Loading…

Synchronization of timepieces to the atomic clock in an urban emergency medical services system

Erroneous time documentation of emergency treatment caused by the variation in the accuracy of timepieces has profound medical, medicolegal, and research consequences. The purpose of this study was to confirm the variation of critical timepiece settings in an urban emergency care system noted in pre...

Full description

Saved in:
Bibliographic Details
Published in:Annals of emergency medicine 1998-04, Vol.31 (4), p.483
Main Authors: Ornato, J P, Doctor, M L, Harbour, L F, Peberdy, M A, Overton, J, Racht, E M, Zauhar, W G, Smith, A P, Ryan, K A
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 4
container_start_page 483
container_title Annals of emergency medicine
container_volume 31
creator Ornato, J P
Doctor, M L
Harbour, L F
Peberdy, M A
Overton, J
Racht, E M
Zauhar, W G
Smith, A P
Ryan, K A
description Erroneous time documentation of emergency treatment caused by the variation in the accuracy of timepieces has profound medical, medicolegal, and research consequences. The purpose of this study was to confirm the variation of critical timepiece settings in an urban emergency care system noted in previous studies and to implement and monitor the results of a prospective program to improve time synchronization. Timepieces (n = 393) used by firefighters, paramedics, and emergency physicians and nurses were randomly sampled immediately before and at two time intervals (1 and 4 months) after attempted synchronization to the US atomic clock standard. The setting on each timepiece was compared with the atomic clock. From the data, a mathematical simulation estimated the number of time-related documentation errors that would occur in 2,500 simulated cardiac arrest cases using timepieces with accuracy similar to those found in the EMS system before and after attempted synchronization. Before attempted synchronization, the timepieces had a mean error of 2.0 (95% confidence interval 1.8 to 2.3) minutes. One month after attempted synchronization, the mean error decreased significantly to .9(.8 to 1.1) minute. However, it increased to 1.7 (1.5 to 1.9) minutes within 4 months. Mathematical simulation before attempted synchronization predicted that 93% of cardiac arrest cases would contain a documentation error of 2 minutes or more and that 41% of cases would contain a documentation error of 5 minutes or more. Attempted synchronization cut the 2-minute documentation error rate in half and reduced the 5-minute documentation error rate by three fourths. However, the error rates were predicted to return to baseline 4 months after attempted synchronization. Emergency medical timepieces are often inaccurate, making it difficult to reconstruct events for medical, medicolegal, or research purposes. Community synchronization of timepieces to the atomic clock can reduce the problem significantly, but the effects of a one-time attempted synchronization event are short-lived.
format article
fullrecord <record><control><sourceid>pubmed</sourceid><recordid>TN_cdi_pubmed_primary_9546018</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>9546018</sourcerecordid><originalsourceid>FETCH-pubmed_primary_95460183</originalsourceid><addsrcrecordid>eNqFjr0KwjAURjMotf48gnBfoJBqLHYWxV33EuOtvdokJUmF-PRW6O7yneFw4JuwlOdlkfFCiBmbe__knJdikycsKXei4Pk-ZdUlGtU4a-gjA1kDtoZAGjtChR6ChdAgyGA1KVCtVS8gA9JA727Dokb3QKMiaLyTki14dG_6pT76gHrJprVsPa5GLtj6dLwezlnX34ak6hxp6WI1Htr-81-AM0Hw</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Synchronization of timepieces to the atomic clock in an urban emergency medical services system</title><source>ScienceDirect Freedom Collection</source><creator>Ornato, J P ; Doctor, M L ; Harbour, L F ; Peberdy, M A ; Overton, J ; Racht, E M ; Zauhar, W G ; Smith, A P ; Ryan, K A</creator><creatorcontrib>Ornato, J P ; Doctor, M L ; Harbour, L F ; Peberdy, M A ; Overton, J ; Racht, E M ; Zauhar, W G ; Smith, A P ; Ryan, K A</creatorcontrib><description>Erroneous time documentation of emergency treatment caused by the variation in the accuracy of timepieces has profound medical, medicolegal, and research consequences. The purpose of this study was to confirm the variation of critical timepiece settings in an urban emergency care system noted in previous studies and to implement and monitor the results of a prospective program to improve time synchronization. Timepieces (n = 393) used by firefighters, paramedics, and emergency physicians and nurses were randomly sampled immediately before and at two time intervals (1 and 4 months) after attempted synchronization to the US atomic clock standard. The setting on each timepiece was compared with the atomic clock. From the data, a mathematical simulation estimated the number of time-related documentation errors that would occur in 2,500 simulated cardiac arrest cases using timepieces with accuracy similar to those found in the EMS system before and after attempted synchronization. Before attempted synchronization, the timepieces had a mean error of 2.0 (95% confidence interval 1.8 to 2.3) minutes. One month after attempted synchronization, the mean error decreased significantly to .9(.8 to 1.1) minute. However, it increased to 1.7 (1.5 to 1.9) minutes within 4 months. Mathematical simulation before attempted synchronization predicted that 93% of cardiac arrest cases would contain a documentation error of 2 minutes or more and that 41% of cases would contain a documentation error of 5 minutes or more. Attempted synchronization cut the 2-minute documentation error rate in half and reduced the 5-minute documentation error rate by three fourths. However, the error rates were predicted to return to baseline 4 months after attempted synchronization. Emergency medical timepieces are often inaccurate, making it difficult to reconstruct events for medical, medicolegal, or research purposes. Community synchronization of timepieces to the atomic clock can reduce the problem significantly, but the effects of a one-time attempted synchronization event are short-lived.