Loading…
Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy
We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotatio...
Saved in:
Published in: | Applied optics. Optical technology and biomedical optics 2011-04, Vol.50 (12), p.1770 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13 |
---|---|
cites | |
container_end_page | |
container_issue | 12 |
container_start_page | 1770 |
container_title | Applied optics. Optical technology and biomedical optics |
container_volume | 50 |
creator | Kliewer, Christopher J Gao, Yi Seeger, Thomas Patterson, Brian D Farrow, Roger L Settersten, Thomas B |
description | We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotational CARS (RCARS) spectra, corresponding to 330 spatially resolved volume elements in the probe volume. Signal levels are sufficient for the collection of single-laser-pulse images at temperatures of up to approximately 1200 K and shot-averaged images at flame temperatures, demonstrated at 2100 K. The precision of picosecond pure-rotational 1D imaging CARS is assessed by acquiring a series of 100 single-laser-pulse images in a heated flow of N(2) from 410 K-1200 K and evaluating a single volume element for temperature in each image. Accuracy is demonstrated by comparing temperatures from the evaluated averaged spectra to thermocouple readings in the heated flow. Deviations from the thermocouple of |
doi_str_mv | 10.1364/AO.50.001770 |
format | article |
fullrecord | <record><control><sourceid>pubmed</sourceid><recordid>TN_cdi_pubmed_primary_21509070</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>21509070</sourcerecordid><originalsourceid>FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13</originalsourceid><addsrcrecordid>eNo1kEtLAzEUhYMgtlZ3riV_IPUmmZl0lqWoFQrF17rkWaOdZEgyQsEfb-tjcw6Xw_ngHoSuKEwpb6qb-XpawxSACgEnaMxoXRNOm3qEznN-B-B11YozNDoE0IKAMfp6HGQovsjiPy2OwRLjOxuyj0HusO_k1octHvJRe69jtjoGg80gd0SlKI2Sh7MfkiUpHik_PR3fbLKh4CObPJf4YTN-kp0MOPdWlxSzjv3-Ap06ucv28s8n6PXu9mWxJKv1_cNiviKatVCIloJzY6GxoJxh3HLBoNEOTMNcRZWctabmzgBjrGqcaSkowVo3m4FiVFM-Qde_3H5QnTWbPh0eS_vN_wz8G4WJYBg</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy</title><source>OSA Publishing</source><creator>Kliewer, Christopher J ; Gao, Yi ; Seeger, Thomas ; Patterson, Brian D ; Farrow, Roger L ; Settersten, Thomas B</creator><creatorcontrib>Kliewer, Christopher J ; Gao, Yi ; Seeger, Thomas ; Patterson, Brian D ; Farrow, Roger L ; Settersten, Thomas B</creatorcontrib><description>We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotational CARS (RCARS) spectra, corresponding to 330 spatially resolved volume elements in the probe volume. Signal levels are sufficient for the collection of single-laser-pulse images at temperatures of up to approximately 1200 K and shot-averaged images at flame temperatures, demonstrated at 2100 K. The precision of picosecond pure-rotational 1D imaging CARS is assessed by acquiring a series of 100 single-laser-pulse images in a heated flow of N(2) from 410 K-1200 K and evaluating a single volume element for temperature in each image. Accuracy is demonstrated by comparing temperatures from the evaluated averaged spectra to thermocouple readings in the heated flow. Deviations from the thermocouple of <30 K in the evaluated temperature were found at up to 1205 K. Accuracy and single-shot precision are compared to those reported for single-point nanosecond dual-broadband pure-RCARS and nanosecond 1D vibrational CARS.</description><identifier>EISSN: 2155-3165</identifier><identifier>DOI: 10.1364/AO.50.001770</identifier><identifier>PMID: 21509070</identifier><language>eng</language><publisher>United States</publisher><ispartof>Applied optics. Optical technology and biomedical optics, 2011-04, Vol.50 (12), p.1770</ispartof><rights>2011 Optical Society of America</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21509070$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kliewer, Christopher J</creatorcontrib><creatorcontrib>Gao, Yi</creatorcontrib><creatorcontrib>Seeger, Thomas</creatorcontrib><creatorcontrib>Patterson, Brian D</creatorcontrib><creatorcontrib>Farrow, Roger L</creatorcontrib><creatorcontrib>Settersten, Thomas B</creatorcontrib><title>Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy</title><title>Applied optics. Optical technology and biomedical optics</title><addtitle>Appl Opt</addtitle><description>We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotational CARS (RCARS) spectra, corresponding to 330 spatially resolved volume elements in the probe volume. Signal levels are sufficient for the collection of single-laser-pulse images at