Rapid Human Immunodeficiency Virus Test Quality Assurance Practices and Outcomes among Testing Sites Affiliated with 17 Public Health Departments
Rapid human immunodeficiency virus testing is often conducted in nonclinical settings by staff with limited training, so quality assurance (QA) monitoring is critical to ensure accuracy of test results. Rapid tests (n = 86,749) were generally conducted according to manufacturers' instructions,...
Saved in:
Published in: | Journal of Clinical Microbiology 2009-10, Vol.47 (10), p.3333-3335, Article 3333 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c495t-a9e159b8b00fdfba57c4d4a7078bf3c244fac8ec87a8eb3f699458543def7b673 |
---|---|
cites | cdi_FETCH-LOGICAL-c495t-a9e159b8b00fdfba57c4d4a7078bf3c244fac8ec87a8eb3f699458543def7b673 |
container_end_page | 3335 |
container_issue | 10 |
container_start_page | 3333 |
container_title | Journal of Clinical Microbiology |
container_volume | 47 |
creator | Wesolowski, Laura G Ethridge, Steven F Martin, Eugene G Cadoff, Evan M MacKellar, Duncan A |
description | Rapid human immunodeficiency virus testing is often conducted in nonclinical settings by staff with limited training, so quality assurance (QA) monitoring is critical to ensure accuracy of test results. Rapid tests (n = 86,749) were generally conducted according to manufacturers' instructions, but ongoing testing competency assessments and on-site QA monitoring were not uniformly conducted. |
doi_str_mv | 10.1128/JCM.01504-09 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_19692557</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>21284827</sourcerecordid><originalsourceid>FETCH-LOGICAL-c495t-a9e159b8b00fdfba57c4d4a7078bf3c244fac8ec87a8eb3f699458543def7b673</originalsourceid><addsrcrecordid>eNp9kUtvEzEUhUcIRENgxxqsSsCGFNtjj8cbpCg8UlTUQlvEzrrjsRNX8wi2hyo_g3-Mp4nKQwJvLF9_9557dLLsMcFHhNDy1YfFxyNMOGYzLO9kE4JlOSsK_PVuNsFY8hkhuTjIHoRwhTFhjPP72QGRhaSci0n24zNsXI2WQwsdOm7boetrY512ptNb9MX5IaALEyL6NEDj4hbNQxg8dNqgMw86Om0Cgq5Gp0PUfTs-2r5b3fS4dJ-7mGpza13jIJoaXbu4RkSgs6FqnEZLA00qvDEb8LE1XQwPs3sWmmAe7e9pdvnu7cViOTs5fX-8mJ_MNJM8zkAawmVVVhjb2lbAhWY1A4FFWdlcU8Ys6NLoUkBpqtwWUjJecpYne6IqRD7NXu_mboaqNbVO2h4atfGuBb9VPTj150_n1mrVf1dU8CLNSgNe7Af4_tuQ_KrWBW2aBjrTD0GJPC8wFpgl8vl_SZpyZCUdd3q5A7XvQ_DG3q5DsBrTViltdZO2wjLhT3638Avex5uAZ3sAgobGjsG5cMtRIqWgMk8c_UtXuwjR9aNz1_xL_XDXtHar9bXzRkFo1ZVuFRNjRz6eafZ0B1noFax8Ur88p5jkmBRlwWiR_wRjCdq4</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>21284827</pqid></control><display><type>article</type><title>Rapid Human Immunodeficiency Virus Test Quality Assurance Practices and Outcomes among Testing Sites Affiliated with 17 Public Health Departments</title><source>PubMed (Medline)</source><source>American Society for Microbiology Journals</source><creator>Wesolowski, Laura G ; Ethridge, Steven F ; Martin, Eugene G ; Cadoff, Evan M ; MacKellar, Duncan A</creator><creatorcontrib>Wesolowski, Laura G ; Ethridge, Steven F ; Martin, Eugene G ; Cadoff, Evan M ; MacKellar, Duncan A</creatorcontrib><description>Rapid human immunodeficiency virus testing is often conducted in nonclinical settings by staff with limited training, so quality assurance (QA) monitoring is critical to ensure accuracy of test results. Rapid tests (n = 86,749) were generally conducted according to manufacturers' instructions, but ongoing testing competency assessments and on-site QA monitoring were not uniformly conducted.</description><identifier>ISSN: 0095-1137</identifier><identifier>EISSN: 1098-660X</identifier><identifier>DOI: 10.1128/JCM.01504-09</identifier><identifier>PMID: 19692557</identifier><identifier>CODEN: JCMIDW</identifier><language>eng</language><publisher>Washington, DC: American Society for Microbiology</publisher><subject>Biological and medical sciences ; Fundamental and applied biological sciences. Psychology ; Health Services Research ; HIV - isolation & purification ; HIV Infections - diagnosis ; Human immunodeficiency virus ; Humans ; Medical Laboratory Science - methods ; Medical Laboratory Science - standards ; Microbiology ; Miscellaneous ; Public Health ; Quality Assurance, Health Care - methods ; Virology ; Virology - methods</subject><ispartof>Journal of Clinical Microbiology, 2009-10, Vol.47 (10), p.3333-3335, Article 3333</ispartof><rights>2009 INIST-CNRS</rights><rights>Copyright © 2009, American Society for Microbiology</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c495t-a9e159b8b00fdfba57c4d4a7078bf3c244fac8ec87a8eb3f699458543def7b673</citedby><cites>FETCH-LOGICAL-c495t-a9e159b8b00fdfba57c4d4a7078bf3c244fac8ec87a8eb3f699458543def7b673</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC2756945/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC2756945/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,3188,3189,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=21997293$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19692557$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wesolowski, Laura G</creatorcontrib><creatorcontrib>Ethridge, Steven F</creatorcontrib><creatorcontrib>Martin, Eugene G</creatorcontrib><creatorcontrib>Cadoff, Evan M</creatorcontrib><creatorcontrib>MacKellar, Duncan A</creatorcontrib><title>Rapid Human Immunodeficiency Virus Test Quality Assurance Practices and Outcomes among Testing Sites Affiliated with 17 Public Health Departments</title><title>Journal of Clinical Microbiology</title><addtitle>J Clin Microbiol</addtitle><description>Rapid human immunodeficiency virus testing is often conducted in nonclinical settings by staff with limited training, so quality assurance (QA) monitoring is critical to ensure accuracy of test results. Rapid tests (n = 86,749) were generally conducted according to manufacturers' instructions, but ongoing testing competency assessments and on-site QA monitoring were not uniformly conducted.</description><subject>Biological and medical sciences</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Health Services Research</subject><subject>HIV - isolation & purification</subject><subject>HIV Infections - diagnosis</subject><subject>Human immunodeficiency virus</subject><subject>Humans</subject><subject>Medical Laboratory Science - methods</subject><subject>Medical Laboratory Science - standards</subject><subject>Microbiology</subject><subject>Miscellaneous</subject><subject>Public Health</subject><subject>Quality Assurance, Health Care - methods</subject><subject>Virology</subject><subject>Virology - methods</subject><issn>0095-1137</issn><issn>1098-660X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNp9kUtvEzEUhUcIRENgxxqsSsCGFNtjj8cbpCg8UlTUQlvEzrrjsRNX8wi2hyo_g3-Mp4nKQwJvLF9_9557dLLsMcFHhNDy1YfFxyNMOGYzLO9kE4JlOSsK_PVuNsFY8hkhuTjIHoRwhTFhjPP72QGRhaSci0n24zNsXI2WQwsdOm7boetrY512ptNb9MX5IaALEyL6NEDj4hbNQxg8dNqgMw86Om0Cgq5Gp0PUfTs-2r5b3fS4dJ-7mGpza13jIJoaXbu4RkSgs6FqnEZLA00qvDEb8LE1XQwPs3sWmmAe7e9pdvnu7cViOTs5fX-8mJ_MNJM8zkAawmVVVhjb2lbAhWY1A4FFWdlcU8Ys6NLoUkBpqtwWUjJecpYne6IqRD7NXu_mboaqNbVO2h4atfGuBb9VPTj150_n1mrVf1dU8CLNSgNe7Af4_tuQ_KrWBW2aBjrTD0GJPC8wFpgl8vl_SZpyZCUdd3q5A7XvQ_DG3q5DsBrTViltdZO2wjLhT3638Avex5uAZ3sAgobGjsG5cMtRIqWgMk8c_UtXuwjR9aNz1_xL_XDXtHar9bXzRkFo1ZVuFRNjRz6eafZ0B1noFax8Ur88p5jkmBRlwWiR_wRjCdq4</recordid><startdate>20091001</startdate><enddate>20091001</enddate><creator>Wesolowski, Laura G</creator><creator>Ethridge, Steven F</creator><creator>Martin, Eugene G</creator><creator>Cadoff, Evan M</creator><creator>MacKellar, Duncan A</creator><general>American Society for Microbiology</general><general>American Society for Microbiology (ASM)</general><scope>FBQ</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7T5</scope><scope>7U9</scope><scope>H94</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20091001</creationdate><title>Rapid Human Immunodeficiency Virus Test Quality Assurance Practices and Outcomes among Testing Sites Affiliated with 17 Public Health Departments</title><author>Wesolowski, Laura G ; Ethridge, Steven F ; Martin, Eugene G ; Cadoff, Evan M ; MacKellar, Duncan