</description><identifier>ISSN: 0196-0644</identifier><identifier>PMID: 9546018</identifier><language>eng</language><publisher>United States</publisher><subject>Death Certificates ; Documentation - statistics &amp; numerical data ; Emergency Service, Hospital - statistics &amp; numerical data ; Heart Arrest - mortality ; Hospitals, Urban - statistics &amp; numerical data ; Humans ; Models, Theoretical ; Patient Care Team - statistics &amp; numerical data ; Reference Standards ; Reproducibility of Results ; Time ; Time Management ; Virginia</subject><ispartof>Annals of emergency medicine, 1998-04, Vol.31 (4), p.483</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9546018$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ornato, J P</creatorcontrib><creatorcontrib>Doctor, M L</creatorcontrib><creatorcontrib>Harbour, L F</creatorcontrib><creatorcontrib>Peberdy, M A</creatorcontrib><creatorcontrib>Overton, J</creatorcontrib><creatorcontrib>Racht, E M</creatorcontrib><creatorcontrib>Zauhar, W G</creatorcontrib><creatorcontrib>Smith, A P</creatorcontrib><creatorcontrib>Ryan, K A</creatorcontrib><title>Synchronization of timepieces to the atomic clock in an urban emergency medical services system</title><title>Annals of emergency medicine</title><addtitle>Ann Emerg Med</addtitle><description>Erroneous time documentation of emergency treatment caused by the variation in the accuracy of timepieces has profound medical, medicolegal, and research consequences. The purpose of this study was to confirm the variation of critical timepiece settings in an urban emergency care system noted in previous studies and to implement and monitor the results of a prospective program to improve time synchronization. Timepieces (n = 393) used by firefighters, paramedics, and emergency physicians and nurses were randomly sampled immediately before and at two time intervals (1 and 4 months) after attempted synchronization to the US atomic clock standard. The setting on each timepiece was compared with the atomic clock. From the data, a mathematical simulation estimated the number of time-related documentation errors that would occur in 2,500 simulated cardiac arrest cases using timepieces with accuracy similar to those found in the EMS system before and after attempted synchronization. Before attempted synchronization, the timepieces had a mean error of 2.0 (95% confidence interval 1.8 to 2.3) minutes. One month after attempted synchronization, the mean error decreased significantly to .9(.8 to 1.1) minute. However, it increased to 1.7 (1.5 to 1.9) minutes within 4 months. Mathematical simulation before attempted synchronization predicted that 93% of cardiac arrest cases would contain a documentation error of 2 minutes or more and that 41% of cases would contain a documentation error of 5 minutes or more. Attempted synchronization cut the 2-minute documentation error rate in half and reduced the 5-minute documentation error rate by three fourths. However, the error rates were predicted to return to baseline 4 months after attempted synchronization. Emergency medical timepieces are often inaccurate, making it difficult to reconstruct events for medical, medicolegal, or research purposes. Community synchronization of timepieces to the atomic clock can reduce the problem significantly, but the effects of a one-time attempted synchronization event are short-lived.</description><subject>Death Certificates</subject><subject>Documentation - statistics &amp; numerical data</subject><subject>Emergency Service, Hospital - statistics &amp; numerical data</subject><subject>Heart Arrest - mortality</subject><subject>Hospitals, Urban - statistics &amp; numerical data</subject><subject>Humans</subject><subject>Models, Theoretical</subject><subject>Patient Care Team - statistics &amp; numerical data</subject><subject>Reference Standards</subject><subject>Reproducibility of Results</subject><subject>Time</subject><subject>Time Management</subject><subject>Virginia</subject><issn>0196-0644</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFjr0KwjAURjMotf48gnBfoJBqLHYWxV33EuOtvdokJUmF-PRW6O7yneFw4JuwlOdlkfFCiBmbe__knJdikycsKXei4Pk-ZdUlGtU4a-gjA1kDtoZAGjtChR6ChdAgyGA1KVCtVS8gA9JA727Dokb3QKMiaLyTki14dG_6pT76gHrJprVsPa5GLtj6dLwezlnX34ak6hxp6WI1Htr-81-AM0Hw</recordid><startdate>199804</startdate><enddate>199804</enddate><creator>Ornato, J P</creator><creator>Doctor, M L</creator><creator>Harbour, L F</creator><creator>Peberdy, M A</creator><creator>Overton, J</creator><creator>Racht, E M</creator><creator>Zauhar, W G</creator><creator>Smith, A P</creator><creator>Ryan, K A</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope></search><sort><creationdate>199804</creationdate><title>Synchronization