Estimating the mechanical energy of histotripsy bubble clouds with high frame rate imaging

Mechanical ablation with the focused ultrasound therapy histotripsy relies on the generation and action of bubble clouds. Despite its critical role for ablation, quantitative metrics of bubble activity to gauge treatment outcomes are still lacking. Here, plane wave imaging was used to track the diss...

Full description

Saved in:
Bibliographic Details
Published in:Physics in medicine & biology 2021-08, Vol.66 (16), p.165004
Main Authors: Bader, Kenneth B, Wallach, Emily L, Shekhar, Himanshu, Flores-Guzman, Fernando, Halpern, Howard J, Hernandez, Sonia L
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c467t-904718b3ba7aeb40276acb0075911bb1978dd0e00a32f6f9d6151dcec0ad64cb3
cites cdi_FETCH-LOGICAL-c467t-904718b3ba7aeb40276acb0075911bb1978dd0e00a32f6f9d6151dcec0ad64cb3
container_end_page
container_issue 16
container_start_page 165004
container_title Physics in medicine & biology
container_volume 66
creator Bader, Kenneth B
Wallach, Emily L
Shekhar, Himanshu
Flores-Guzman, Fernando
Halpern, Howard J
Hernandez, Sonia L
description Mechanical ablation with the focused ultrasound therapy histotripsy relies on the generation and action of bubble clouds. Despite its critical role for ablation, quantitative metrics of bubble activity to gauge treatment outcomes are still lacking. Here, plane wave imaging was used to track the dissolution of bubble clouds following initiation with the histotripsy pulse. Information about the rate of change in pixel intensity was coupled with an analytic diffusion model to estimate bubble size. Accuracy of the hybrid measurement/model was assessed by comparing the predicted and measured dissolution time of the bubble cloud. Good agreement was found between predictions and measurements of bubble cloud dissolution times in agarose phantoms and murine subcutaneous SCC VII tumors. The analytic diffusion model was extended to compute the maximum bubble size as well as energy imparted to the tissue due to bubble expansion. Regions within tumors predicted to have undergone strong bubble expansion were collocated with ablation. Further, the dissolution time was found to correlate with acoustic emissions generated by the bubble cloud during histotripsy insonation. Overall, these results indicate a combination of modeling and high frame rate imaging may provide means to quantify mechanical energy imparted to the tissue due to bubble expansion for histotripsy.
doi_str_mv 10.1088/1361-6560/ac155d
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_34271560</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2552985554</sourcerecordid><originalsourceid>FETCH-LOGICAL-c467t-904718b3ba7aeb40276acb0075911bb1978dd0e00a32f6f9d6151dcec0ad64cb3</originalsourceid><addsrcrecordid>eNp9kU1r3DAURUVoSaZJ910VLbOIm_dsS7ZXoYT0AwLdJJtshCTLtoJtOZLcMv8-GiYdWggBgUD36OihS8gnhC8IdX2JBceMMw6XUiNj7RHZHI7ekQ1AgVmTghPyIYRHAMQ6L4_JSVHmFSZmQx5uQrSTjHbuaRwMnYwe5Gy1HKmZje-31HV0sCG66O0StlStSo2G6tGtbaB_bBxS3A-083Iy1MtoaPL1yXdG3ndyDObjy35K7r_d3F3_yG5_ff95_fU20yWvYtZAWWGtCiUraVQJecWlVgAVaxCVwqaq2xYMgCzyjndNy5Fhq40G2fJSq-KUXO29y6omk5I5ejmKxac5_FY4acX_yWwH0bvfAoHX0DSQDOcvBu-eVhOimGzQZhzlbNwaRM5Y3tSMsTKhsEe1dyF40x3eQRC7TsSuALErQOw7SVc-_zvf4cLfEhJwsQesW8SjW_2cvust3_kr-DIpwbnA3WIApVjarngGCHmk-A</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2552985554</pqid></control><display><type>article</type><title>Estimating the mechanical energy of histotripsy bubble clouds with high frame rate imaging</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Bader, Kenneth B ; Wallach, Emily L ; Shekhar, Himanshu ; Flores-Guzman, Fernando ; Halpern, Howard J ; Hernandez, Sonia L</creator><creatorcontrib>Bader, Kenneth B ; Wallach, Emily L ; Shekhar, Himanshu ; Flores-Guzman, Fernando ; Halpern, Howard J ; Hernandez, Sonia L</creatorcontrib><description>Mechanical ablation with the focused ultrasound therapy histotripsy relies on the generation and action of bubble clouds. Despite its critical role for ablation, quantitative metrics of bubble activity to gauge treatment outcomes are still lacking. Here, plane wave imaging was used to track the dissolution of bubble clouds following initiation with the histotripsy pulse. Information about the rate of change in pixel intensity was coupled with an analytic diffusion model to estimate bubble size. Accuracy of the hybrid measurement/model was assessed by comparing the predicted and measured dissolution time of the bubble cloud. Good agreement was found between predictions and