Loading…

Rapid and simple determination of clenbuterol residues in retina by high-performance liquid chromatography with ultraviolet detection

A new method for the determination of clenbuterol by reversed-phase HPLC with UV detection has been developed. Clenbuterol was eluted on a C 8 column(250 × 4.6mm I.D.), using an isocratic eluent consisting of anacetonitrile-0.02 M phosphate buffer (25:75, v/v) adjusted to pH 2.8 with phosphoric acid...

Full description

Saved in:
Bibliographic Details
Published in:Journal of chromatography. B, Biomedical applications Biomedical applications, 1996-02, Vol.677 (1), p.167-171
Main Authors: Gigosos, Pilar Gonza´lez, Ferna´ndez, Teresa Ferna´ndez, Mari´z, Oliva Cadahi´a, Fente Sampayo, Cristina A., Abui´n, Carlos Franco, Sa´ez, Alberto Cepeda
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c386t-cb87f47bd2f128a90c3e3c0f34d2d90e04e6d3f40734ffe39ec35b21ea0151443
cites cdi_FETCH-LOGICAL-c386t-cb87f47bd2f128a90c3e3c0f34d2d90e04e6d3f40734ffe39ec35b21ea0151443
container_end_page 171
container_issue 1
container_start_page 167
container_title Journal of chromatography. B, Biomedical applications
container_volume 677
creator Gigosos, Pilar Gonza´lez
Ferna´ndez, Teresa Ferna´ndez
Mari´z, Oliva Cadahi´a
Fente Sampayo, Cristina A.
Abui´n, Carlos Franco
Sa´ez, Alberto Cepeda
description A new method for the determination of clenbuterol by reversed-phase HPLC with UV detection has been developed. Clenbuterol was eluted on a C 8 column(250 × 4.6mm I.D.), using an isocratic eluent consisting of anacetonitrile-0.02 M phosphate buffer (25:75, v/v) adjusted to pH 2.8 with phosphoric acid. The method was linear from 2.5 to 50 ng injected. The detection limit was established to be 0.5 ng (signal/background ratio: 3), and the quantification limit was 2.5 ng. With the proposed method, we got a simple and rapid detection of clenbuterol in the retina, part of the animal where the biggest amount of clenbuterol is accumulated and where it remains for the longest time after any treatment.
doi_str_mv 10.1016/0378-4347(95)00476-9
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_pubmed_primary_8925091</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0378434795004769</els_id><sourcerecordid>0378434795004769</sourcerecordid><originalsourceid>FETCH-LOGICAL-c386t-cb87f47bd2f128a90c3e3c0f34d2d90e04e6d3f40734ffe39ec35b21ea0151443</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhnNQ_Fj9Bwo56qGaNOm2uQiy-AULgug5pMnERtqmJu3K_gD_t1lX9uhphpl55515EDqj5IoSOr8mrKwyznh5IYpLQng5z8QeOtqVD9FxjB-EME7y_AAdVCIviKBH6PtFDc5g1RscXTe0gA2MEDrXq9H5HnuLdQt9PaWib3GA6MwEEbs-5WOawvUaN-69yQYI1odO9Rpw6z6ntFU3wXdq9O9BDc0af7mxwVM7BrVyvoXx10pvbE7QvlVthNO_OENv93evi8ds-fzwtLhdZppV8zHTdVVaXtYmtzSvlCCaAdPEMm5yIwgQDnPDLCcl49YCE6BZUecUFKEF5ZzNEN_u1cHHGMDKIbhOhbWkRG5Ayg0xuSEmRSF_QUqRZOdb2TDVHZid6I9i6t9s-5BuXzkIMmoHCYRxIT0ojXf_G_wAUG2Iew</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Rapid and simple determination of clenbuterol residues in retina by high-performance liquid chromatography with ultraviolet detection</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Gigosos, Pilar Gonza´lez ; Ferna´ndez, Teresa Ferna´ndez ; Mari´z, Oliva Cadahi´a ; Fente Sampayo, Cristina A. ; Abui´n, Carlos Franco ; Sa´ez, Alberto Cepeda</creator><creatorcontrib>Gigosos, Pilar Gonza´lez ; Ferna´ndez, Teresa Ferna´ndez ; Mari´z, Oliva Cadahi´a ; Fente Sampayo, Cristina A. ; Abui´n, Carlos Franco ; Sa´ez, Alberto Cepeda</creatorcontrib><description>A new method for the determination of clenbuterol by reversed-phase HPLC with UV detection has been developed. Clenbuterol was eluted on a C 8 column(250 × 4.6mm I.D.), using an isocratic eluent consisting of anacetonitrile-0.02 M phosphate buffer (25:75, v/v) adjusted to pH 2.8 with phosphoric acid. The method was linear from 2.5 to 50 ng injected. The detection limit was established to be 0.5 ng (signal/background ratio: 3), and the quantification limit was 2.5 ng. With the proposed method, we got a simple and rapid detection of clenbuterol in the retina, part of the animal where the biggest amount of clenbuterol is accumulated and where it remains for the longest time after any treatment.