Loading…

Absence of in vitro Procoagulant Activity in Immunoglobulin Preparations due to Activated Coagulation Factors

Background: Immunoglobulin (IG) products, including intravenous (IVIG) or subcutaneous (SCIG) immunoglobulins are considered safe and effective for medical therapy; however, a sudden and unexpected increase in thromboembolic events (TE) after administration of certain batches of IVIG products has be...

Full description

Saved in:
Bibliographic Details
Published in:Transfusion medicine and hemotherapy 2015-11, Vol.42 (6), p.397-402
Main Authors: Oviedo, Adriana E., Bernardi, María E., Guglielmone, Hugo A., Vitali, María S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background: Immunoglobulin (IG) products, including intravenous (IVIG) or subcutaneous (SCIG) immunoglobulins are considered safe and effective for medical therapy; however, a sudden and unexpected increase in thromboembolic events (TE) after administration of certain batches of IVIG products has been attributed to the presence of activated coagulation factors, mainly factor XIa. Our aims were to examine the presence of enduring procoagulant activity during the manufacturing process of IGs, with special focus on monitoring factor XIa, and to evaluate the presence of in vitro procoagulant activity attributed to coagulation factors in different lots of IVIG and SCIG. Methods: Samples of different steps of IG purification, 19 lots of IVIG and 9 of SCIG were analyzed and compared with 1 commercial preparation of IVIG and 2 of SCIG, respectively. Factors II, VII, IX, XI and XIa and non-activated partial thromboplastin time (NAPTT) were assayed. Results: The levels of factors II, VII, IX, X and XI were non-quantifiable once fraction II had been re-dissolved and in all analyzed lots of IVIG and SCIG. The level of factor XIa at that point was under the detection limits of the assay, and NAPTT yielded values greater than the control during the purification process. In SCIG, we detected higher concentrations of factor XIa in the commercial products, which reached values up to 5 times higher than the average amounts found in the 9 batches produced by UNC-Hemoderivados. Factor XIa in commercial IVIG reached levels slightly higher than those of the 19 batches produced by UNC-Hemoderivados. Conclusion: IVIG and SCIG manufactured by UNC-Hemoderivados showed a lack of thrombogenic potential, as demonstrated not only by the laboratory data obtained in this study but also by the absence of any reports of TE registered by the post marketing pharmacovigilance department.
ISSN:1660-3796
1660-3818
DOI:10.1159/000440824