A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c495t-a9e159b8b00fdfba57c4d4a7078bf3c244fac8ec87a8eb3f699458543def7b673</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Biological and medical sciences</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Health Services Research</topic><topic>HIV - isolation & purification</topic><topic>HIV Infections - diagnosis</topic><topic>Human immunodeficiency virus</topic><topic>Humans</topic><topic>Medical Laboratory Science - methods</topic><topic>Medical Laboratory Science - standards</topic><topic>Microbiology</topic><topic>Miscellaneous</topic><topic>Public Health</topic><topic>Quality Assurance, Health Care - methods</topic><topic>Virology</topic><topic>Virology - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wesolowski, Laura G</creatorcontrib><creatorcontrib>Ethridge, Steven F</creatorcontrib><creatorcontrib>Martin, Eugene G</creatorcontrib><creatorcontrib>Cadoff, Evan M</creatorcontrib><creatorcontrib>MacKellar, Duncan A</creatorcontrib><collection>AGRIS</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Immunology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of Clinical Microbiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wesolowski, Laura G</au><au>Ethridge, Steven F</au><au>Martin, Eugene G</au><au>Cadoff, Evan M</au><au>MacKellar, Duncan A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid Human Immunodeficiency Virus Test Quality Assurance Practices and Outcomes among Testing Sites Affiliated with 17 Public Health Departments</atitle><jtitle>Journal of Clinical Microbiology</jtitle><addtitle>J Clin Microbiol</addtitle><date>2009-10-01</date><risdate>2009</risdate><volume>47</volume><issue>10</issue><spage>3333</spage><epage>3335</epage><pages>3333-3335</pages><artnum>3333</artnum><issn>0095-1137</issn><eissn>1098-660X</eissn><coden>JCMIDW</coden><abstract>Rapid human immunodeficiency virus testing is often conducted in nonclinical settings by staff with limited training, so quality assurance (QA) monitoring is critical to ensure accuracy of test results. Rapid tests (n = 86,749) were generally conducted according to manufacturers' instructions, but ongoing testing competency assessments and on-site QA monitoring were not uniformly conducted.</abstract><cop>Washington, DC</cop><pub>American Society for Microbiology</pub><pmid>19692557</pmid><doi>10.1128/JCM.01504-09</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0095-1137 |
ispartof | Journal of Clinical Microbiology, 2009-10, Vol.47 (10), p.3333-3335, Article 3333 |
issn | 0095-1137 1098-660X |
language | eng |
recordid | cdi_pubmed_primary_19692557 |
source | PubMed (Medline); American Society for Microbiology Journals |
subjects | Biological and medical sciences Fundamental and applied biological sciences. Psychology Health Services Research HIV - isolation & purification HIV Infections - diagnosis Human immunodeficiency virus Humans Medical Laboratory Science - methods Medical Laboratory Science - standards Microbiology Miscellaneous Public Health Quality Assurance, Health Care - methods Virology Virology - methods |
title | Rapid Human Immunodeficiency Virus Test Quality Assurance Practices and Outcomes among Testing Sites Affiliated with 17 Public Health Departments |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T13%3A03%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20Human%20Immunodeficiency%20Virus%20Test%20Quality%20Assurance%20Practices%20and%20Outcomes%20among%20Testing%20Sites%20Affiliated%20with%2017%20Public%20Health%20Departments&rft.jtitle=Journal%20of%20Clinical%20Microbiology&rft.au=Wesolowski,%20Laura%20G&rft.date=2009-10-01&rft.volume=47&rft.issue=10&rft.spage=3333&rft.epage=3335&rft.pages=3333-3335&rft.artnum=3333&rft.issn=0095-1137&rft.eissn=1098-660X&rft.coden=JCMIDW&rft_id=info:doi/10.1128/JCM.01504-09&rft_dat=%3Cproquest_pubme%3E21284827%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c495t-a9e159b8b00fdfba57c4d4a7078bf3c244fac8ec87a8eb3f699458543def7b673%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=21284827&rft_id=info:pmid/19692557&rfr_iscdi=true |