Loading…
Assessment of the Factors Influencing the Recording Performance of Circumneural Electrodes
The quality of recorded peripheral nerve signals is decisive for their application in therapies. The electroneurogram can be recorded via implantable circumeural electrodes that are wrapped around the peripheral nerve. The shape and amplitude of the signal recorded by the electrode are influenced by...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 4 |
container_issue | |
container_start_page | 1 |
container_title | |
container_volume | 2023 |
creator | Oppelt, V.A. Pfeiffer, F. Pfeifer, R. Schuettler, M. Stieglitz, T. |
description | The quality of recorded peripheral nerve signals is decisive for their application in therapies. The electroneurogram can be recorded via implantable circumeural electrodes that are wrapped around the peripheral nerve. The shape and amplitude of the signal recorded by the electrode are influenced by the design and contact configuration of the electrode. In this paper, the impact of the number of contacts, contact size and electrical insulation to the outside is investigated to predict the single fiber action potential based on the measured impedance data. |
doi_str_mv | 10.1109/EMBC40787.2023.10341201 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>proquest_CHZPO</sourceid><recordid>TN_cdi_pubmed_primary_38083602</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>10341201</ieee_id><sourcerecordid>2902934324</sourcerecordid><originalsourceid>FETCH-LOGICAL-i260t-4d96820afb98541d99184726dd6945affa4e29decc07901f7c7b906f6773a22b3</originalsourceid><addsrcrecordid>eNo9kE1PwzAMhgMSYtPYP0DQI5cO56NNcxzVBpOGQAguXKo0caBSP0bSHvj3dLBxsuz3sSU_hFxTWFAK6nb1eJcLkJlcMGB8QYELyoCekLmSKuMJcCaEpKdkylIlYkhBTMg8hKqEhCciUYyfkwnPIOMpsCl5X4aAITTY9lHnov4To7U2fedDtGldPWBrqvbjd_6CpvN23z2jd51vdGtwv5RX3gxNi4PXdbSq0fS-sxguyJnTdcD5oc7I23r1mj_E26f7Tb7cxhVLoY-FVWnGQLtSZYmgVimaCclSa8cHEu2cFsiURWNAKqBOGlkqSF0qJdeMlXxGbv7u7nz3NWDoi6YKButat9gNoWAKmOJiFDOiVwd0KBu0xc5XjfbfxdHHCFz-ARUi_sdHy_wHjmhuYA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>2902934324</pqid></control><display><type>conference_proceeding</type><title>Assessment of the Factors Influencing the Recording Performance of Circumneural Electrodes</title><source>IEEE Xplore All Conference Series</source><creator>Oppelt, V.A. ; Pfeiffer, F. ; Pfeifer, R. ; Schuettler, M. ; Stieglitz, T.</creator><creatorcontrib>Oppelt, V.A. ; Pfeiffer, F. ; Pfeifer, R. ; Schuettler, M. ; Stieglitz, T.</creatorcontrib><description>The quality of recorded peripheral nerve signals is decisive for their application in therapies. The electroneurogram can be recorded via implantable circumeural electrodes that are wrapped around the peripheral nerve. The shape and amplitude of the signal recorded by the electrode are influenced by the design and contact configuration of the electrode. In this paper, the impact of the number of contacts, contact size and electrical insulation to the outside is investigated to predict the single fiber action potential based on the measured impedance data.</description><identifier>EISSN: 2694-0604</identifier><identifier>EISBN: 9798350324471</identifier><identifier>DOI: 10.1109/EMBC40787.2023.10341201</identifier><identifier>PMID: 38083602</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>Action Potentials - physiology ; Contacts ; Electric Impedance ; Electrodes ; Electrodes, Implanted ; In vivo ; Insulation ; Measurement uncertainty ; Medical treatment ; Peripheral Nerves - physiology ; Shape</subject><ispartof>2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), 2023, Vol.2023, p.1-4</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/10341201$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,27924,27925,54555,54932</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/10341201$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38083602$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Oppelt, V.A.</creatorcontrib><creatorcontrib>Pfeiffer, F.</creatorcontrib><creatorcontrib>Pfeifer, R.</creatorcontrib><creatorcontrib>Schuettler, M.</creatorcontrib><creatorcontrib>Stieglitz, T.</creatorcontrib><title>Assessment of the Factors Influencing the Recording Performance of Circumneural Electrodes</title><title>2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)</title><addtitle>EMBC</addtitle><addtitle>Annu Int Conf IEEE Eng Med Biol Soc</addtitle><description>The quality of recorded peripheral nerve signals is decisive for their application in therapies. The electroneurogram can be recorded via implantable circumeural electrodes that are wrapped around the peripheral nerve. The shape and amplitude of the signal recorded by the electrode are influenced by the design and contact configuration of the electrode. In this paper, the impact of the number of contacts, contact size and electrical insulation to the outside is investigated to predict the single fiber action potential based on the measured impedance data.