Loading…
Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects
Twenty nine patients (aged from three months to 37 years) with confirmed or suspected ventricular septal defects were studied separately by three examiners who used colour flow mapping and imaging, or continuous wave Doppler and imaging, or a combined reference examination. Colour flow mapping ident...
Saved in:
Published in: | British Heart Journal 1991-04, Vol.65 (4), p.201-203 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-b477t-1788155dbdc5137b940f85395b02f9780abf870b325a9c84aa89ad240e8ec4fb3 |
---|---|
cites | cdi_FETCH-LOGICAL-b477t-1788155dbdc5137b940f85395b02f9780abf870b325a9c84aa89ad240e8ec4fb3 |
container_end_page | 203 |
container_issue | 4 |
container_start_page | 201 |
container_title | British Heart Journal |
container_volume | 65 |
creator | Linker, D T Rossvoll, O Chapman, J V Angelsen, B A |
description | Twenty nine patients (aged from three months to 37 years) with confirmed or suspected ventricular septal defects were studied separately by three examiners who used colour flow mapping and imaging, or continuous wave Doppler and imaging, or a combined reference examination. Colour flow mapping identified 19 of the 25 patients with a ventricular septal defect, continuous wave Doppler echocardiography identified 18, and the combined reference examination identified 24. Two of four patients without ventricular septal defect had a false positive result with colour flow mapping and none had a false positive result with continuous wave Doppler examination. During the reference examination continuous wave Doppler identified 24 patients with ventricular septal defects and colour flow mapping identified 23. In two patients a second ventricular septal defect was found by colour flow mapping, and confirmed by continuous wave Doppler. There was no significant difference in time to diagnosis between the two techniques. Colour flow mapping aids identification of multiple ventricular septal defects but is not faster and has lower specificity than continuous wave Doppler. A combination of the two techniques gave the highest sensitivity and specificity. |
doi_str_mv | 10.1136/hrt.65.4.201 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1024580</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80554375</sourcerecordid><originalsourceid>FETCH-LOGICAL-b477t-1788155dbdc5137b940f85395b02f9780abf870b325a9c84aa89ad240e8ec4fb3</originalsourceid><addsrcrecordid>eNp9kc2O0zAUhS0EGsrAji2SJSTYkHKd2LGzGQkVBpAKSHQYsbOcxJm6JHawnZZ5BZ4aV63Kz4KVbZ3Px8f3IPSYwJyQony59nFesjmd50DuoBmhpcjS9utdNAMAngEvq_voQQibdKSVKM_QWQ55RSmZoZ8rbYOJZmviLVa2xWHUusWuw43r3eTxazeOvfa4690OD2ocjb1J2jAqn7idiet0stHYyU0B79RW_77iPI5rjVsddRONs3vbrbbRm2bqlcdBj1H1Se-SHh6ie53qg350XM_Rl8s3V4t32fLT2_eLV8usppzHjHAhCGNt3TaMFLyuKHSCFRWrIe8qLkDVneBQFzlTVSOoUqJSbU5BC93Qri7O0cXBd5zqQbfNPpDq5ejNoPytdMrIvxVr1vLGbSWBnDIByeDZ0cC775MOUQ4mNLrvldVpCFIAY7TgLIFP_wE3aaQ2fU4SzoEABc4T9eJANd6F4HV3ikJA7huWqWFZMkllqjXhT_6Mf4KPlSY9O-gmRP3jJCv_TZY8pZIfrxfyw9XycvF5tZLXiX9-4Oth8_-XfwGoMMGQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1770104077</pqid></control><display><type>article</type><title>Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects</title><source>Open Access: PubMed Central</source><creator>Linker, D T ; Rossvoll, O ; Chapman, J V ; Angelsen, B A</creator><creatorcontrib>Linker, D T ; Rossvoll, O ; Chapman, J V ; Angelsen, B A</creatorcontrib><description>Twenty nine patients (aged from three months to 37 years) with confirmed or suspected ventricular septal defects were studied separately by three examiners who used colour flow mapping and imaging, or continuous wave Doppler and imaging, or a combined reference examination. Colour flow mapping identified 19 of the 25 patients with a ventricular septal defect, continuous wave Doppler echocardiography identified 18, and the combined reference examination identified 24. Two of four patients without ventricular septal defect had a false positive result with colour flow mapping and none had a false positive result with continuous wave Doppler examination. During the reference examination continuous wave Doppler identified 24 patients with ventricular septal defects and colour flow mapping identified 23. In two patients a second ventricular septal defect was found by colour flow mapping, and confirmed by continuous wave Doppler. There was no significant difference in time to diagnosis between the two techniques. Colour flow mapping aids identification of multiple ventricular septal defects but is not faster and has lower specificity than continuous wave Doppler. A combination of the two techniques gave the highest sensitivity and specificity.