HPLC-UV method development for fentanyl determination in rat plasma and its application to elucidate pharmacokinetic behavior after i.p. administration to rats
A simple, rapid and validated high performance liquid chromatography method with UV detection for the quantification of an opioid agonist, fentanyl (FEN), in rat plasma was developed. The assay procedure involved chromatographic separation using a ZIC-HILIC SeQUANT column (250 mm × 4.6 mm, i.d., 5 μ...
Saved in:
Published in: | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2011-10, Vol.879 (27), p.2941-2944 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A simple, rapid and validated high performance liquid chromatography method with UV detection for the quantification of an opioid agonist, fentanyl (FEN), in rat plasma was developed. The assay procedure involved chromatographic separation using a ZIC-HILIC SeQUANT column (250
mm
×
4.6
mm, i.d., 5
μm) and a mobile phase of acetonitrile and acetate buffer (pH 3.4, 20
mM) of ratio (=65:35, v/v) at a flow rate of 1.2
mL/min and detection wavelength of 201
nm. Plasma sample (100
μL) pretreatment was based on simple deprotienization by acetonitrile spiked with clonidine as an internal standard (I.S.) of 20
ng/mL followed by extraction with
tert-butyl methyl ether and centrifugation. The organic layer was evaporated under N
2 gas and reconstituted with 100
μL of acetate buffer (pH 3.4, 20
mM), and 50-μL portions of reconstituted sample were injected onto the column. Sample analysis including sample pretreatment was achieved within 35
min. Calibration curve was linear (
r
≥
0.998) from 5 to 100
ng/mL. Both intra- and inter-day assay precisions that are presented through RSD were lower than 12.6% for intra-day and lower than 12.0% for inter-day assessment. Limit of detection was 0.8
ng/mL at S/N of 3. This method was omitting the use of expensive solid phase extraction and time consuming liquid extraction procedures. Moreover, the present method was successfully applied to study pharmacokinetic parameters of FEN after intraperitoneal administration to male Wistar rat. Pharmacokinetic parameters estimated by using moment analysis were
T
1/2 198.3
±
44.7
min,
T
max 28.3
±
2.9
min and AUC
0–180 15.6
±
2.9
(×10
2)
ng
min/mL. |
---|---|