Loading…

Highly Sensitive Molecularly Imprinted Electrochemical Sensor Based on the Double Amplification by an Inorganic Prussian Blue Catalytic Polymer and the Enzymatic Effect of Glucose Oxidase

A novel strategy to improve the sensitivity of molecularly imprinted polymer (MIP) sensors was proposed. An electrocatalytic Prussian blue (PB) film was electrochemically polymerized on an electrode surface to fabricate an MIP electrochemical sensor using oxytetracycline (OTC) as a template. The OTC...

Full description

Saved in:
Bibliographic Details
Published in:Analytical chemistry (Washington) 2012-02, Vol.84 (4), p.1888-1893
Main Authors: Li, Jianping, Li, Yuping, Zhang, Yun, Wei, Ge
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a371t-721abb917735f63aa2c344c61f6ed4053387d97af3026502994840c68c99da363
cites cdi_FETCH-LOGICAL-a371t-721abb917735f63aa2c344c61f6ed4053387d97af3026502994840c68c99da363
container_end_page 1893
container_issue 4
container_start_page 1888
container_title Analytical chemistry (Washington)
container_volume 84
creator Li, Jianping
Li, Yuping
Zhang, Yun
Wei, Ge
description A novel strategy to improve the sensitivity of molecularly imprinted polymer (MIP) sensors was proposed. An electrocatalytic Prussian blue (PB) film was electrochemically polymerized on an electrode surface to fabricate an MIP electrochemical sensor using oxytetracycline (OTC) as a template. The OTC determination relied on a competition reaction between OTC and glucose-oxidase-labeled OTC and the catalytic reduction of hydrogen peroxide by the modified PB film. Experimental results show that double amplification, which is based on the catalysis of inorganic PB films and the enzymatic effect of glucose oxidase, can remarkably increase the assay sensitivity. The main experimental conditions (including electrocatalysis of the PB film, pH effects, incubation and competition times, and anti-interference) were optimized. This novel MIP sensor can offer an femtomole detection limit for OTC. In addition, the feasibility of its practical applications has been demonstrated in the analysis of a series of real milk samples.
doi_str_mv 10.1021/ac2026817
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_927990680</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>927990680</sourcerecordid><originalsourceid>FETCH-LOGICAL-a371t-721abb917735f63aa2c344c61f6ed4053387d97af3026502994840c68c99da363</originalsourceid><addsrcrecordid>eNplkV9rFDEUxYModlt98AtIEKT4MJo_M5nJY7uu7UKlgvo83M0k3ZRMsk1mxPGr-eXMtGsX9OnCuT_OvZyD0CtK3lPC6AdQjDDR0PoJWtCKkUI0DXuKFoQQXrCakCN0nNItIZQSKp6jI8ZYyQRvFuj3pb3Zugl_1T7Zwf7Q-HNwWo0OYlbX_S5aP-gOr7I4xKC2urcK3D0fIj6HlJfB42Gr8ccwbpzGZ_3OWZOpwebFZsLg8dqHeAPeKvwljinZLJ27UeMlDOCmYdaDm3odM9zdm638r6mHebMyJt_GweALN6qQNL7-abt8-AV6ZsAl_XI_T9D3T6tvy8vi6vpivTy7KoDXdChqRmGzkbSueWUEB2CKl6US1AjdlaTivKk7WYPhOcSKMCnLpiRKNErKDrjgJ-j0wXcXw92o09D2NintHHgdxtRKVktJREMy-eYf8jaM0efnZqjmOfTZ7t0DpGJIKWrT5pB7iFNLSTv32T72mdnXe8Nx0-vukfxbYAbe7gFIuRcTwSubDlxVyaqR8sCBSoen_j_4B68utHM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>927734266</pqid></control><display><type>article</type><title>Highly Sensitive Molecularly Imprinted Electrochemical Sensor Based on the Double Amplification by an Inorganic Prussian Blue Catalytic Polymer and the Enzymatic Effect of Glucose Oxidase</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Li, Jianping ; Li, Yuping ; Zhang, Yun ; Wei, Ge</creator><creatorcontrib>Li, Jianping ; Li, Yuping ; Zhang, Yun ; Wei, Ge</creatorcontrib><description>A novel strategy to improve the sensitivity of molecularly imprinted polymer (MIP) sensors was proposed. An electrocatalytic Prussian blue (PB) film was electrochemically polymerized on an electrode surface to fabricate an MIP electrochemical sensor using oxytetracycline (OTC) as a template. The OTC determination relied on a competition reaction between OTC and glucose-oxidase-labeled OTC and the catalytic reduction of hydrogen peroxide by the modified PB film. Experimental results show that double amplification, which is based on the catalysis of inorganic PB films and the enzymatic effect of glucose oxidase, can remarkably increase the assay sensitivity. The main experimental conditions (including electrocatalysis of the PB film, pH effects, incubation and competition times, and anti-interference) were optimized. This novel MIP sensor can offer an femtomole detection limit for OTC. In addition, the feasibility of its practical applications has been demonstrated in the analysis of a series of real milk samples.