</description><identifier>ISSN: 0007-0769</identifier><identifier>ISSN: 1355-6037</identifier><identifier>EISSN: 1468-201X</identifier><identifier>EISSN: 2053-5864</identifier><identifier>DOI: 10.1136/hrt.65.4.201</identifier><identifier>PMID: 2029441</identifier><language>eng</language><publisher>England: BMJ Publishing Group Ltd and British Cardiovascular Society</publisher><subject>Adolescent ; Adult ; Child ; Child, Preschool ; Echocardiography, Doppler ; False Negative Reactions ; Heart Septal Defects, Ventricular - diagnosis ; Humans ; Infant ; Time Factors</subject><ispartof>British Heart Journal, 1991-04, Vol.65 (4), p.201-203</ispartof><rights>Copyright BMJ Publishing Group LTD Apr 1991</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-b477t-1788155dbdc5137b940f85395b02f9780abf870b325a9c84aa89ad240e8ec4fb3</citedby><cites>FETCH-LOGICAL-b477t-1788155dbdc5137b940f85395b02f9780abf870b325a9c84aa89ad240e8ec4fb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC1024580/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC1024580/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2029441$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Linker, D T</creatorcontrib><creatorcontrib>Rossvoll, O</creatorcontrib><creatorcontrib>Chapman, J V</creatorcontrib><creatorcontrib>Angelsen, B A</creatorcontrib><title>Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects</title><title>British Heart Journal</title><addtitle>Br Heart J</addtitle><description>Twenty nine patients (aged from three months to 37 years) with confirmed or suspected ventricular septal defects were studied separately by three examiners who used colour flow mapping and imaging, or continuous wave Doppler and imaging, or a combined reference examination. Colour flow mapping identified 19 of the 25 patients with a ventricular septal defect, continuous wave Doppler echocardiography identified 18, and the combined reference examination identified 24. Two of four patients without ventricular septal defect had a false positive result with colour flow mapping and none had a false positive result with continuous wave Doppler examination. During the reference examination continuous wave Doppler identified 24 patients with ventricular septal defects and colour flow mapping identified 23. In two patients a second ventricular septal defect was found by colour flow mapping, and confirmed by continuous wave Doppler. There was no significant difference in time to diagnosis between the two techniques. Colour flow mapping aids identification of multiple ventricular septal defects but is not faster and has lower specificity than continuous wave Doppler. A combination of the two techniques gave the highest sensitivity and specificity.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Child</subject><subject>Child, Preschool</subject><subject>Echocardiography, Doppler</subject><subject>False Negative Reactions</subject><subject>Heart Septal Defects, Ventricular - diagnosis</subject><subject>Humans</subject><subject>Infant</subject><subject>Time Factors</subject><issn>0007-0769</issn><issn>1355-6037</issn><issn>1468-201X</issn><issn>2053-5864</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1991</creationdate><recordtype>article</recordtype><recordid>eNp9kc2O0zAUhS0EGsrAji2SJSTYkHKd2LGzGQkVBpAKSHQYsbOcxJm6JHawnZZ5BZ4aV63Kz4KVbZ3Px8f3IPSYwJyQony59nFesjmd50DuoBmhpcjS9utdNAMAngEvq_voQQibdKSVKM_QWQ55RSmZoZ8rbYOJZmviLVa2xWHUusWuw43r3eTxazeOvfa4690OD2ocjb1J2jAqn7idiet0stHYyU0B79RW_77iPI5rjVsddRONs3vbrbbRm2bqlcdBj1H1Se-SHh6ie53qg350XM_Rl8s3V4t32fLT2_eLV8usppzHjHAhCGNt3TaMFLyuKHSCFRWrIe8qLkDVneBQFzlTVSOoUqJSbU5BC93Qri7O0cXBd5zqQbfNPpDq5ejNoPytdMrIvxVr1vLGbSWBnDIByeDZ0cC775MOUQ4mNLrvldVpCFIAY7TgLIFP_wE3aaQ2fU4SzoEABc4T9eJANd6F4HV3ikJA7huWqWFZMkllqjXhT_6Mf4KPlSY9O-gmRP3jJCv_TZY8pZIfrxfyw9XycvF5tZLXiX9-4Oth8_-XfwGoMMGQ</recordid><startdate>19910401</startdate><enddate>19910401</enddate><creator>Linker, D T</creator><creator>Rossvoll, O</creator><creator>Chapman, J V</creator><creator>Angelsen, B A</creator><general>BMJ Publishing Group Ltd and British Cardiovascular Society</general><general>BMJ Publishing Group