Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years

We report the outcome of 191 acetabular gritblasted titanium cups with a hemispherical design for press-fit insertion and coated with hydroxyapatite. The prosthesis was made of gritblasted titanium entirely coated with hydroxyapatite. 155 patients aged 15-78 years were operated on during the years 1...

Full description

Saved in:
Bibliographic Details
Published in:Acta orthopaedica 2002, Vol.73 (1), p.104-108
Main Authors: Reikerås, Olav, Gunderson, Ragnhild B
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c480t-b1bcc9b9e110c8962f38b534ed78186168c24806d38ad3004bd2caf915c24bae3
cites cdi_FETCH-LOGICAL-c480t-b1bcc9b9e110c8962f38b534ed78186168c24806d38ad3004bd2caf915c24bae3
container_end_page 108
container_issue 1
container_start_page 104
container_title Acta orthopaedica
container_volume 73
creator Reikerås, Olav
Gunderson, Ragnhild B
description We report the outcome of 191 acetabular gritblasted titanium cups with a hemispherical design for press-fit insertion and coated with hydroxyapatite. The prosthesis was made of gritblasted titanium entirely coated with hydroxyapatite. 155 patients aged 15-78 years were operated on during the years 1991-1993 and followed for 7-10 years. During this period, 39 cups were revised because of mechanical loosening, a further 9 had radiolucent lines and 2 focal osteolysis. None of these 11 patients had clinical symptoms. Failure was associated with age, wear and radiolucency/osteolysis. At revision, we found that the soft tissues were discolored, and that most of the coating had disappeared. This design of hydroxyapatite-coated cups has a high rate of debonding and failure.
doi_str_mv 10.1080/000164702317281503
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_11928902</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>71563626</sourcerecordid><originalsourceid>FETCH-LOGICAL-c480t-b1bcc9b9e110c8962f38b534ed78186168c24806d38ad3004bd2caf915c24bae3</originalsourceid><addsrcrecordid>eNp90E1r3DAQBmBRWpqP9g_0UHRpb05nJFuWQ3oIIR-FQC_tqQczkuXEQWttJJmw_74qu2kIgZwkxPMOmpexTwhHCBq-AQCqugUhsRUaG5Bv2D62dVNJpcXb__e23mMHKd0BSF138J7tIXZCdyD22Z8LmvwSHQ8jvzrlNlCe5hseZk78Jk7ZeErZDZysy2QWT5HbZX3MsWn4ulg358TH4H14KGoMkbcVAt84iukDezeST-7j7jxkvy_Of51dVdc_L3-cnV5XttaQK4PG2s50DhGs7pQYpTaNrN3QatQKlbaiQDVITYMEqM0gLI0dNuXdkJOH7Ot27jqG-8Wl3K-mZJ33NLuwpL7FRkklVIFiC20MKUU39us4rShueoT-X6X9y0pL6PNu-mJWbniK7Dos4MsOULLkx0izndKTk00NLWBx37dumktPK3oI0Q99po0P8TEkX_3IybP8rSOfby1F19-FJc6l4tf2-AuRZaF2</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71563626</pqid></control><display><type>article</type><title>Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years</title><source>SPORTDiscus with Full Text</source><creator>Reikerås, Olav ; Gunderson, Ragnhild B</creator><creatorcontrib>Reikerås, Olav ; Gunderson, Ragnhild B</creatorcontrib><description>We report the outcome of 191 acetabular gritblasted titanium cups with a hemispherical design for press-fit insertion and coated with hydroxyapatite. The prosthesis was made of gritblasted titanium entirely coated with hydroxyapatite. 155 patients aged 15-78 years were operated on during the years 1991-1993 and followed for 7-10 years. During this period, 39 cups were revised because of mechanical loosening, a further 9 had radiolucent lines and 2 focal osteolysis. None of these 11 patients had clinical symptoms. Failure was associated with age, wear and radiolucency/osteolysis. At revision, we found that the soft tissues were discolored, and that most of the coating had disappeared. This design of hydroxyapatite-coated cups has a high rate of debonding and failure.