of timepieces to the atomic clock in an urban emergency medical services system</title><author>Ornato, J P ; Doctor, M L ; Harbour, L F ; Peberdy, M A ; Overton, J ; Racht, E M ; Zauhar, W G ; Smith, A P ; Ryan, K A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-pubmed_primary_95460183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Death Certificates</topic><topic>Documentation - statistics &amp; numerical data</topic><topic>Emergency Service, Hospital - statistics &amp; numerical data</topic><topic>Heart Arrest - mortality</topic><topic>Hospitals, Urban - statistics &amp; numerical data</topic><topic>Humans</topic><topic>Models, Theoretical</topic><topic>Patient Care Team - statistics &amp; numerical data</topic><topic>Reference Standards</topic><topic>Reproducibility of Results</topic><topic>Time</topic><topic>Time Management</topic><topic>Virginia</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ornato, J P</creatorcontrib><creatorcontrib>Doctor, M L</creatorcontrib><creatorcontrib>Harbour, L F</creatorcontrib><creatorcontrib>Peberdy, M A</creatorcontrib><creatorcontrib>Overton, J</creatorcontrib><creatorcontrib>Racht, E M</creatorcontrib><creatorcontrib>Zauhar, W G</creatorcontrib><creatorcontrib>Smith, A P</creatorcontrib><creatorcontrib>Ryan, K A</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><jtitle>Annals of emergency medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ornato, J P</au><au>Doctor, M L</au><au>Harbour, L F</au><au>Peberdy, M A</au><au>Overton, J</au><au>Racht, E M</au><au>Zauhar, W G</au><au>Smith, A P</au><au>Ryan, K A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Synchronization of timepieces to the atomic clock in an urban emergency medical services system</atitle><jtitle>Annals of emergency medicine</jtitle><addtitle>Ann Emerg Med</addtitle><date>1998-04</date><risdate>1998</risdate><volume>31</volume><issue>4</issue><spage>483</spage><pages>483-</pages><issn>0196-0644</issn><abstract>Erroneous time documentation of emergency treatment caused by the variation in the accuracy of timepieces has profound medical, medicolegal, and research consequences. The purpose of this study was to confirm the variation of critical timepiece settings in an urban emergency care system noted in previous studies and to implement and monitor the results of a prospective program to improve time synchronization. Timepieces (n = 393) used by firefighters, paramedics, and emergency physicians and nurses were randomly sampled immediately before and at two time intervals (1 and 4 months) after attempted synchronization to the US atomic clock standard. The setting on each timepiece was compared with the atomic clock. From the data, a mathematical simulation estimated the number of time-related documentation errors that would occur in 2,500 simulated cardiac arrest cases using timepieces with accuracy similar to those found in the EMS system before and after attempted synchronization. Before attempted synchronization, the timepieces had a mean error of 2.0 (95% confidence interval 1.8 to 2.3) minutes. One month after attempted synchronization, the mean error decreased significantly to .9(.8 to 1.1) minute. However, it increased to 1.7 (1.5 to 1.9) minutes within 4 months. Mathematical simulation before attempted synchronization predicted that 93% of cardiac arrest cases would contain a documentation error of 2 minutes or more and that 41% of cases would contain a documentation error of 5 minutes or more. Attempted synchronization cut the 2-minute documentation error rate in half and reduced the 5-minute documentation error rate by three fourths. However, the error rates were predicted to return to baseline 4 months after attempted synchronization. Emergency medical timepieces are often inaccurate, making it difficult to reconstruct events for medical, medicolegal, or research purposes. Community synchronization of timepieces to the atomic clock can reduce the problem significantly, but the effects of a one-time attempted synchronization event are short-lived.</abstract><cop>United States</cop><pmid>9546018</pmid></addata></record>
fulltext fulltext
identifier ISSN: 0196-0644
ispartof Annals of emergency medicine, 1998-04, Vol.31 (4), p.483
issn 0196-0644
language eng
recordid cdi_pubmed_primary_9546018
source ScienceDirect Freedom Collection
subjects Death Certificates
Documentation - statistics & numerical data
Emergency Service, Hospital - statistics & numerical data
Heart Arrest - mortality
Hospitals, Urban - statistics & numerical data
Humans
Models, Theoretical
Patient Care Team - statistics & numerical data
Reference Standards
Reproducibility of Results
Time
Time Management
Virginia
title Synchronization of timepieces to the atomic clock in an urban emergency medical services system
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T17%3A22%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Synchronization%20of%20timepieces%20to%20the%20atomic%20clock%20in%20an%20urban%20emergency%20medical%20services%20system&rft.jtitle=Annals%20of%20emergency%20medicine&rft.au=Ornato,%20J%20P&rft.date=1998-04&rft.volume=31&rft.issue=4&rft.spage=483&rft.pages=483-&rft.issn=0196-0644&rft_id=info:doi/&rft_dat=%3Cpubmed%3E9546018%3C/pubmed%3E%3Cgrp_id%3Ecdi_FETCH-pubmed_primary_95460183%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/9546018&rfr_iscdi=true