journal of cardiology</title><addtitle>J Cardiol</addtitle><description>Summary Objectives We determined the effect of two-time inflation of the stent balloon on stent expansion and its responsible factor. Methods Subjects included 61 patients with de novo coronary artery lesions, in whom 12 sirolimus-eluting, 27 paclitaxel-eluting, and 22 other stents were deployed twice at identical inflation pressures (11.3 ± 2.3 atm) and inflation times (5, 10, 20, and 40 s). After the first and second deployments, minimum lumen diameter (MLD), minimum lumen area (MLA), and distensibility index (DI) were determined using intravascular ultrasound. Results After the second inflation, MLA was significantly increased (5 s: 12.9%, 10 s: 14.5%, 20 s: 9.4%, 40 s: 9.5%). MLD and DI were also significantly increased. In the single and double inflation groups, DI in each group was significantly correlated with inflation time (single: r = 0.409, double: r = 0.351). DI was not significantly different between double 5-s and single 10-s inflations, between double 10-s and single 20-s inflations, or between double 20-s and single 40-s inflations. Additional stent balloon inflation by higher pressure in 30% and another balloon in 18% of the patients were required. Conclusions Two-time stent balloon inflation may allow better stent expansion regardless of inflation time and two-time inflation may be equivalent to longer inflation.</description><subject>Aged</subject><subject>Angioplasty, Balloon, Coronary</subject><subject>Cardiovascular</subject><subject>Catheterization</subject><subject>Coronary artery disease</subject><subject>Coronary Stenosis - therapy</subject><subject>Drug-Eluting Stents</subject><subject>Endosonography</subject><subject>Equipment Design</subject><subject>Female</subject><subject>Humans</subject><subject>Insufflation - instrumentation</subject><subject>Interventional cardiology</subject><subject>Male</subject><subject>Paclitaxel - administration &amp; dosage</subject><subject>Sirolimus - administration &amp; dosage</subject><subject>Stent</subject><subject>Stents</subject><issn>0914-5087</issn><issn>1876-4738</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNp9kU2LFDEQhoMo7rj6BzxI3zx1m6TT6TSIoMv6AQsedj15COmkgmnTyZhkXOffm2ZGDx48FRTP-0I9hdBzgjuCCX-1dMuidUcxIR2hHcb9A7QjYuQtG3vxEO3wRFg7YDFeoCc5LxhzPAn-GF1QSjlnHO_Q13dQCqQmFwilgV97FbKLoZmPTbmPbXErNC5Yr8q2jfYMzsr7WBcqmMaV3CTI-1iTs4dmBf1NBZfXp-iRVT7Ds_O8RF_eX99dfWxvPn_4dPX2ptXD2JdWEKahH6iYzMAEEIGZVoZYzDUVlkyWTqMd6Dz22NgZplnRQYgZzKAoI4b2l-jlqXef4o8D5CJXlzV4rwLEQ5YTZRPvqeCVpCdSp5hzAiv3ya0qHSXBcnMqF7k5lZtTSaisTmvoxbn-MK9g_kb-SKzA6xMA9cifDpLM2kHQYFwCXaSJ7v_9b_6Ja--C08p_hyPkJR5SqPokkbkG5O321e2phGBMOWP9b_LwnY0</recordid><startdate>20120301</startdate><enddate>20120301</enddate><creator>Iwamoto, Yumiko, MD</creator><creator>Okamoto, Mitsunori, MD, FJCC</creator><creator>Hashimoto, Masaki, MD</creator><creator>Fukuda, Yukihiro, MD</creator><creator>Iwamoto, Akimichi, MD</creator><creator>Iwasaki, Toshitaka, MD</creator><creator>Kinoshita, Hiroki, MD</creator><creator>Kihara, Yasuki, MD, PhD, FJCC</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20120301</creationdate><title>Better stent expansion by two-time inflation of stent balloon and its responsible mechanism</title><author>Iwamoto, Yumiko, MD ; Okamoto, Mitsunori, MD, FJCC ; Hashimoto, Masaki, MD ; Fukuda, Yukihiro, MD ; Iwamoto, Akimichi, MD ; Iwasaki, Toshitaka, MD ; Kinoshita, Hiroki, MD ; Kihara, Yasuki, MD, PhD, FJCC</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c573t-814ce35289d548e1804cad1f06c28f19f297f52b730dfbe9ba2588bed5a241d23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Aged</topic><topic>Angioplasty, Balloon, Coronary</topic><topic>Cardiovascular</topic><topic>Catheterization</topic><topic>Coronary artery disease</topic><topic>Coronary Stenosis - therapy</topic><topic>Drug-Eluting Stents</topic><topic>Endosonography</topic><topic>Equipment Design</topic><topic>Female</topic><topic>Humans</topic><topic>Insufflation - instrumentation</topic><topic>Interventional cardiology</topic><topic>Male</topic><topic>Paclitaxel - administration &amp; dosage</topic><topic>Sirolimus - administration &amp; dosage</topic><topic>Stent</topic><topic>Stents</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Iwamoto, Yumiko, MD</creatorcontrib><creatorcontrib>Okamoto, Mitsunori, MD, FJCC</creatorcontrib><creatorcontrib>Hashimoto, Masaki, MD</creatorcontrib><creatorcontrib>Fukuda, Yukihiro, MD</creatorcontrib><creatorcontrib>Iwamoto, Akimichi, MD</creatorcontrib><creatorcontrib>Iwasaki, Toshitaka, MD</creatorcontrib><creatorcontrib>Kinoshita, Hiroki, MD</creatorcontrib><creatorcontrib>Kihara, Yasuki, MD, PhD, FJCC</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Iwamoto, Yumiko, MD</au><au>Okamoto, Mitsunori, MD, FJCC</au><au>Hashimoto, Masaki, MD</au><au>Fukuda, Yukihiro, MD</au><au>Iwamoto, Akimichi, MD</au><au>Iwasaki, Toshitaka, MD</au><au>Kinoshita, Hiroki, MD</au><au>Kihara, Yasuki, MD, PhD, FJCC</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Better stent expansion by two-time inflation of stent balloon and its responsible mechanism</atitle><jtitle>Journal of cardiology</jtitle><addtitle>J Cardiol</addtitle><date>2012-03-01</date><risdate>2012</risdate><volume>59</volume><issue>2</issue><spage>160</spage><epage>166</epage><pages>160-166</pages><issn>0914-5087</issn><eissn>1876-4738</eissn><abstract>Summary Objectives We determined the effect of two-time inflation of the stent balloon on stent expansion and its responsible factor. Methods Subjects included 61 patients with de novo coronary artery lesions, in whom 12 sirolimus-eluting, 27 paclitaxel-eluting, and 22 other stents were deployed twice at identical inflation pressures (11.3 ± 2.3 atm) and inflation times (5, 10, 20, and 40 s). After the first and second deployments, minimum lumen diameter (MLD), minimum lumen area (MLA), and distensibility index (DI) were determined using intravascular ultrasound. Results After the second inflation, MLA was significantly increased (5 s: 12.9%, 10 s: 14.5%, 20 s: 9.4%, 40 s: 9.5%). MLD and DI were also significantly increased. In the single and double inflation groups, DI in each group was significantly correlated with inflation time (single: r = 0.409, double: r = 0.351). DI was not significantly different between double 5-s and single 10-s inflations, between double 10-s and single 20-s inflations, or between double 20-s and single 40-s inflations. Additional stent balloon inflation by higher pressure in 30% and another balloon in 18% of the patients were required. Conclusions Two-time stent balloon inflation may allow better stent expansion regardless of inflation time and two-time inflation may be equivalent to longer inflation.</abstract><cop>Netherlands</cop><pub>Elsevier Ltd</pub><pmid>22266460</pmid><doi>10.1016/j.jjcc.2011.12.003</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0914-5087
ispartof Journal of cardiology, 2012-03, Vol.59 (2), p.160-166
issn 0914-5087
1876-4738
language eng
recordid cdi_proquest_miscellaneous_924963286
source ScienceDirect Freedom Collection
subjects Aged
Angioplasty, Balloon, Coronary
Cardiovascular
Catheterization
Coronary artery disease
Coronary Stenosis - therapy
Drug-Eluting Stents
Endosonography
Equipment Design
Female
Humans
Insufflation - instrumentation
Interventional cardiology
Male
Paclitaxel - administration & dosage
Sirolimus - administration & dosage
Stent
Stents
title Better stent expansion by two-time inflation of stent balloon and its responsible mechanism
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T15%3A43%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Better%20stent%20expansion%20by%20two-time%20inflation%20of%20stent%20balloon%20and%20its%20responsible%20mechanism&rft.jtitle=Journal%20of%20cardiology&rft.au=Iwamoto,%20Yumiko,%20MD&rft.date=2012-03-01&rft.volume=59&rft.issue=2&rft.spage=160&rft.epage=166&rft.pages=160-166&rft.issn=0914-5087&rft.eissn=1876-4738&rft_id=info:doi/10.1016/j.jjcc.2011.12.003&rft_dat=%3Cproquest_cross%3E924963286%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c573t-814ce35289d548e1804cad1f06c28f19f297f52b730dfbe9ba2588bed5a241d23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=924963286&rft_id=info:pmid/22266460&rfr_iscdi=true