Loading…

Energy measurement of 241 Am- 9 Be neutrons by tagged neutron time-of-flight

Neutron energy spectrum of a Am- Be source was measured in the energy range of 0.3 to ∼ 6.5 MeV using γ-ray tagged neutron time-of-flight method. BC501A type organic liquid scintillator detector was used at a flight path of 175 cm to detect neutrons with good energy resolution. The de-excitation γ-r...

Full description

Saved in:
Bibliographic Details
Published in:Applied radiation and isotopes 2023-03, Vol.193, p.110655
Main Authors: Shana, F S, Golda, K S, Saneesh, N, Arora, D, Sugathan, P
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Neutron energy spectrum of a Am- Be source was measured in the energy range of 0.3 to ∼ 6.5 MeV using γ-ray tagged neutron time-of-flight method. BC501A type organic liquid scintillator detector was used at a flight path of 175 cm to detect neutrons with good energy resolution. The de-excitation γ-ray emitted in coincidence with neutrons was detected using a fast BaF detector. The measured data has been compared with the ISO 8529-2 standard neutron reference spectrum and found good agreement in the overlapping energy region. Present measurement applied efficiency correction to the data and extended up to 0.3 MeV in the lower energy region compared to earlier reported measurement using similar technique.
ISSN:1872-9800