Loading…

Titanium-nitride-oxIde-coated stents multicenter registry in diaBEtic patienTs: the TIBET registry

We sought to explore the immediate clinical and angiographic results of the Titan ® stent implantation in diabetic patients, as well as the major adverse cardiac events (MACE) at 6-month follow-up. We enrolled 156 consecutive diabetic patients admitted to undergo percutaneous intervention for at lea...

Full description

Saved in:
Bibliographic Details
Published in:Heart and vessels 2012-03, Vol.27 (2), p.151-158
Main Authors: Chavarri, Mariano Valdés, Bethencourt, Armando, Pinar, Eduardo, Gomez, Alfredo, Portales, Javier Fernández, Pomar, Francisco, Calvo, Isabel, Minguez, Jose Ramón López, Valdesuso, Raúl, Moreu, José, Martínez, Antonio, Nammas, Wail
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We sought to explore the immediate clinical and angiographic results of the Titan ® stent implantation in diabetic patients, as well as the major adverse cardiac events (MACE) at 6-month follow-up. We enrolled 156 consecutive diabetic patients admitted to undergo percutaneous intervention for at least one significant (50%) coronary lesion. All lesions were treated with the Titan ® stent implantation according to the contemporary interventional techniques. Patients were prospectively followed-up for at least 6 months. The primary endpoint was MACE at 6-month follow-up [cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR)]. Secondary endpoints included angiographic and clinical procedural success, in-hospital MACE, TLR at 6-month follow-up, and stent thrombosis. The mean age was 66.7 ± 9.6 years, (68.4% males). A total of 197 Titan ® stents were implanted in 163 lesions. Direct stenting was performed in 45.2% of the cases. The mean stent diameter was 3.1 ± 0.61 mm, and the mean length was 18.0 ± 8.9 mm. Average stent deployment pressure was 13.9 ± 4.2 bars. Angiographic procedural success was achieved in 154 (98.7%) cases, and clinical procedural success was achieved in 153 (98.1%) cases. One patient developed in-hospital non-Q-wave MI following the procedure. Clinical follow-up was completed in 155 (99.4%) patients. Three patients (1.9%) died of a cardiac or unknown cause, and two (1.3%) developed MI. TLR was performed in 11 patients (7.1%). Cumulative MACE at 6-month follow-up occurred in 16 (10.3%) patients. No patient suffered stent thrombosis. Titan ® stent implantation in diabetic patients achieves an excellent immediate clinical and angiographic outcome, with a low incidence of MACE at mid-term follow-up.
ISSN:0910-8327
1615-2573