Loading…

Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy

We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotatio...

Full description

Saved in:
Bibliographic Details
Published in:Applied optics. Optical technology and biomedical optics 2011-04, Vol.50 (12), p.1770
Main Authors: Kliewer, Christopher J, Gao, Yi, Seeger, Thomas, Patterson, Brian D, Farrow, Roger L, Settersten, Thomas B
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13
cites
container_end_page
container_issue 12
container_start_page 1770
container_title Applied optics. Optical technology and biomedical optics
container_volume 50
creator Kliewer, Christopher J
Gao, Yi
Seeger, Thomas
Patterson, Brian D
Farrow, Roger L
Settersten, Thomas B
description We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotational CARS (RCARS) spectra, corresponding to 330 spatially resolved volume elements in the probe volume. Signal levels are sufficient for the collection of single-laser-pulse images at temperatures of up to approximately 1200 K and shot-averaged images at flame temperatures, demonstrated at 2100 K. The precision of picosecond pure-rotational 1D imaging CARS is assessed by acquiring a series of 100 single-laser-pulse images in a heated flow of N(2) from 410 K-1200 K and evaluating a single volume element for temperature in each image. Accuracy is demonstrated by comparing temperatures from the evaluated averaged spectra to thermocouple readings in the heated flow. Deviations from the thermocouple of
doi_str_mv 10.1364/AO.50.001770
format article
fullrecord <record><control><sourceid>pubmed</sourceid><recordid>TN_cdi_pubmed_primary_21509070</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>21509070</sourcerecordid><originalsourceid>FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13</originalsourceid><addsrcrecordid>eNo1kEtLAzEUhYMgtlZ3riV_IPUmmZl0lqWoFQrF17rkWaOdZEgyQsEfb-tjcw6Xw_ngHoSuKEwpb6qb-XpawxSACgEnaMxoXRNOm3qEznN-B-B11YozNDoE0IKAMfp6HGQovsjiPy2OwRLjOxuyj0HusO_k1octHvJRe69jtjoGg80gd0SlKI2Sh7MfkiUpHik_PR3fbLKh4CObPJf4YTN-kp0MOPdWlxSzjv3-Ap06ucv28s8n6PXu9mWxJKv1_cNiviKatVCIloJzY6GxoJxh3HLBoNEOTMNcRZWctabmzgBjrGqcaSkowVo3m4FiVFM-Qde_3H5QnTWbPh0eS_vN_wz8G4WJYBg</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy</title><source>OSA Publishing</source><creator>Kliewer, Christopher J ; Gao, Yi ; Seeger, Thomas ; Patterson, Brian D ; Farrow, Roger L ; Settersten, Thomas B</creator><creatorcontrib>Kliewer, Christopher J ; Gao, Yi ; Seeger, Thomas ; Patterson, Brian D ; Farrow, Roger L ; Settersten, Thomas B</creatorcontrib><description>We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotational CARS (RCARS) spectra, corresponding to 330 spatially resolved volume elements in the probe volume. Signal levels are sufficient for the collection of single-laser-pulse images at temperatures of up to approximately 1200 K and shot-averaged images at flame temperatures, demonstrated at 2100 K. The precision of picosecond pure-rotational 1D imaging CARS is assessed by acquiring a series of 100 single-laser-pulse images in a heated flow of N(2) from 410 K-1200 K and evaluating a single volume element for temperature in each image. Accuracy is demonstrated by comparing temperatures from the evaluated averaged spectra to thermocouple readings in the heated flow. Deviations from the thermocouple of &lt;30 K in the evaluated temperature were found at up to 1205 K. Accuracy and single-shot precision are compared to those reported for single-point nanosecond dual-broadband pure-RCARS and nanosecond 1D vibrational CARS.</description><identifier>EISSN: 2155-3165</identifier><identifier>DOI: 10.1364/AO.50.001770</identifier><identifier>PMID: 21509070</identifier><language>eng</language><publisher>United States</publisher><ispartof>Applied optics. Optical technology and biomedical optics, 2011-04, Vol.50 (12), p.1770</ispartof><rights>2011 Optical Society of America</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21509070$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kliewer, Christopher J</creatorcontrib><creatorcontrib>Gao, Yi</creatorcontrib><creatorcontrib>Seeger, Thomas</creatorcontrib><creatorcontrib>Patterson, Brian D</creatorcontrib><creatorcontrib>Farrow, Roger L</creatorcontrib><creatorcontrib>Settersten, Thomas B</creatorcontrib><title>Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy</title><title>Applied optics. Optical technology and biomedical optics</title><addtitle>Appl Opt</addtitle><description>We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotational CARS (RCARS) spectra, corresponding to 330 spatially resolved volume elements in the probe volume. Signal levels are sufficient for the collection of single-laser-pulse images at temperatures of up to