Loading…
Real-time nozzle flow uniformity when using automatic section control on agricultural sprayers
Automatic section control (ASC) has been readily adopted by US producers on sprayers because it can improve operator productivity and decrease overlap or input usage leading to economic savings while reducing environmental impacts. However, there is limited knowledge about nozzle flow dynamics when...
Saved in:
Published in: | Computers and electronics in agriculture 2011-11, Vol.79 (2), p.169-179 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c416t-a75540dd9ab66f009176ba67e11a5df5f886ef597273bf4906e314ef20d93b193 |
---|---|
cites | cdi_FETCH-LOGICAL-c416t-a75540dd9ab66f009176ba67e11a5df5f886ef597273bf4906e314ef20d93b193 |
container_end_page | 179 |
container_issue | 2 |
container_start_page | 169 |
container_title | Computers and electronics in agriculture |
container_volume | 79 |
creator | Sharda, Ajay Fulton, John P McDonald, Timothy P Brodbeck, Christian J |
description | Automatic section control (ASC) has been readily adopted by US producers on sprayers because it can improve operator productivity and decrease overlap or input usage leading to economic savings while reducing environmental impacts. However, there is limited knowledge about nozzle flow dynamics when shutting ON/OFF of boom-sections or nozzles and the possible impact on application accuracy. Therefore, an investigation was conducted to evaluate system response in managing real-time nozzle off-rate and flow uniformity across the boom, for a typical agricultural sprayer using ASC. An 18.3-m sprayer was outfitted with commercially available individual nozzle and boom-section control. Tests were conducted to simulate sprayer moving out of point rows into a no-spray zone and then reentry into the spray zone by selecting two point row scenarios having 20° and 70° angles. Ten high frequency response pressure sensors were randomly mounted across the boom to measure nozzle pressure. The nozzle pressures were converted to nozzle flow, using the manufacturers pressure versus flow relationship, to calculate nozzle flow rate delay time, settling time, percent off-rate (percent difference between actual and target nozzle flow rate) and nozzle flow uniformity (CV), considering only ON boom-sections. Auto-boom scenarios were conducted with and with-out flow compensation while auto-nozzle scenarios were conducted without flow compensation. Results indicated that nozzle flow rate settling time varied from 0.4 to 14.4s and nozzle off-rate between 36.6% and +28.7% for 70° point row auto-boom tests when exiting and reentering point rows. When exiting point rows, over-application occurred whereas reentry resulted in under-application during flow compensated tests. Nozzle flow uniformity (CV) were more than 50% for a short duration ( |
doi_str_mv | 10.1016/j.compag.2011.09.006 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_963858384</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0168169911002092</els_id><sourcerecordid>963858384</sourcerecordid><originalsourceid>FETCH-LOGICAL-c416t-a75540dd9ab66f009176ba67e11a5df5f886ef597273bf4906e314ef20d93b193</originalsourceid><addsrcrecordid>eNp9kFFrFDEQxxdR8Kx-A8G8iE-7JtlssnkRpGhbKAjavjbkspMzRzY5k6zl-umbc4uPfZoZ-M3Mn1_TvCe4I5jwz_vOxPmgdx3FhHRYdhjzF82GjIK2gmDxstlUbGwJl_J18ybnPa6zHMWmufsJ2rfFzYBCfHjwgKyP92gJzsY0u3JE978hoCW7sEN6KXHWxRmUwRQXAzIxlBQ9qq3eJWcWX5akPcqHpI-Q8tvmldU-w7unetbcfv92c37ZXv-4uDr_et0aRnhptRgGhqdJ6i3nFmNJBN9qLoAQPUx2sOPIwQ5SUNFvLZOYQ08YWIon2W-J7M-aT-vdQ4p_FshFzS4b8F4HiEtWkvfjMPYjqyRbSZNizgmsOiQ363RUBKuTTbVXq011sqmwVNVmXfv49EBno71NOhiX_-_SgXJK_gX5sHJWR3VSktXtr3qIYYwZpQN_lqCsBqjEl5WAauyvg6SycRAMTC5V72qK7vmwjw-GoGE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>963858384</pqid></control><display><type>article</type><title>Real-time nozzle flow uniformity when using automatic section control on agricultural sprayers</title><source>Elsevier</source><creator>Sharda, Ajay ; Fulton, John P ; McDonald, Timothy P ; Brodbeck, Christian J</creator><creatorcontrib>Sharda, Ajay ; Fulton, John P ; McDonald, Timothy P ; Brodbeck, Christian J</creatorcontrib><description>Automatic section control (ASC) has been readily adopted by US producers on sprayers because it can improve operator productivity and