</description><identifier>ISSN: 0378-4347</identifier><identifier>ISSN: 1572-6495</identifier><identifier>DOI: 10.1016/0378-4347(95)00476-9</identifier><identifier>PMID: 8925091</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Animals ; Aqueous Humor - chemistry ; Calibration ; Chromatography, High Pressure Liquid ; Clenbuterol ; Clenbuterol - chemistry ; Drug Residues - chemistry ; Rats ; Retina - chemistry ; Spectrophotometry, Ultraviolet ; Ultracentrifugation</subject><ispartof>Journal of chromatography. B, Biomedical applications, 1996-02, Vol.677 (1), p.167-171</ispartof><rights>1996 Elsevier Science B.V. All rights reserved</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c386t-cb87f47bd2f128a90c3e3c0f34d2d90e04e6d3f40734ffe39ec35b21ea0151443</citedby><cites>FETCH-LOGICAL-c386t-cb87f47bd2f128a90c3e3c0f34d2d90e04e6d3f40734ffe39ec35b21ea0151443</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8925091$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gigosos, Pilar Gonza´lez</creatorcontrib><creatorcontrib>Ferna´ndez, Teresa Ferna´ndez</creatorcontrib><creatorcontrib>Mari´z, Oliva Cadahi´a</creatorcontrib><creatorcontrib>Fente Sampayo, Cristina A.</creatorcontrib><creatorcontrib>Abui´n, Carlos Franco</creatorcontrib><creatorcontrib>Sa´ez, Alberto Cepeda</creatorcontrib><title>Rapid and simple determination of clenbuterol residues in retina by high-performance liquid chromatography with ultraviolet detection</title><title>Journal of chromatography. B, Biomedical applications</title><addtitle>J Chromatogr B Biomed Appl</addtitle><description>A new method for the determination of clenbuterol by reversed-phase HPLC with UV detection has been developed. Clenbuterol was eluted on a C 8 column(250 × 4.6mm I.D.), using an isocratic eluent consisting of anacetonitrile-0.02 M phosphate buffer (25:75, v/v) adjusted to pH 2.8 with phosphoric acid. The method was linear from 2.5 to 50 ng injected. The detection limit was established to be 0.5 ng (signal/background ratio: 3), and the quantification limit was 2.5 ng. With the proposed method, we got a simple and rapid detection of clenbuterol in the retina, part of the animal where the biggest amount of clenbuterol is accumulated and where it remains for the longest time after any treatment.</description><subject>Animals</subject><subject>Aqueous Humor - chemistry</subject><subject>Calibration</subject><subject>Chromatography, High Pressure Liquid</subject><subject>Clenbuterol</subject><subject>Clenbuterol - chemistry</subject><subject>Drug Residues - chemistry</subject><subject>Rats</subject><subject>Retina - chemistry</subject><subject>Spectrophotometry, Ultraviolet</subject><subject>Ultracentrifugation</subject><issn>0378-4347</issn><issn>1572-6495</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhnNQ_Fj9Bwo56qGaNOm2uQiy-AULgug5pMnERtqmJu3K_gD_t1lX9uhphpl55515EDqj5IoSOr8mrKwyznh5IYpLQng5z8QeOtqVD9FxjB-EME7y_AAdVCIviKBH6PtFDc5g1RscXTe0gA2MEDrXq9H5HnuLdQt9PaWib3GA6MwEEbs-5WOawvUaN-69yQYI1odO9Rpw6z6ntFU3wXdq9O9BDc0af7mxwVM7BrVyvoXx10pvbE7QvlVthNO_OENv93evi8ds-fzwtLhdZppV8zHTdVVaXtYmtzSvlCCaAdPEMm5yIwgQDnPDLCcl49YCE6BZUecUFKEF5ZzNEN_u1cHHGMDKIbhOhbWkRG5Ayg0xuSEmRSF_QUqRZOdb2TDVHZid6I9i6t9s-5BuXzkIMmoHCYRxIT0ojXf_G_wAUG2Iew</recordid><startdate>19960223</startdate><enddate>19960223</enddate><creator>Gigosos, Pilar Gonza´lez</creator><creator>Ferna´ndez, Teresa Ferna´ndez</creator><creator>Mari´z, Oliva Cadahi´a</creator><creator>Fente Sampayo, Cristina A.