LTD</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>88I</scope><scope>8AF</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BTHHO</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>19910401</creationdate><title>Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects</title><author>Linker, D T ; Rossvoll, O ; Chapman, J V ; Angelsen, B A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-b477t-1788155dbdc5137b940f85395b02f9780abf870b325a9c84aa89ad240e8ec4fb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1991</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Child</topic><topic>Child, Preschool</topic><topic>Echocardiography, Doppler</topic><topic>False Negative Reactions</topic><topic>Heart Septal Defects, Ventricular - diagnosis</topic><topic>Humans</topic><topic>Infant</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Linker, D T</creatorcontrib><creatorcontrib>Rossvoll, O</creatorcontrib><creatorcontrib>Chapman, J V</creatorcontrib><creatorcontrib>Angelsen, B A</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>STEM Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>BMJ Journals</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Science Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>British Heart Journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Linker, D T</au><au>Rossvoll, O</au><au>Chapman, J V</au><au>Angelsen, B A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects</atitle><jtitle>British Heart Journal</jtitle><addtitle>Br Heart J</addtitle><date>1991-04-01</date><risdate>1991</risdate><volume>65</volume><issue>4</issue><spage>201</spage><epage>203</epage><pages>201-203</pages><issn>0007-0769</issn><issn>1355-6037</issn><eissn>1468-201X</eissn><eissn>2053-5864</eissn><abstract>Twenty nine patients (aged from three months to 37 years) with confirmed or suspected ventricular septal defects were studied separately by three examiners who used colour flow mapping and imaging, or continuous wave Doppler and imaging, or a combined reference examination. Colour flow mapping identified 19 of the 25 patients with a ventricular septal defect, continuous wave Doppler echocardiography identified 18, and the combined reference examination identified 24. Two of four patients without ventricular septal defect had a false positive result with colour flow mapping and none had a false positive result with continuous wave Doppler examination. During the reference examination continuous wave Doppler identified 24 patients with ventricular septal defects and colour flow mapping identified 23. In two patients a second ventricular septal defect was found by colour flow mapping, and confirmed by continuous wave Doppler. There was no significant difference in time to diagnosis between the two techniques. Colour flow mapping aids identification of multiple ventricular septal defects but is not faster and has lower specificity than continuous wave Doppler. A combination of the two techniques gave the highest sensitivity and specificity.</abstract><cop>England</cop><pub>BMJ Publishing Group Ltd and British Cardiovascular Society</pub><pmid>2029441</pmid><doi>10.1136/hrt.65.4.201</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0007-0769 |
ispartof | British Heart Journal, 1991-04, Vol.65 (4), p.201-203 |
issn | 0007-0769 1355-6037 1468-201X 2053-5864 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1024580 |
source | Open Access: PubMed Central |
subjects | Adolescent Adult Child Child, Preschool Echocardiography, Doppler False Negative Reactions Heart Septal Defects, Ventricular - diagnosis Humans Infant Time Factors |
title | Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T17%3A46%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitivity%20and%20speed%20of%20colour%20Doppler%20flow%20mapping%20compared%20with%20continuous%20wave%20Doppler%20for%20the%20detection%20of%20ventricular%20septal%20defects&rft.jtitle=British%20Heart%20Journal&rft.au=Linker,%20D%20T&rft.date=1991-04-01&rft.volume=65&rft.issue=4&rft.spage=201&rft.epage=203&rft.pages=201-203&rft.issn=0007-0769&rft.eissn=1468-201X&rft_id=info:doi/10.1136/hrt.65.4.201&rft_dat=%3Cproquest_pubme%3E80554375%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-b477t-1788155dbdc5137b940f85395b02f9780abf870b325a9c84aa89ad240e8ec4fb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1770104077&rft_id=info:pmid/2029441&rfr_iscdi=true |