Loading…
A Validated Smartphone-based Electrocardiogram Reveals Severe Bradyarrhythmias during Immobilizing Restraint in Mice of Both Sexes and Four Strains
Mouse handling and restraint affect behavior, physiology, and animal welfare, yet little information is available on how various mouse restraint methods affect cardiovascular parameters. We validated the use of a smartphone-based ECG sys- tem in mice by performing simultaneous smartphone and telemet...
Saved in:
Published in: | Journal of the American Association for Laboratory Animal Science 2021-03, Vol.60 (2), p.201-212 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Mouse handling and restraint affect behavior, physiology, and animal welfare, yet little information is available on how various mouse restraint methods affect cardiovascular parameters. We validated the use of a smartphone-based ECG sys- tem in mice by performing simultaneous smartphone
and telemetry ECG recordings in conscious, restrained mice and in anesthetized mice. We observed that mice held in standard immobilizing restraint ("scruffing") experienced severe bradycardia. Mice of both sexes and 4 different strains (BALB/cJ, C57BL/6J, DBA/2J, and FVB/nJ) were restrained
by 3 handlers using 3 different restraint methods: light restraint; 3-finger restraint, which creates a dorsal transverse fold of skin; and the standard immobilizing restraint, which creates a dorsal longitudinal fold of skin that results in a crease on the ventral neck. Regardless of the
handler, immobilizing restraint, but not 3-finger restraint, produced severe bradycardia with irregular rhythm in all 4 strains and both sexes, with an average decrease in heart rate of 31%, or 211 bpm, and a maximal decrease of 79%, or 542 bpm. When evaluated using telemetry, immobilizing
restraint produced severe arrhythmias such as junctional and ventricular escape rhythms, and second- and third-degree atrioventricular block. Sinus pauses were observed for an average of 4 min, but up to 6.8 min after release from immobilizing restraint. Atropine administration to C57BL/6J
mice attenuated immobilizing restraint-induced bradycardia, supporting the hypothesis that pressure on cervical baroreceptors during stretching of the neck skin results in a vagally-mediated reflex bradycardia. Because of these profound cardiovascular effects, we recommend using the light
or 3-finger restraint and avoiding or minimizing the use of immobilization restraint while handling mice. |
---|---|