measurements of bubble cloud dissolution times in agarose phantoms and murine subcutaneous SCC VII tumors. The analytic diffusion model was extended to compute the maximum bubble size as well as energy imparted to the tissue due to bubble expansion. Regions within tumors predicted to have undergone strong bubble expansion were collocated with ablation. Further, the dissolution time was found to correlate with acoustic emissions generated by the bubble cloud during histotripsy insonation. Overall, these results indicate a combination of modeling and high frame rate imaging may provide means to quantify mechanical energy imparted to the tissue due to bubble expansion for histotripsy.</description><identifier>ISSN: 0031-9155</identifier><identifier>ISSN: 1361-6560</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/ac155d</identifier><identifier>PMID: 34271560</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Acoustics ; Animals ; cavitation ; Diagnostic Imaging ; high frame rate imaging ; High-Intensity Focused Ultrasound Ablation ; histotripsy ; Mice ; Microbubbles ; Phantoms, Imaging</subject><ispartof>Physics in medicine &amp; biology, 2021-08, Vol.66 (16), p.165004</ispartof><rights>2021 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd</rights><rights>Creative Commons Attribution license.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c467t-904718b3ba7aeb40276acb0075911bb1978dd0e00a32f6f9d6151dcec0ad64cb3</citedby><cites>FETCH-LOGICAL-c467t-904718b3ba7aeb40276acb0075911bb1978dd0e00a32f6f9d6151dcec0ad64cb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34271560$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bader, Kenneth B</creatorcontrib><creatorcontrib>Wallach, Emily L</creatorcontrib><creatorcontrib>Shekhar, Himanshu</creatorcontrib><creatorcontrib>Flores-Guzman, Fernando</creatorcontrib><creatorcontrib>Halpern, Howard J</creatorcontrib><creatorcontrib>Hernandez, Sonia L</creatorcontrib><title>Estimating the mechanical energy of histotripsy bubble clouds with high frame rate imaging</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>Mechanical ablation with the focused ultrasound therapy histotripsy relies on the generation and action of bubble clouds. Despite its critical role for ablation, quantitative metrics of bubble activity to gauge treatment outcomes are still lacking. Here, plane wave imaging was used to track the dissolution of bubble clouds following initiation with the histotripsy pulse. Information about the rate of change in pixel intensity was coupled with an analytic diffusion model to estimate bubble size. Accuracy of the hybrid measurement/model was assessed by comparing the predicted and measured dissolution time of the bubble cloud. Good agreement was found between predictions and measurements of bubble cloud dissolution times in agarose phantoms and murine subcutaneous SCC VII tumors. The analytic diffusion model was extended to compute the maximum bubble size as well as energy imparted to the tissue due to bubble expansion. Regions within tumors predicted to have undergone strong bubble expansion were collocated with ablation. Further, the dissolution time was found to correlate with acoustic emissions generated by the bubble cloud during histotripsy insonation. Overall, these results indicate a combination of modeling and high frame rate imaging may provide means to quantify mechanical energy imparted to the tissue due to bubble expansion for histotripsy.</description><subject>Acoustics</subject><subject>Animals</subject><subject>cavitation</subject><subject>Diagnostic Imaging</subject><subject>high frame rate imaging</subject><subject>High-Intensity Focused Ultrasound Ablation</subject><subject>histotripsy</subject><subject>Mice</subject><subject>Microbubbles</subject><subject>Phantoms, Imaging</subject><issn>0031-9155</issn><issn>1361-6560</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9kU1r3DAURUVoSaZJ910VLbOIm_dsS7ZXoYT0AwLdJJtshCTLtoJtOZLcMv8-GiYdWggBgUD36OihS8gnhC8IdX2JBceMMw6XUiNj7RHZHI7ekQ1AgVmTghPyIYRHAMQ6L4_JSVHmFSZmQx5uQrSTjHbuaRwMnYwe5Gy1HKmZje-31HV0sCG66O0StlStSo2G6tGtbaB_bBxS3A-083Iy1MtoaPL1yXdG3ndyDObjy35K7r_d3F3_yG5_ff95_fU20yWvYtZAWWGtCiUraVQJecWlVgAVaxCVwqaq2xYMgCzyjndNy5Fhq40G2fJSq-KUXO29y6omk5I5ejmKxac5_FY4acX_yWwH0bvfAoHX0DSQDOcvBu-eVhOimGzQZhzlbNwaRM5Y3tSMsTKhsEe1dyF40x3eQRC7TsSuALErQOw7SVc-_zvf4cLfEhJwsQesW8SjW_2cvust3_kr-DIpwbnA3WIApVjarngGCHmk-A</recordid><startdate>20210805</startdate><enddate>20210805</enddate><creator>Bader, Kenneth B</creator><creator>Wallach, Emily