Use of active personal dosemeters in interventional radiology and cardiology: Tests in laboratory conditions and recommendations - ORAMED project

Active personal dosemeters (APD) have been found to be very efficient tools to reduce occupational doses in many applications of ionizing radiation. In order to be used in interventional radiology and cardiology (IR/IC), APDs should be able to measure low energy photons and pulsed radiation with rel...

Full description

Saved in:
Bibliographic Details
Published in:Radiation measurements 2011-11, Vol.46 (11), p.1252-1257
Main Authors: Clairand, I., Bordy, J.-M., Carinou, E., Daures, J., Debroas, J., Denozière, M., Donadille, L., Ginjaume, M., Itié, C., Koukorava, C., Krim, S., Lebacq, A.-L., Martin, P., Struelens, L., Sans-Merce, M., Vanhavere, F.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Active personal dosemeters (APD) have been found to be very efficient tools to reduce occupational doses in many applications of ionizing radiation. In order to be used in interventional radiology and cardiology (IR/IC), APDs should be able to measure low energy photons and pulsed radiation with relatively high instantaneous personal dose equivalent rates. A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008–2011) supported by the European Commission within its 7th Framework Program. In particular, eight commercial APDs were tested in continuous and pulsed X-ray fields delivered by calibration laboratories in order to evaluate their performances. Most of APDs provide a response in pulsed mode more or less affected by the personal dose equivalent rate, which means they could be used in routine monitoring provided that correction factors are introduced. These results emphasize the importance of adding tests in pulsed mode in type-test procedures for APDs. Some general recommendations are proposed in the end of this paper for the selection and use of APDs at IR/IC workplaces. ► Eight APDs were tested in continuous and pulsed X-ray fields in laboratory conditions. ► Most of APDs provide a correct response in continuous mode. ► Most of APDs provide a response in pulsed mode that can be affected by the personal dose equivalent rate. ► General recommendations are given to help in the selection and use of APDs at IR/IC workplaces.