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac2026817</identifier><identifier>PMID: 22242638</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Biosensing Techniques ; Catalysis ; Chemistry ; Electrochemistry ; Electrodes ; Exact sciences and technology ; Ferrocyanides - chemistry ; General, instrumentation ; Glucose Oxidase - metabolism ; Hydrogen peroxide ; Hydrogen Peroxide - metabolism ; Molecular Imprinting ; Oxytetracycline - chemistry ; Polymers ; Polymers - chemistry ; Sensors</subject><ispartof>Analytical chemistry (Washington), 2012-02, Vol.84 (4), p.1888-1893</ispartof><rights>Copyright © 2012 American Chemical Society</rights><rights>2015 INIST-CNRS</rights><rights>Copyright American Chemical Society Feb 21, 2012</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a371t-721abb917735f63aa2c344c61f6ed4053387d97af3026502994840c68c99da363</citedby><cites>FETCH-LOGICAL-a371t-721abb917735f63aa2c344c61f6ed4053387d97af3026502994840c68c99da363</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=25595899$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22242638$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Li, Jianping</creatorcontrib><creatorcontrib>Li, Yuping</creatorcontrib><creatorcontrib>Zhang, Yun</creatorcontrib><creatorcontrib>Wei, Ge</creatorcontrib><title>Highly Sensitive Molecularly Imprinted Electrochemical Sensor Based on the Double Amplification by an Inorganic Prussian Blue Catalytic Polymer and the Enzymatic Effect of Glucose Oxidase</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>A novel strategy to improve the sensitivity of molecularly imprinted polymer (MIP) sensors was proposed. An electrocatalytic Prussian blue (PB) film was electrochemically polymerized on an electrode surface to fabricate an MIP electrochemical sensor using oxytetracycline (OTC) as a template. The OTC determination relied on a competition reaction between OTC and glucose-oxidase-labeled OTC and the catalytic reduction of hydrogen peroxide by the modified PB film. Experimental results show that double amplification, which is based on the catalysis of inorganic PB films and the enzymatic effect of glucose oxidase, can remarkably increase the assay sensitivity. The main experimental conditions (including electrocatalysis of the PB film, pH effects, incubation and competition times, and anti-interference) were optimized. This novel MIP sensor can offer an femtomole detection limit for OTC. In addition, the feasibility of its practical applications has been demonstrated in the analysis of a series of real milk samples.</description><subject>Analytical chemistry</subject><subject>Biosensing Techniques</subject><subject>Catalysis</subject><subject>Chemistry</subject><subject>Electrochemistry</subject><subject>Electrodes</subject><subject>Exact sciences and technology</subject><subject>Ferrocyanides - chemistry</subject><subject>General, instrumentation</subject><subject>Glucose Oxidase - metabolism</subject><subject>Hydrogen peroxide</subject><subject>Hydrogen Peroxide - metabolism</subject><subject>Molecular Imprinting</subject><subject>Oxytetracycline - chemistry</subject><subject>Polymers</subject><subject>Polymers - chemistry</subject><subject>Sensors</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNplkV9rFDEUxYModlt98AtIEKT4MJo_M5nJY7uu7UKlgvo83M0k3ZRMsk1mxPGr-eXMtGsX9OnCuT_OvZyD0CtK3lPC6AdQjDDR0PoJWtCKkUI0DXuKFoQQXrCakCN0nNItIZQSKp6jI8ZYyQRvFuj3pb3Zugl_1T7Zwf7Q-HNwWo0OYlbX_S5aP-gOr7I4xKC2urcK3D0fIj6HlJfB42Gr8ccwbpzGZ_3OWZOpwebFZsLg8dqHeAPeKvwljinZLJ27UeMlDOCmYdaDm3odM9zdm638r6mHebMyJt_GweALN6qQNL7-abt8-AV6ZsAl_XI_T9D3T6tvy8vi6vpivTy7KoDXdChqRmGzkbSueWUEB2CKl6US1AjdlaTivKk7WYPhOcSKMCnLpiRKNErKDrjgJ-j0wXcXw92o09D2NintHHgdxtRKVktJREMy-eYf8jaM0efnZqjmOfTZ7t0DpGJIKWrT5pB7iFNLSTv32T72mdnXe8Nx0-vukfxbYAbe7gFIuRcTwSubDlxVyaqR8sCBSoen_j_4B68utHM</recordid><startdate>20120221</startdate><enddate>20120221</enddate><creator>Li, Jianping</creator><creator>Li, Yuping</creator><creator>Zhang, Yun</creator><creator>Wei, Ge</creator><general>American Chemical Society</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20120221</creationdate><title>Highly Sensitive Molecularly Imprinted Electrochemical Sensor Based on the Double Amplification