decrease overlap or input usage leading to economic savings while reducing environmental impacts. However, there is limited knowledge about nozzle flow dynamics when shutting ON/OFF of boom-sections or nozzles and the possible impact on application accuracy. Therefore, an investigation was conducted to evaluate system response in managing real-time nozzle off-rate and flow uniformity across the boom, for a typical agricultural sprayer using ASC. An 18.3-m sprayer was outfitted with commercially available individual nozzle and boom-section control. Tests were conducted to simulate sprayer moving out of point rows into a no-spray zone and then reentry into the spray zone by selecting two point row scenarios having 20° and 70° angles. Ten high frequency response pressure sensors were randomly mounted across the boom to measure nozzle pressure. The nozzle pressures were converted to nozzle flow, using the manufacturers pressure versus flow relationship, to calculate nozzle flow rate delay time, settling time, percent off-rate (percent difference between actual and target nozzle flow rate) and nozzle flow uniformity (CV), considering only ON boom-sections. Auto-boom scenarios were conducted with and with-out flow compensation while auto-nozzle scenarios were conducted without flow compensation. Results indicated that nozzle flow rate settling time varied from 0.4 to 14.4s and nozzle off-rate between 36.6% and +28.7% for 70° point row auto-boom tests when exiting and reentering point rows. When exiting point rows, over-application occurred whereas reentry resulted in under-application during flow compensated tests. Nozzle flow uniformity (CV) were more than 50% for a short duration (<1.0s) when reentering point rows, during all tests. Compensation testing for 20° point row reentry highlighted the constraint of the control system to respond to certain situations where feedback response times could not match target rates rapidly set for the controller. Overall results indicated that system response time can impact nozzle off-rate and can vary with point row angle.</description><identifier>ISSN: 0168-1699</identifier><identifier>EISSN: 1872-7107</identifier><identifier>DOI: 10.1016/j.compag.2011.09.006</identifier><identifier>CODEN: CEAGE6</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Agronomy. Soil science and plant productions ; Biological and medical sciences ; Compensation ; Control systems ; Distribution ; environmental impact ; Fundamental and applied biological sciences. Psychology ; Liquid application ; Nozzle flow ; Nozzles ; Precision agriculture ; Reentry ; Settling ; Sprayers ; Uniformity ; Variability</subject><ispartof>Computers and electronics in agriculture, 2011-11, Vol.79 (2), p.169-179</ispartof><rights>2011 Elsevier B.V.</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c416t-a75540dd9ab66f009176ba67e11a5df5f886ef597273bf4906e314ef20d93b193</citedby><cites>FETCH-LOGICAL-c416t-a75540dd9ab66f009176ba67e11a5df5f886ef597273bf4906e314ef20d93b193</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=25262119$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Sharda, Ajay</creatorcontrib><creatorcontrib>Fulton, John P</creatorcontrib><creatorcontrib>McDonald, Timothy P</creatorcontrib><creatorcontrib>Brodbeck, Christian J</creatorcontrib><title>Real-time nozzle flow uniformity when using automatic section control on agricultural sprayers</title><title>Computers and electronics in agriculture</title><description>Automatic section control (ASC) has been readily adopted by US producers on sprayers because it can improve operator productivity and decrease overlap or input usage leading to economic savings while reducing environmental impacts. However, there is limited knowledge about nozzle flow dynamics when shutting ON/OFF of boom-sections or nozzles and the possible impact on application accuracy. Therefore, an investigation was conducted to evaluate system response in managing real-time nozzle off-rate and flow uniformity across the boom, for a typical agricultural sprayer using ASC. An 18.3-m sprayer was outfitted with commercially available individual nozzle and boom-section control. Tests were conducted to simulate sprayer moving out of point rows into a no-spray zone and then reentry into the