</description><subject>Action Potentials - physiology</subject><subject>Contacts</subject><subject>Electric Impedance</subject><subject>Electrodes</subject><subject>Electrodes, Implanted</subject><subject>In vivo</subject><subject>Insulation</subject><subject>Measurement uncertainty</subject><subject>Medical treatment</subject><subject>Peripheral Nerves - physiology</subject><subject>Shape</subject><issn>2694-0604</issn><isbn>9798350324471</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2023</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNo9kE1PwzAMhgMSYtPYP0DQI5cO56NNcxzVBpOGQAguXKo0caBSP0bSHvj3dLBxsuz3sSU_hFxTWFAK6nb1eJcLkJlcMGB8QYELyoCekLmSKuMJcCaEpKdkylIlYkhBTMg8hKqEhCciUYyfkwnPIOMpsCl5X4aAITTY9lHnov4To7U2fedDtGldPWBrqvbjd_6CpvN23z2jd51vdGtwv5RX3gxNi4PXdbSq0fS-sxguyJnTdcD5oc7I23r1mj_E26f7Tb7cxhVLoY-FVWnGQLtSZYmgVimaCclSa8cHEu2cFsiURWNAKqBOGlkqSF0qJdeMlXxGbv7u7nz3NWDoi6YKButat9gNoWAKmOJiFDOiVwd0KBu0xc5XjfbfxdHHCFz-ARUi_sdHy_wHjmhuYA</recordid><startdate>20230101</startdate><enddate>20230101</enddate><creator>Oppelt, V.A.</creator><creator>Pfeiffer, F.</creator><creator>Pfeifer, R.</creator><creator>Schuettler, M.</creator><creator>Stieglitz, T.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20230101</creationdate><title>Assessment of the Factors Influencing the Recording Performance of Circumneural Electrodes</title><author>Oppelt, V.A. ; Pfeiffer, F. ; Pfeifer, R. ; Schuettler, M. ; Stieglitz, T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i260t-4d96820afb98541d99184726dd6945affa4e29decc07901f7c7b906f6773a22b3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Action Potentials - physiology</topic><topic>Contacts</topic><topic>Electric Impedance</topic><topic>Electrodes</topic><topic>Electrodes, Implanted</topic><topic>In vivo</topic><topic>Insulation</topic><topic>Measurement uncertainty</topic><topic>Medical treatment</topic><topic>Peripheral Nerves - physiology</topic><topic>Shape</topic><toplevel>online_resources</toplevel><creatorcontrib>Oppelt, V.A.</creatorcontrib><creatorcontrib>Pfeiffer, F.</creatorcontrib><creatorcontrib>Pfeifer, R.</creatorcontrib><creatorcontrib>Schuettler, M.</creatorcontrib><creatorcontrib>Stieglitz, T.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE/IET Electronic Library</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Oppelt, V.A.</au><au>Pfeiffer, F.</au><au>Pfeifer, R.</au><au>Schuettler, M.</au><au>Stieglitz, T.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Assessment of the Factors Influencing the Recording Performance of Circumneural Electrodes</atitle><btitle>2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)</btitle><stitle>EMBC</stitle><addtitle>Annu Int Conf IEEE Eng Med Biol Soc</addtitle><date>2023-01-01</date><risdate>2023</risdate><volume>2023</volume><spage>1</spage><epage>4</epage><pages>1-4</pages><eissn>2694-0604</eissn><eisbn>9798350324471</eisbn><abstract>The quality of recorded peripheral nerve signals is decisive for their application in therapies. The electroneurogram can be recorded via implantable circumeural electrodes that are wrapped around the peripheral nerve. The shape and amplitude of the signal recorded by the electrode are influenced by the design and contact configuration of the electrode. In this paper, the impact of the number of contacts, contact size and electrical insulation to the outside is investigated to predict the single fiber action potential based on the measured impedance data.</abstract><cop>United States</cop><pub>IEEE</pub><pmid>38083602</pmid><doi>10.1109/EMBC40787.2023.10341201</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | EISSN: 2694-0604 |
ispartof | 2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), 2023, Vol.2023, p.1-4 |
issn | 2694-0604 |
language | eng |
recordid | cdi_pubmed_primary_38083602 |
source | IEEE Xplore All Conference Series |
subjects | Action Potentials - physiology Contacts Electric Impedance Electrodes Electrodes, Implanted In vivo Insulation Measurement uncertainty Medical treatment Peripheral Nerves - physiology Shape |
title | Assessment of the Factors Influencing the Recording Performance of Circumneural Electrodes |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T16%3A31%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Assessment%20of%20the%20Factors%20Influencing%20the%20Recording%20Performance%20of%20Circumneural%20Electrodes&rft.btitle=2023%2045th%20Annual%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20&%20Biology%20Society%20(EMBC)&rft.au=Oppelt,%20V.A.&rft.date=2023-01-01&rft.volume=2023&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.eissn=2694-0604&rft_id=info:doi/10.1109/EMBC40787.2023.10341201&rft.eisbn=9798350324471&rft_dat=%3Cproquest_CHZPO%3E2902934324%3C/proquest_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i260t-4d96820afb98541d99184726dd6945affa4e29decc07901f7c7b906f6773a22b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2902934324&rft_id=info:pmid/38083602&rft_ieee_id=10341201&rfr_iscdi=true |