by an Inorganic Prussian Blue Catalytic Polymer and the Enzymatic Effect of Glucose Oxidase</title><author>Li, Jianping ; Li, Yuping ; Zhang, Yun ; Wei, Ge</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a371t-721abb917735f63aa2c344c61f6ed4053387d97af3026502994840c68c99da363</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Analytical chemistry</topic><topic>Biosensing Techniques</topic><topic>Catalysis</topic><topic>Chemistry</topic><topic>Electrochemistry</topic><topic>Electrodes</topic><topic>Exact sciences and technology</topic><topic>Ferrocyanides - chemistry</topic><topic>General, instrumentation</topic><topic>Glucose Oxidase - metabolism</topic><topic>Hydrogen peroxide</topic><topic>Hydrogen Peroxide - metabolism</topic><topic>Molecular Imprinting</topic><topic>Oxytetracycline - chemistry</topic><topic>Polymers</topic><topic>Polymers - chemistry</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, Jianping</creatorcontrib><creatorcontrib>Li, Yuping</creatorcontrib><creatorcontrib>Zhang, Yun</creatorcontrib><creatorcontrib>Wei, Ge</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Jianping</au><au>Li, Yuping</au><au>Zhang, Yun</au><au>Wei, Ge</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Highly Sensitive Molecularly Imprinted Electrochemical Sensor Based on the Double Amplification by an Inorganic Prussian Blue Catalytic Polymer and the Enzymatic Effect of Glucose Oxidase</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2012-02-21</date><risdate>2012</risdate><volume>84</volume><issue>4</issue><spage>1888</spage><epage>1893</epage><pages>1888-1893</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>A novel strategy to improve the sensitivity of molecularly imprinted polymer (MIP) sensors was proposed. An electrocatalytic Prussian blue (PB) film was electrochemically polymerized on an electrode surface to fabricate an MIP electrochemical sensor using oxytetracycline (OTC) as a template. The OTC determination relied on a competition reaction between OTC and glucose-oxidase-labeled OTC and the catalytic reduction of hydrogen peroxide by the modified PB film. Experimental results show that double amplification, which is based on the catalysis of inorganic PB films and the enzymatic effect of glucose oxidase, can remarkably increase the assay sensitivity. The main experimental conditions (including electrocatalysis of the PB film, pH effects, incubation and competition times, and anti-interference) were optimized. This novel MIP sensor can offer an femtomole detection limit for OTC. In addition, the feasibility of its practical applications has been demonstrated in the analysis of a series of real milk samples.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>22242638</pmid><doi>10.1021/ac2026817</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 2012-02, Vol.84 (4), p.1888-1893
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_miscellaneous_927990680
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
subjects Analytical chemistry
Biosensing Techniques
Catalysis
Chemistry
Electrochemistry
Electrodes
Exact sciences and technology
Ferrocyanides - chemistry
General, instrumentation
Glucose Oxidase - metabolism
Hydrogen peroxide
Hydrogen Peroxide - metabolism
Molecular Imprinting
Oxytetracycline - chemistry
Polymers
Polymers - chemistry
Sensors
title Highly Sensitive Molecularly Imprinted Electrochemical Sensor Based on the Double Amplification by an Inorganic Prussian Blue Catalytic Polymer and the Enzymatic Effect of Glucose Oxidase
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T10%3A43%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Highly%20Sensitive%20Molecularly%20Imprinted%20Electrochemical%20Sensor%20Based%20on%20the%20Double%20Amplification%20by%20an%20Inorganic%20Prussian%20Blue%20Catalytic%20Polymer%20and%20the%20Enzymatic%20Effect%20of%20Glucose%20Oxidase&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Li,%20Jianping&rft.date=2012-02-21&rft.volume=84&rft.issue=4&rft.spage=1888&rft.epage=1893&rft.pages=1888-1893&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac2026817&rft_dat=%3Cproquest_cross%3E927990680%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a371t-721abb917735f63aa2c344c61f6ed4053387d97af3026502994840c68c99da363%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=927734266&rft_id=info:pmid/22242638&rfr_iscdi=true