L</creator><creator>Shekhar, Himanshu</creator><creator>Flores-Guzman, Fernando</creator><creator>Halpern, Howard J</creator><creator>Hernandez, Sonia L</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20210805</creationdate><title>Estimating the mechanical energy of histotripsy bubble clouds with high frame rate imaging</title><author>Bader, Kenneth B ; Wallach, Emily L ; Shekhar, Himanshu ; Flores-Guzman, Fernando ; Halpern, Howard J ; Hernandez, Sonia L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c467t-904718b3ba7aeb40276acb0075911bb1978dd0e00a32f6f9d6151dcec0ad64cb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Acoustics</topic><topic>Animals</topic><topic>cavitation</topic><topic>Diagnostic Imaging</topic><topic>high frame rate imaging</topic><topic>High-Intensity Focused Ultrasound Ablation</topic><topic>histotripsy</topic><topic>Mice</topic><topic>Microbubbles</topic><topic>Phantoms, Imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bader, Kenneth B</creatorcontrib><creatorcontrib>Wallach, Emily L</creatorcontrib><creatorcontrib>Shekhar, Himanshu</creatorcontrib><creatorcontrib>Flores-Guzman, Fernando</creatorcontrib><creatorcontrib>Halpern, Howard J</creatorcontrib><creatorcontrib>Hernandez, Sonia L</creatorcontrib><collection>IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bader, Kenneth B</au><au>Wallach, Emily L</au><au>Shekhar, Himanshu</au><au>Flores-Guzman, Fernando</au><au>Halpern, Howard J</au><au>Hernandez, Sonia L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Estimating the mechanical energy of histotripsy bubble clouds with high frame rate imaging</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2021-08-05</date><risdate>2021</risdate><volume>66</volume><issue>16</issue><spage>165004</spage><pages>165004-</pages><issn>0031-9155</issn><issn>1361-6560</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>Mechanical ablation with the focused ultrasound therapy histotripsy relies on the generation and action of bubble clouds. Despite its critical role for ablation, quantitative metrics of bubble activity to gauge treatment outcomes are still lacking. Here, plane wave imaging was used to track the dissolution of bubble clouds following initiation with the histotripsy pulse. Information about the rate of change in pixel intensity was coupled with an analytic diffusion model to estimate bubble size. Accuracy of the hybrid measurement/model was assessed by comparing the predicted and measured dissolution time of the bubble cloud. Good agreement was found between predictions and measurements of bubble cloud dissolution times in agarose phantoms and murine subcutaneous SCC VII tumors. The analytic diffusion model was extended to compute the maximum bubble size as well as energy imparted to the tissue due to bubble expansion. Regions within tumors predicted to have undergone strong bubble expansion were collocated with ablation. Further, the dissolution time was found to correlate with acoustic emissions generated by the bubble cloud during histotripsy insonation. Overall, these results indicate a combination of modeling and high frame rate imaging may provide means to quantify mechanical energy imparted to the tissue due to bubble expansion for histotripsy.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>34271560</pmid><doi>10.1088/1361-6560/ac155d</doi><tpages>16</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2021-08, Vol.66 (16), p.165004
issn 0031-9155
1361-6560
1361-6560
language eng
recordid cdi_pubmed_primary_34271560
source Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)
subjects Acoustics
Animals
cavitation
Diagnostic Imaging
high frame rate imaging
High-Intensity Focused Ultrasound Ablation
histotripsy
Mice
Microbubbles
Phantoms, Imaging
title Estimating the mechanical energy of histotripsy bubble clouds with high frame rate imaging
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T12%3A05%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Estimating%20the%20mechanical%20energy%20of%20histotripsy%20bubble%20clouds%20with%20high%20frame%20rate%20imaging&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Bader,%20Kenneth%20B&rft.date=2021-08-05&rft.volume=66&rft.issue=16&rft.spage=165004&rft.pages=165004-&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/ac155d&rft_dat=%3Cproquest_pubme%3E2552985554%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c467t-904718b3ba7aeb40276acb0075911bb1978dd0e00a32f6f9d6151dcec0ad64cb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2552985554&rft_id=info:pmid/34271560&rfr_iscdi=true