spray zone by selecting two point row scenarios having 20° and 70° angles. Ten high frequency response pressure sensors were randomly mounted across the boom to measure nozzle pressure. The nozzle pressures were converted to nozzle flow, using the manufacturers pressure versus flow relationship, to calculate nozzle flow rate delay time, settling time, percent off-rate (percent difference between actual and target nozzle flow rate) and nozzle flow uniformity (CV), considering only ON boom-sections. Auto-boom scenarios were conducted with and with-out flow compensation while auto-nozzle scenarios were conducted without flow compensation. Results indicated that nozzle flow rate settling time varied from 0.4 to 14.4s and nozzle off-rate between 36.6% and +28.7% for 70° point row auto-boom tests when exiting and reentering point rows. When exiting point rows, over-application occurred whereas reentry resulted in under-application during flow compensated tests. Nozzle flow uniformity (CV) were more than 50% for a short duration (<1.0s) when reentering point rows, during all tests. Compensation testing for 20° point row reentry highlighted the constraint of the control system to respond to certain situations where feedback response times could not match target rates rapidly set for the controller. Overall results indicated that system response time can impact nozzle off-rate and can vary with point row angle.</description><subject>Agronomy. Soil science and plant productions</subject><subject>Biological and medical sciences</subject><subject>Compensation</subject><subject>Control systems</subject><subject>Distribution</subject><subject>environmental impact</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Liquid application</subject><subject>Nozzle flow</subject><subject>Nozzles</subject><subject>Precision agriculture</subject><subject>Reentry</subject><subject>Settling</subject><subject>Sprayers</subject><subject>Uniformity</subject><subject>Variability</subject><issn>0168-1699</issn><issn>1872-7107</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp9kFFrFDEQxxdR8Kx-A8G8iE-7JtlssnkRpGhbKAjavjbkspMzRzY5k6zl-umbc4uPfZoZ-M3Mn1_TvCe4I5jwz_vOxPmgdx3FhHRYdhjzF82GjIK2gmDxstlUbGwJl_J18ybnPa6zHMWmufsJ2rfFzYBCfHjwgKyP92gJzsY0u3JE978hoCW7sEN6KXHWxRmUwRQXAzIxlBQ9qq3eJWcWX5akPcqHpI-Q8tvmldU-w7unetbcfv92c37ZXv-4uDr_et0aRnhptRgGhqdJ6i3nFmNJBN9qLoAQPUx2sOPIwQ5SUNFvLZOYQ08YWIon2W-J7M-aT-vdQ4p_FshFzS4b8F4HiEtWkvfjMPYjqyRbSZNizgmsOiQ363RUBKuTTbVXq011sqmwVNVmXfv49EBno71NOhiX_-_SgXJK_gX5sHJWR3VSktXtr3qIYYwZpQN_lqCsBqjEl5WAauyvg6SycRAMTC5V72qK7vmwjw-GoGE</recordid><startdate>20111101</startdate><enddate>20111101</enddate><creator>Sharda, Ajay</creator><creator>Fulton, John P</creator><creator>McDonald, Timothy P</creator><creator>Brodbeck, Christian J</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>FBQ</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>8FD</scope><scope>FR3</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope></search><sort><creationdate>20111101</creationdate><title>Real-time nozzle flow uniformity when using automatic section control on agricultural sprayers</title><author>Sharda, Ajay ; Fulton, John P ; McDonald, Timothy P ; Brodbeck, Christian J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c416t-a75540dd9ab66f009176ba67e11a5df5f886ef597273bf4906e314ef20d93b193</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Agronomy. Soil science and plant productions</topic><topic>Biological and medical sciences</topic><topic>Compensation</topic><topic>Control systems</topic><topic>Distribution</topic><topic>environmental impact</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Liquid application</topic><topic>Nozzle flow</topic><topic>Nozzles</topic><topic>Precision agriculture</topic><topic>Reentry</topic><topic>Settling</topic><topic>Sprayers</topic><topic>Uniformity</topic><topic>Variability</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sharda, Ajay</creatorcontrib><creatorcontrib>Fulton, John P</creatorcontrib><creatorcontrib>McDonald, Timothy P</creatorcontrib><creatorcontrib>Brodbeck, Christian J</creatorcontrib><collection>AGRIS</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><jtitle>Computers and electronics in agriculture</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sharda, Ajay</au><au>Fulton, John