</description><identifier>ISSN: 1745-3674</identifier><identifier>ISSN: 0001-6470</identifier><identifier>EISSN: 1745-3682</identifier><identifier>DOI: 10.1080/000164702317281503</identifier><identifier>PMID: 11928902</identifier><identifier>CODEN: AOSAAK</identifier><language>eng</language><publisher>Basingstoke: Informa UK Ltd</publisher><subject>Adolescent ; Adult ; Aged ; Arthroplasty, Replacement, Hip - instrumentation ; Arthroplasty, Replacement, Hip - methods ; Biological and medical sciences ; Coated Materials, Biocompatible ; Confidence Intervals ; Female ; Follow-Up Studies ; Hip Prosthesis ; Humans ; Male ; Medical sciences ; Middle Aged ; Odds Ratio ; Orthopedic surgery ; Probability ; Proportional Hazards Models ; Prosthesis Design ; Prosthesis Failure ; Reoperation ; Retrospective Studies ; Risk Assessment ; Risk Factors ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Time Factors ; Titanium</subject><ispartof>Acta orthopaedica, 2002, Vol.73 (1), p.104-108</ispartof><rights>2002 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 2002</rights><rights>2002 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c480t-b1bcc9b9e110c8962f38b534ed78186168c24806d38ad3004bd2caf915c24bae3</citedby><cites>FETCH-LOGICAL-c480t-b1bcc9b9e110c8962f38b534ed78186168c24806d38ad3004bd2caf915c24bae3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4022,27922,27923,27924</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=13540701$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11928902$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Reikerås, Olav</creatorcontrib><creatorcontrib>Gunderson, Ragnhild B</creatorcontrib><title>Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years</title><title>Acta orthopaedica</title><addtitle>Acta Orthop Scand</addtitle><description>We report the outcome of 191 acetabular gritblasted titanium cups with a hemispherical design for press-fit insertion and coated with hydroxyapatite. The prosthesis was made of gritblasted titanium entirely coated with hydroxyapatite. 155 patients aged 15-78 years were operated on during the years 1991-1993 and followed for 7-10 years. During this period, 39 cups were revised because of mechanical loosening, a further 9 had radiolucent lines and 2 focal osteolysis. None of these 11 patients had clinical symptoms. Failure was associated with age, wear and radiolucency/osteolysis. At revision, we found that the soft tissues were discolored, and that most of the coating had disappeared. This design of hydroxyapatite-coated cups has a high rate of debonding and failure.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Arthroplasty, Replacement, Hip - instrumentation</subject><subject>Arthroplasty, Replacement, Hip - methods</subject><subject>Biological and medical sciences</subject><subject>Coated Materials, Biocompatible</subject><subject>Confidence Intervals</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Hip Prosthesis</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Odds Ratio</subject><subject>Orthopedic surgery</subject><subject>Probability</subject><subject>Proportional Hazards Models</subject><subject>Prosthesis Design</subject><subject>Prosthesis Failure</subject><subject>Reoperation</subject><subject>Retrospective Studies</subject><subject>Risk Assessment</subject><subject>Risk Factors</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Time Factors</subject><subject>Titanium</subject><issn>1745-3674</issn><issn>0001-6470</issn><issn>1745-3682</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNp90E1r3DAQBmBRWpqP9g_0UHRpb05nJFuWQ3oIIR-FQC_tqQczkuXEQWttJJmw_74qu2kIgZwkxPMOmpexTwhHCBq-AQCqugUhsRUaG5Bv2D62dVNJpcXb__e23mMHKd0BSF138J7tIXZCdyD22Z8LmvwSHQ8jvzrlNlCe5hseZk78Jk7ZeErZDZysy2QWT5HbZX3MsWn4ulg358TH4H14KGoMkbcVAt84iukDezeST-7j7jxkvy_Of51dVdc_L3-cnV5XttaQK4PG2s50DhGs7pQYpTaNrN3QatQKlbaiQDVITYMEqM0gLI0dNuXdkJOH7Ot27jqG-8Wl3K-mZJ33NLuwpL7FRkklVIFiC20MKUU39us4rShueoT-X6X9y0pL6PNu-mJWbniK7Dos4MsOULLkx0izndKTk00NLWBx37dumktPK3oI0Q99po0P8TEkX_3IybP8rSOfby1F19-FJc6l4tf2-AuRZaF2</recordid><startdate>2002</startdate><enddate>2002</enddate><creator>Reikerås, Olav</creator><creator>Gunderson, Ragnhild B</creator><general>Informa UK Ltd</general><general>Taylor &amp; Francis</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>2002</creationdate><title>Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years</title><author>Reikerås, Olav ; Gunderson, Ragnhild