temperatures of up to approximately 1200 K and shot-averaged images at flame temperatures, demonstrated at 2100 K. The precision of picosecond pure-rotational 1D imaging CARS is assessed by acquiring a series of 100 single-laser-pulse images in a heated flow of N(2) from 410 K-1200 K and evaluating a single volume element for temperature in each image. Accuracy is demonstrated by comparing temperatures from the evaluated averaged spectra to thermocouple readings in the heated flow. Deviations from the thermocouple of <30 K in the evaluated temperature were found at up to 1205 K. Accuracy and single-shot precision are compared to those reported for single-point nanosecond dual-broadband pure-RCARS and nanosecond 1D vibrational CARS.</description><issn>2155-3165</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNo1kEtLAzEUhYMgtlZ3riV_IPUmmZl0lqWoFQrF17rkWaOdZEgyQsEfb-tjcw6Xw_ngHoSuKEwpb6qb-XpawxSACgEnaMxoXRNOm3qEznN-B-B11YozNDoE0IKAMfp6HGQovsjiPy2OwRLjOxuyj0HusO_k1octHvJRe69jtjoGg80gd0SlKI2Sh7MfkiUpHik_PR3fbLKh4CObPJf4YTN-kp0MOPdWlxSzjv3-Ap06ucv28s8n6PXu9mWxJKv1_cNiviKatVCIloJzY6GxoJxh3HLBoNEOTMNcRZWctabmzgBjrGqcaSkowVo3m4FiVFM-Qde_3H5QnTWbPh0eS_vN_wz8G4WJYBg</recordid><startdate>20110420</startdate><enddate>20110420</enddate><creator>Kliewer, Christopher J</creator><creator>Gao, Yi</creator><creator>Seeger, Thomas</creator><creator>Patterson, Brian D</creator><creator>Farrow, Roger L</creator><creator>Settersten, Thomas B</creator><scope>NPM</scope></search><sort><creationdate>20110420</creationdate><title>Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy</title><author>Kliewer, Christopher J ; Gao, Yi ; Seeger, Thomas ; Patterson, Brian D ; Farrow, Roger L ; Settersten, Thomas B</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kliewer, Christopher J</creatorcontrib><creatorcontrib>Gao, Yi</creatorcontrib><creatorcontrib>Seeger, Thomas</creatorcontrib><creatorcontrib>Patterson, Brian D</creatorcontrib><creatorcontrib>Farrow, Roger L</creatorcontrib><creatorcontrib>Settersten, Thomas B</creatorcontrib><collection>PubMed</collection><jtitle>Applied optics. Optical technology and biomedical optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kliewer, Christopher J</au><au>Gao, Yi</au><au>Seeger, Thomas</au><au>Patterson, Brian D</au><au>Farrow, Roger L</au><au>Settersten, Thomas B</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy</atitle><jtitle>Applied optics. Optical technology and biomedical optics</jtitle><addtitle>Appl Opt</addtitle><date>2011-04-20</date><risdate>2011</risdate><volume>50</volume><issue>12</issue><spage>1770</spage><pages>1770-</pages><eissn>2155-3165</eissn><abstract>We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotational CARS (RCARS) spectra, corresponding to 330 spatially resolved volume elements in the probe volume. Signal levels are sufficient for the collection of single-laser-pulse images at temperatures of up to approximately 1200 K and shot-averaged images at flame temperatures, demonstrated at 2100 K. The precision of picosecond pure-rotational 1D imaging CARS is assessed by acquiring a series of 100 single-laser-pulse images in a heated flow of N(2) from 410 K-1200 K and evaluating a single volume element for temperature in each image. Accuracy is demonstrated by comparing temperatures from the evaluated averaged spectra to thermocouple readings in the heated flow. Deviations from the thermocouple of <30 K in the evaluated temperature were found at up to 1205 K. Accuracy and single-shot precision are compared to those reported for single-point nanosecond dual-broadband pure-RCARS and nanosecond 1D vibrational CARS.</abstract><cop>United States</cop><pmid>21509070</pmid><doi>10.1364/AO.50.001770</doi></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2155-3165 |
ispartof | Applied optics. Optical technology and biomedical optics, 2011-04, Vol.50 (12), p.1770 |
issn | 2155-3165 |
language | eng |
recordid | cdi_pubmed_primary_21509070 |
source | OSA Publishing |
title | Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T00%3A11%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Quantitative%20one-dimensional%20imaging%20using%20picosecond%20dual-broadband%20pure-rotational%20coherent%20anti-Stokes%20Raman%20spectroscopy&rft.jtitle=Applied%20optics.%20Optical%20technology%20and%20biomedical%20optics&rft.au=Kliewer,%20Christopher%20J&rft.date=2011-04-20&rft.volume=50&rft.issue=12&rft.spage=1770&rft.pages=1770-&rft.eissn=2155-3165&rft_id=info:doi/10.1364/AO.50.001770&rft_dat=%3Cpubmed%3E21509070%3C/pubmed%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/21509070&rfr_iscdi=true |