Loading…
Elimination of signals tilting caused by B 0 field inhomogeneity using 2D-lineshape reference deconvolution
An efficient approach for reference deconvolution of two-dimensional spectra aiming at the correction of static field inhomogeneity was established. In comparison to known techniques, a great improvement was achieved using the cross-section along the diagonal of the reference peak instead of its ful...
Saved in:
Published in: | Journal of magnetic resonance (1997) 2017-08, Vol.281, p.229 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | |
container_start_page | 229 |
container_title | Journal of magnetic resonance (1997) |
container_volume | 281 |
creator | Sheberstov, Kirill F Sinitsyn, Dmitry O Cheshkov, Dmitry A Jeannerat, Damien |
description | An efficient approach for reference deconvolution of two-dimensional spectra aiming at the correction of static field inhomogeneity was established. In comparison to known techniques, a great improvement was achieved using the cross-section along the diagonal of the reference peak instead of its full 2D line shape. The method is termed pseudo-2D diagonal deconvolution. The approach developed allows suppressing the two-dimensional peaks tilting caused by the magnetic field inhomogeneity, while keeping the signal-to-noise ratio constant. Long-known method of 2D reference deconvolution (true-2D reference deconvolution) was also applied for comparison. The neutral and resolution-enhancing pseudo-2D deconvolutions were successfully applied for the resolution of complex overlapping multiplets and for measuring small scalar coupling constants. The new algorithm for the elimination of shape distortion of two-dimensional peaks showed to be promising in the perspective of an automated analysis of 2D correlation NMR spectra. |
doi_str_mv | 10.1016/j.jmr.2017.06.005 |
format | article |
fullrecord | <record><control><sourceid>pubmed</sourceid><recordid>TN_cdi_pubmed_primary_28646694</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>28646694</sourcerecordid><originalsourceid>FETCH-LOGICAL-p108t-d0561e1e63f810b844a3c610b15c265178ab196d03e23b78446c4d822d59f57f3</originalsourceid><addsrcrecordid>eNo1j1FLwzAUhYMgbk5_gC-SP9B6b9qk6aPOTYWBL_o80uZmy2zT0rTC_r0b6tM5cD4-OIzdIaQIqB4O6aEdUgFYpKBSAHnB5gilSkBLNWPXMR4AEGUBV2wmtMqVKvM5-1o1vvXBjL4LvHM8-l0wTeSjb0Yfdrw2UyTLqyN_4sCdp8ZyH_Zd2-0okB-PfIpnTjwnjQ8U96YnPpCjgUJN3FLdhe-umc7-G3bpTm66_csF-1yvPpavyeb95W35uEl6BD0mFqRCQlKZ0wiVznOT1erUUNZCSSy0qbBUFjISWVWcdlXnVgthZelk4bIFu__19lPVkt32g2_NcNz-v85-AOMbWRc</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Elimination of signals tilting caused by B 0 field inhomogeneity using 2D-lineshape reference deconvolution</title><source>ScienceDirect Journals</source><creator>Sheberstov, Kirill F ; Sinitsyn, Dmitry O ; Cheshkov, Dmitry A ; Jeannerat, Damien</creator><creatorcontrib>Sheberstov, Kirill F ; Sinitsyn, Dmitry O ; Cheshkov, Dmitry A ; Jeannerat, Damien</creatorcontrib><description>An efficient approach for reference deconvolution of two-dimensional spectra aiming at the correction of static field inhomogeneity was established. In comparison to known techniques, a great improvement was achieved using the cross-section along the diagonal of the reference peak instead of its full 2D line shape. The method is termed pseudo-2D diagonal deconvolution. The approach developed allows suppressing the two-dimensional peaks tilting caused by the magnetic field inhomogeneity, while keeping the signal-to-noise ratio constant. Long-known method of 2D reference deconvolution (true-2D reference deconvolution) was also applied for comparison. The neutral and resolution-enhancing pseudo-2D deconvolutions were successfully applied for the resolution of complex overlapping multiplets and for measuring small scalar coupling constants. The new algorithm for the elimination of shape distortion of two-dimensional peaks showed to be promising in the perspective of an automated analysis of 2D correlation NMR spectra.</description><identifier>EISSN: 1096-0856</identifier><identifier>DOI: 10.1016/j.jmr.2017.06.005</identifier><identifier>PMID: 28646694</identifier><language>eng</language><publisher>United States</publisher><ispartof>Journal of magnetic resonance (1997), 2017-08, Vol.281, p.229</ispartof><rights>Copyright © 2017 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28646694$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sheberstov, Kirill F</creatorcontrib><creatorcontrib>Sinitsyn, Dmitry O</creatorcontrib><creatorcontrib>Cheshkov, Dmitry A</creatorcontrib><creatorcontrib>Jeannerat, Damien</creatorcontrib><title>Elimination of signals tilting caused by B 0 field inhomogeneity using 2D-lineshape reference deconvolution</title><title>Journal of magnetic resonance (1997)</title><addtitle>J Magn Reson</addtitle><description>An efficient approach for reference deconvolution of two-dimensional spectra aiming at the correction of static field inhomogeneity was established. In