</creator><creator>Abui´n, Carlos Franco</creator><creator>Sa´ez, Alberto Cepeda</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19960223</creationdate><title>Rapid and simple determination of clenbuterol residues in retina by high-performance liquid chromatography with ultraviolet detection</title><author>Gigosos, Pilar Gonza´lez ; Ferna´ndez, Teresa Ferna´ndez ; Mari´z, Oliva Cadahi´a ; Fente Sampayo, Cristina A. ; Abui´n, Carlos Franco ; Sa´ez, Alberto Cepeda</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c386t-cb87f47bd2f128a90c3e3c0f34d2d90e04e6d3f40734ffe39ec35b21ea0151443</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Animals</topic><topic>Aqueous Humor - chemistry</topic><topic>Calibration</topic><topic>Chromatography, High Pressure Liquid</topic><topic>Clenbuterol</topic><topic>Clenbuterol - chemistry</topic><topic>Drug Residues - chemistry</topic><topic>Rats</topic><topic>Retina - chemistry</topic><topic>Spectrophotometry, Ultraviolet</topic><topic>Ultracentrifugation</topic><toplevel>online_resources</toplevel><creatorcontrib>Gigosos, Pilar Gonza´lez</creatorcontrib><creatorcontrib>Ferna´ndez, Teresa Ferna´ndez</creatorcontrib><creatorcontrib>Mari´z, Oliva Cadahi´a</creatorcontrib><creatorcontrib>Fente Sampayo, Cristina A.</creatorcontrib><creatorcontrib>Abui´n, Carlos Franco</creatorcontrib><creatorcontrib>Sa´ez, Alberto Cepeda</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>Journal of chromatography. B, Biomedical applications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gigosos, Pilar Gonza´lez</au><au>Ferna´ndez, Teresa Ferna´ndez</au><au>Mari´z, Oliva Cadahi´a</au><au>Fente Sampayo, Cristina A.</au><au>Abui´n, Carlos Franco</au><au>Sa´ez, Alberto Cepeda</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid and simple determination of clenbuterol residues in retina by high-performance liquid chromatography with ultraviolet detection</atitle><jtitle>Journal of chromatography. B, Biomedical applications</jtitle><addtitle>J Chromatogr B Biomed Appl</addtitle><date>1996-02-23</date><risdate>1996</risdate><volume>677</volume><issue>1</issue><spage>167</spage><epage>171</epage><pages>167-171</pages><issn>0378-4347</issn><issn>1572-6495</issn><abstract>A new method for the determination of clenbuterol by reversed-phase HPLC with UV detection has been developed. Clenbuterol was eluted on a C 8 column(250 × 4.6mm I.D.), using an isocratic eluent consisting of anacetonitrile-0.02 M phosphate buffer (25:75, v/v) adjusted to pH 2.8 with phosphoric acid. The method was linear from 2.5 to 50 ng injected. The detection limit was established to be 0.5 ng (signal/background ratio: 3), and the quantification limit was 2.5 ng. With the proposed method, we got a simple and rapid detection of clenbuterol in the retina, part of the animal where the biggest amount of clenbuterol is accumulated and where it remains for the longest time after any treatment.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>8925091</pmid><doi>10.1016/0378-4347(95)00476-9</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-4347
ispartof Journal of chromatography. B, Biomedical applications, 1996-02, Vol.677 (1), p.167-171
issn 0378-4347
1572-6495
language eng
recordid cdi_pubmed_primary_8925091
source ScienceDirect Freedom Collection 2022-2024
subjects Animals
Aqueous Humor - chemistry
Calibration
Chromatography, High Pressure Liquid
Clenbuterol
Clenbuterol - chemistry
Drug Residues - chemistry
Rats
Retina - chemistry
Spectrophotometry, Ultraviolet
Ultracentrifugation
title Rapid and simple determination of clenbuterol residues in retina by high-performance liquid chromatography with ultraviolet detection
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T08%3A14%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20and%20simple%20determination%20of%20clenbuterol%20residues%20in%20retina%20by%20high-performance%20liquid%20chromatography%20with%20ultraviolet%20detection&rft.jtitle=Journal%20of%20chromatography.%20B,%20Biomedical%20applications&rft.au=Gigosos,%20Pilar%20Gonza%C2%B4lez&rft.date=1996-02-23&rft.volume=677&rft.issue=1&rft.spage=167&rft.epage=171&rft.pages=167-171&rft.issn=0378-4347&rft_id=info:doi/10.1016/0378-4347(95)00476-9&rft_dat=%3Celsevier_cross%3E0378434795004769%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c386t-cb87f47bd2f128a90c3e3c0f34d2d90e04e6d3f40734ffe39ec35b21ea0151443%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/8925091&rfr_iscdi=true