approximately 1200 K and shot-averaged images at flame temperatures, demonstrated at 2100 K. The precision of picosecond pure-rotational 1D imaging CARS is assessed by acquiring a series of 100 single-laser-pulse images in a heated flow of N(2) from 410 K-1200 K and evaluating a single volume element for temperature in each image. Accuracy is demonstrated by comparing temperatures from the evaluated averaged spectra to thermocouple readings in the heated flow. Deviations from the thermocouple of &lt;30 K in the evaluated temperature were found at up to 1205 K. Accuracy and single-shot precision are compared to those reported for single-point nanosecond dual-broadband pure-RCARS and nanosecond 1D vibrational CARS.</description><issn>2155-3165</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNo1kEtLAzEUhYMgtlZ3riV_IPUmmZl0lqWoFQrF17rkWaOdZEgyQsEfb-tjcw6Xw_ngHoSuKEwpb6qb-XpawxSACgEnaMxoXRNOm3qEznN-B-B11YozNDoE0IKAMfp6HGQovsjiPy2OwRLjOxuyj0HusO_k1octHvJRe69jtjoGg80gd0SlKI2Sh7MfkiUpHik_PR3fbLKh4CObPJf4YTN-kp0MOPdWlxSzjv3-Ap06ucv28s8n6PXu9mWxJKv1_cNiviKatVCIloJzY6GxoJxh3HLBoNEOTMNcRZWctabmzgBjrGqcaSkowVo3m4FiVFM-Qde_3H5QnTWbPh0eS_vN_wz8G4WJYBg</recordid><startdate>20110420</startdate><enddate>20110420</enddate><creator>Kliewer, Christopher J</creator><creator>Gao, Yi</creator><creator>Seeger, Thomas</creator><creator>Patterson, Brian D</creator><creator>Farrow, Roger L</creator><creator>Settersten, Thomas B</creator><scope>NPM</scope></search><sort><creationdate>20110420</creationdate><title>Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy</title><author>Kliewer, Christopher J ; Gao, Yi ; Seeger, Thomas ; Patterson, Brian D ; Farrow, Roger L ; Settersten, Thomas B</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kliewer, Christopher J</creatorcontrib><creatorcontrib>Gao, Yi</creatorcontrib><creatorcontrib>Seeger, Thomas</creatorcontrib><creatorcontrib>Patterson, Brian D</creatorcontrib><creatorcontrib>Farrow, Roger L</creatorcontrib><creatorcontrib>Settersten, Thomas B</creatorcontrib><collection>PubMed</collection><jtitle>Applied optics. Optical technology and biomedical optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kliewer, Christopher J</au><au>Gao, Yi</au><au>Seeger, Thomas</au><au>Patterson, Brian D</au><au>Farrow, Roger L</au><au>Settersten, Thomas B</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy</atitle><jtitle>Applied optics. Optical technology and biomedical optics</jtitle><addtitle>Appl Opt</addtitle><date>2011-04-20</date><risdate>2011</risdate><volume>50</volume><issue>12</issue><spage>1770</spage><pages>1770-</pages><eissn>2155-3165</eissn><abstract>We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotational CARS (RCARS) spectra, corresponding to 330 spatially resolved volume elements in the probe volume. Signal levels are sufficient for the collection of single-laser-pulse images at temperatures of up to approximately 1200 K and shot-averaged images at flame temperatures, demonstrated at 2100 K. The precision of picosecond pure-rotational 1D imaging CARS is assessed by acquiring a series of 100 single-laser-pulse images in a heated flow of N(2) from 410 K-1200 K and evaluating a single volume element for temperature in each image. Accuracy is demonstrated by comparing temperatures from the evaluated averaged spectra to thermocouple readings in the heated flow. Deviations from the thermocouple of &lt;30 K in the evaluated temperature were found at up to 1205 K. Accuracy and single-shot precision are compared to those reported for single-point nanosecond dual-broadband pure-RCARS and nanosecond 1D vibrational CARS.</abstract><cop>United States</cop><pmid>21509070</pmid><doi>10.1364/AO.50.001770</doi></addata></record>
fulltext fulltext
identifier EISSN: 2155-3165
ispartof Applied optics. Optical technology and biomedical optics, 2011-04, Vol.50 (12), p.1770
issn 2155-3165
language eng
recordid cdi_pubmed_primary_21509070
source OSA Publishing
title Quantitative one-dimensional imaging using picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T00%3A11%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Quantitative%20one-dimensional%20imaging%20using%20picosecond%20dual-broadband%20pure-rotational%20coherent%20anti-Stokes%20Raman%20spectroscopy&rft.jtitle=Applied%20optics.%20Optical%20technology%20and%20biomedical%20optics&rft.au=Kliewer,%20Christopher%20J&rft.date=2011-04-20&rft.volume=50&rft.issue=12&rft.spage=1770&rft.pages=1770-&rft.eissn=2155-3165&rft_id=info:doi/10.1364/AO.50.001770&rft_dat=%3Cpubmed%3E21509070%3C/pubmed%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c290t-ca733de06e0bfd23e37206cf0d62f41ba89d53fd022246fd910b729f880b21c13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/21509070&rfr_iscdi=true