comparison to known techniques, a great improvement was achieved using the cross-section along the diagonal of the reference peak instead of its full 2D line shape. The method is termed pseudo-2D diagonal deconvolution. The approach developed allows suppressing the two-dimensional peaks tilting caused by the magnetic field inhomogeneity, while keeping the signal-to-noise ratio constant. Long-known method of 2D reference deconvolution (true-2D reference deconvolution) was also applied for comparison. The neutral and resolution-enhancing pseudo-2D deconvolutions were successfully applied for the resolution of complex overlapping multiplets and for measuring small scalar coupling constants. The new algorithm for the elimination of shape distortion of two-dimensional peaks showed to be promising in the perspective of an automated analysis of 2D correlation NMR spectra.</description><issn>1096-0856</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNo1j1FLwzAUhYMgbk5_gC-SP9B6b9qk6aPOTYWBL_o80uZmy2zT0rTC_r0b6tM5cD4-OIzdIaQIqB4O6aEdUgFYpKBSAHnB5gilSkBLNWPXMR4AEGUBV2wmtMqVKvM5-1o1vvXBjL4LvHM8-l0wTeSjb0Yfdrw2UyTLqyN_4sCdp8ZyH_Zd2-0okB-PfIpnTjwnjQ8U96YnPpCjgUJN3FLdhe-umc7-G3bpTm66_csF-1yvPpavyeb95W35uEl6BD0mFqRCQlKZ0wiVznOT1erUUNZCSSy0qbBUFjISWVWcdlXnVgthZelk4bIFu__19lPVkt32g2_NcNz-v85-AOMbWRc</recordid><startdate>201708</startdate><enddate>201708</enddate><creator>Sheberstov, Kirill F</creator><creator>Sinitsyn, Dmitry O</creator><creator>Cheshkov, Dmitry A</creator><creator>Jeannerat, Damien</creator><scope>NPM</scope></search><sort><creationdate>201708</creationdate><title>Elimination of signals tilting caused by B 0 field inhomogeneity using 2D-lineshape reference deconvolution</title><author>Sheberstov, Kirill F ; Sinitsyn, Dmitry O ; Cheshkov, Dmitry A ; Jeannerat, Damien</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p108t-d0561e1e63f810b844a3c610b15c265178ab196d03e23b78446c4d822d59f57f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sheberstov, Kirill F</creatorcontrib><creatorcontrib>Sinitsyn, Dmitry O</creatorcontrib><creatorcontrib>Cheshkov, Dmitry A</creatorcontrib><creatorcontrib>Jeannerat, Damien</creatorcontrib><collection>PubMed</collection><jtitle>Journal of magnetic resonance (1997)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sheberstov, Kirill F</au><au>Sinitsyn, Dmitry O</au><au>Cheshkov, Dmitry A</au><au>Jeannerat, Damien</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Elimination of signals tilting caused by B 0 field inhomogeneity using 2D-lineshape reference deconvolution</atitle><jtitle>Journal of magnetic resonance (1997)</jtitle><addtitle>J Magn Reson</addtitle><date>2017-08</date><risdate>2017</risdate><volume>281</volume><spage>229</spage><pages>229-</pages><eissn>1096-0856</eissn><abstract>An efficient approach for reference deconvolution of two-dimensional spectra aiming at the correction of static field inhomogeneity was established. In comparison to known techniques, a great improvement was achieved using the cross-section along the diagonal of the reference peak instead of its full 2D line shape. The method is termed pseudo-2D diagonal deconvolution. The approach developed allows suppressing the two-dimensional peaks tilting caused by the magnetic field inhomogeneity, while keeping the signal-to-noise ratio constant. Long-known method of 2D reference deconvolution (true-2D reference deconvolution) was also applied for comparison. The neutral and resolution-enhancing pseudo-2D deconvolutions were successfully applied for the resolution of complex overlapping multiplets and for measuring small scalar coupling constants. The new algorithm for the elimination of shape distortion of two-dimensional peaks showed to be promising in the perspective of an automated analysis of 2D correlation NMR spectra.</abstract><cop>United States</cop><pmid>28646694</pmid><doi>10.1016/j.jmr.2017.06.005</doi></addata></record> |
fulltext | fulltext |
identifier | EISSN: 1096-0856 |
ispartof | Journal of magnetic resonance (1997), 2017-08, Vol.281, p.229 |
issn | 1096-0856 |
language | eng |
recordid | cdi_pubmed_primary_28646694 |
source | ScienceDirect Journals |
title | Elimination of signals tilting caused by B 0 field inhomogeneity using 2D-lineshape reference deconvolution |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T10%3A17%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Elimination%20of%20signals%20tilting%20caused%20by%20B%200%20field%20inhomogeneity%20using%202D-lineshape%20reference%20deconvolution&rft.jtitle=Journal%20of%20magnetic%20resonance%20(1997)&rft.au=Sheberstov,%20Kirill%20F&rft.date=2017-08&rft.volume=281&rft.spage=229&rft.pages=229-&rft.eissn=1096-0856&rft_id=info:doi/10.1016/j.jmr.2017.06.005&rft_dat=%3Cpubmed%3E28646694%3C/pubmed%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p108t-d0561e1e63f810b844a3c610b15c265178ab196d03e23b78446c4d822d59f57f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/28646694&rfr_iscdi=true |