P</au><au>McDonald, Timothy P</au><au>Brodbeck, Christian J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Real-time nozzle flow uniformity when using automatic section control on agricultural sprayers</atitle><jtitle>Computers and electronics in agriculture</jtitle><date>2011-11-01</date><risdate>2011</risdate><volume>79</volume><issue>2</issue><spage>169</spage><epage>179</epage><pages>169-179</pages><issn>0168-1699</issn><eissn>1872-7107</eissn><coden>CEAGE6</coden><abstract>Automatic section control (ASC) has been readily adopted by US producers on sprayers because it can improve operator productivity and decrease overlap or input usage leading to economic savings while reducing environmental impacts. However, there is limited knowledge about nozzle flow dynamics when shutting ON/OFF of boom-sections or nozzles and the possible impact on application accuracy. Therefore, an investigation was conducted to evaluate system response in managing real-time nozzle off-rate and flow uniformity across the boom, for a typical agricultural sprayer using ASC. An 18.3-m sprayer was outfitted with commercially available individual nozzle and boom-section control. Tests were conducted to simulate sprayer moving out of point rows into a no-spray zone and then reentry into the spray zone by selecting two point row scenarios having 20° and 70° angles. Ten high frequency response pressure sensors were randomly mounted across the boom to measure nozzle pressure. The nozzle pressures were converted to nozzle flow, using the manufacturers pressure versus flow relationship, to calculate nozzle flow rate delay time, settling time, percent off-rate (percent difference between actual and target nozzle flow rate) and nozzle flow uniformity (CV), considering only ON boom-sections. Auto-boom scenarios were conducted with and with-out flow compensation while auto-nozzle scenarios were conducted without flow compensation. Results indicated that nozzle flow rate settling time varied from 0.4 to 14.4s and nozzle off-rate between 36.6% and +28.7% for 70° point row auto-boom tests when exiting and reentering point rows. When exiting point rows, over-application occurred whereas reentry resulted in under-application during flow compensated tests. Nozzle flow uniformity (CV) were more than 50% for a short duration (<1.0s) when reentering point rows, during all tests. Compensation testing for 20° point row reentry highlighted the constraint of the control system to respond to certain situations where feedback response times could not match target rates rapidly set for the controller. Overall results indicated that system response time can impact nozzle off-rate and can vary with point row angle.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.compag.2011.09.006</doi><tpages>11</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0168-1699 |
ispartof | Computers and electronics in agriculture, 2011-11, Vol.79 (2), p.169-179 |
issn | 0168-1699 1872-7107 |
language | eng |
recordid | cdi_proquest_miscellaneous_963858384 |
source | Elsevier |
subjects | Agronomy. Soil science and plant productions Biological and medical sciences Compensation Control systems Distribution environmental impact Fundamental and applied biological sciences. Psychology Liquid application Nozzle flow Nozzles Precision agriculture Reentry Settling Sprayers Uniformity Variability |
title | Real-time nozzle flow uniformity when using automatic section control on agricultural sprayers |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T17%3A28%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Real-time%20nozzle%20flow%20uniformity%20when%20using%20automatic%20section%20control%20on%20agricultural%20sprayers&rft.jtitle=Computers%20and%20electronics%20in%20agriculture&rft.au=Sharda,%20Ajay&rft.date=2011-11-01&rft.volume=79&rft.issue=2&rft.spage=169&rft.epage=179&rft.pages=169-179&rft.issn=0168-1699&rft.eissn=1872-7107&rft.coden=CEAGE6&rft_id=info:doi/10.1016/j.compag.2011.09.006&rft_dat=%3Cproquest_cross%3E963858384%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c416t-a75540dd9ab66f009176ba67e11a5df5f886ef597273bf4906e314ef20d93b193%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=963858384&rft_id=info:pmid/&rfr_iscdi=true |