B</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c480t-b1bcc9b9e110c8962f38b534ed78186168c24806d38ad3004bd2caf915c24bae3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Arthroplasty, Replacement, Hip - instrumentation</topic><topic>Arthroplasty, Replacement, Hip - methods</topic><topic>Biological and medical sciences</topic><topic>Coated Materials, Biocompatible</topic><topic>Confidence Intervals</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Hip Prosthesis</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Odds Ratio</topic><topic>Orthopedic surgery</topic><topic>Probability</topic><topic>Proportional Hazards Models</topic><topic>Prosthesis Design</topic><topic>Prosthesis Failure</topic><topic>Reoperation</topic><topic>Retrospective Studies</topic><topic>Risk Assessment</topic><topic>Risk Factors</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Time Factors</topic><topic>Titanium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Reikerås, Olav</creatorcontrib><creatorcontrib>Gunderson, Ragnhild B</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Acta orthopaedica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Reikerås, Olav</au><au>Gunderson, Ragnhild B</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years</atitle><jtitle>Acta orthopaedica</jtitle><addtitle>Acta Orthop Scand</addtitle><date>2002</date><risdate>2002</risdate><volume>73</volume><issue>1</issue><spage>104</spage><epage>108</epage><pages>104-108</pages><issn>1745-3674</issn><issn>0001-6470</issn><eissn>1745-3682</eissn><coden>AOSAAK</coden><abstract>We report the outcome of 191 acetabular gritblasted titanium cups with a hemispherical design for press-fit insertion and coated with hydroxyapatite. The prosthesis was made of gritblasted titanium entirely coated with hydroxyapatite. 155 patients aged 15-78 years were operated on during the years 1991-1993 and followed for 7-10 years. During this period, 39 cups were revised because of mechanical loosening, a further 9 had radiolucent lines and 2 focal osteolysis. None of these 11 patients had clinical symptoms. Failure was associated with age, wear and radiolucency/osteolysis. At revision, we found that the soft tissues were discolored, and that most of the coating had disappeared. This design of hydroxyapatite-coated cups has a high rate of debonding and failure.</abstract><cop>Basingstoke</cop><pub>Informa UK Ltd</pub><pmid>11928902</pmid><doi>10.1080/000164702317281503</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1745-3674
ispartof Acta orthopaedica, 2002, Vol.73 (1), p.104-108
issn 1745-3674
0001-6470
1745-3682
language eng
recordid cdi_pubmed_primary_11928902
source SPORTDiscus with Full Text
subjects Adolescent
Adult
Aged
Arthroplasty, Replacement, Hip - instrumentation
Arthroplasty, Replacement, Hip - methods
Biological and medical sciences
Coated Materials, Biocompatible
Confidence Intervals
Female
Follow-Up Studies
Hip Prosthesis
Humans
Male
Medical sciences
Middle Aged
Odds Ratio
Orthopedic surgery
Probability
Proportional Hazards Models
Prosthesis Design
Prosthesis Failure
Reoperation
Retrospective Studies
Risk Assessment
Risk Factors
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Time Factors
Titanium
title Failure of HA coating on a gritblasted acetabular cup: 155 patients followed for 7-10 years
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T03%3A29%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Failure%20of%20HA%20coating%20on%20a%20gritblasted%20acetabular%20cup:%20155%20patients%20followed%20for%207-10%20years&rft.jtitle=Acta%20orthopaedica&rft.au=Reiker%C3%A5s,%20Olav&rft.date=2002&rft.volume=73&rft.issue=1&rft.spage=104&rft.epage=108&rft.pages=104-108&rft.issn=1745-3674&rft.eissn=1745-3682&rft.coden=AOSAAK&rft_id=info:doi/10.1080/000164702317281503&rft_dat=%3Cproquest_pubme%3E71563626%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c480t-b1bcc9b9e110c8962f38b534ed78186168c24806d38ad3004bd2caf915c24bae3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=71563626&rft_id=info:pmid/11928902&rfr_iscdi=true