Management of an Inadvertently Placed Transarterial Pacemaker Lead in the Left Ventricle: A Step-by-step Approach

Inadvertent lead misplacement in the left ventricle can lead to thromboembolic events, valvular damage, and endocarditis. We present a case of an inadvertently placed transarterial pacemaker lead in the left ventricle in a patient who underwent percutaneous lead removal. After a multidisciplinary te...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of innovations in cardiac rhythm management (Print) 2023-06, Vol.14 (6), p.5482-5487
Main Authors: Kewcharoen, Jakrin, Contractor, Tahmeed, Kotak, Kamal, Prasad, Vinoy
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c2794-32de9bf3d8608c976a094bca109575bb628c9ab583374efbe52a6fd06ca3ed3f3
cites
container_end_page 5487
container_issue 6
container_start_page 5482
container_title The Journal of innovations in cardiac rhythm management (Print)
container_volume 14
creator Kewcharoen, Jakrin
Contractor, Tahmeed
Kotak, Kamal
Prasad, Vinoy
description Inadvertent lead misplacement in the left ventricle can lead to thromboembolic events, valvular damage, and endocarditis. We present a case of an inadvertently placed transarterial pacemaker lead in the left ventricle in a patient who underwent percutaneous lead removal. After a multidisciplinary team discussion involving cardiac electrophysiology and interventional cardiology as well as a discussion of treatment options with the patient, it was decided to proceed with pacemaker lead removal with the Sentinel™ Cerebral Protection System (Boston Scientific, Marlborough, MA, USA) to prevent thromboembolic events. The patient tolerated the procedure well without post-procedural complications and was discharged the next day on oral anticoagulation. We also present a step-by-step approach to perform lead removal with the use of Sentinel™, emphasizing mitigating the stroke and bleeding risks in this patient setting.
doi_str_mv 10.19102/icrm.2023.14064
format article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10306246</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>37388424</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2794-32de9bf3d8608c976a094bca109575bb628c9ab583374efbe52a6fd06ca3ed3f3</originalsourceid><addsrcrecordid>eNpVUctOwzAQtBCIVtA7J-QfSPEjsWMuqKp4VCqiEoWrtXHsNpAXTkDq3-O2UMFpRrOa2dUOQheUjKmihF0VxldjRhgf05iI-AgNGU1ExJXixwcu5QCNuu6NEMISypkkp2jAJU_TmMVD9PEINaxsZeseNw5DjWc15F_W90EpN3hRgrE5XnqoOwiiL6DEi6BV8G49nlvIcVHjfm0Ddz1-DTZfmNJe4wl-7m0bZZuoC4gnbesbMOtzdOKg7OzoB8_Qy93tcvoQzZ_uZ9PJPDJMqjjiLLcqczxPBUmNkgKIijMDlKhEJlkmWFAhS1LOZWxdZhMGwuVEGOA2546foZt9bvuZVTY328Og1K0vKvAb3UCh_0_qYq1XzZemhBPBYhESyD7B-KbrvHUHMyV6V4HeVqC3FehdBcFy-XfpwfD7cP4NrfeEtg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Management of an Inadvertently Placed Transarterial Pacemaker Lead in the Left Ventricle: A Step-by-step Approach</title><source>PubMed Central</source><creator>Kewcharoen, Jakrin ; Contractor, Tahmeed ; Kotak, Kamal ; Prasad, Vinoy</creator><creatorcontrib>Kewcharoen, Jakrin ; Contractor, Tahmeed ; Kotak, Kamal ; Prasad, Vinoy</creatorcontrib><description>Inadvertent lead misplacement in the left ventricle can lead to thromboembolic events, valvular damage, and endocarditis. We present a case of an inadvertently placed transarterial pacemaker lead in the left ventricle in a patient who underwent percutaneous lead removal. After a multidisciplinary team discussion involving cardiac electrophysiology and interventional cardiology as well as a discussion of treatment options with the patient, it was decided to proceed with pacemaker lead removal with the Sentinel™ Cerebral Protection System (Boston Scientific, Marlborough, MA, USA) to prevent thromboembolic events. The patient tolerated the procedure well without post-procedural complications and was discharged the next day on oral anticoagulation. We also present a step-by-step approach to perform lead removal with the use of Sentinel™, emphasizing mitigating the stroke and bleeding risks in this patient setting.</description><identifier>ISSN: 2156-3977</identifier><identifier>EISSN: 2156-3993</identifier><identifier>DOI: 10.19102/icrm.2023.14064</identifier><identifier>PMID: 37388424</identifier><language>eng</language><publisher>United States: MediaSphere Medical</publisher><subject>Case Report</subject><ispartof>The Journal of innovations in cardiac rhythm management (Print), 2023-06, Vol.14 (6), p.5482-5487</ispartof><rights>Copyright: © 2023 Innovations in Cardiac Rhythm Management.</rights><rights>Copyright: © 2023 Innovations in Cardiac Rhythm Management 2023</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2794-32de9bf3d8608c976a094bca109575bb628c9ab583374efbe52a6fd06ca3ed3f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10306246/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10306246/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37388424$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kewcharoen, Jakrin</creatorcontrib><creatorcontrib>Contractor, Tahmeed</creatorcontrib><creatorcontrib>Kotak, Kamal</creatorcontrib><creatorcontrib>Prasad, Vinoy</creatorcontrib><title>Management of an Inadvertently Placed Transarterial Pacemaker Lead in the Left Ventricle: A Step-by-step Approach</title><title>The Journal of innovations in cardiac rhythm management (Print)</title><addtitle>J Innov Card Rhythm Manag</addtitle><description>Inadvertent lead misplacement in the left ventricle can lead to thromboembolic events, valvular damage, and endocarditis. We present a case of an inadvertently placed transarterial pacemaker lead in the left ventricle in a patient who underwent percutaneous lead removal. After a multidisciplinary team discussion involving cardiac electrophysiology and interventional cardiology as well as a discussion of treatment options with the patient, it was decided to proceed with pacemaker lead removal with the Sentinel™ Cerebral Protection System (Boston Scientific, Marlborough, MA, USA) to prevent thromboembolic events. The patient tolerated the procedure well without post-procedural complications and was discharged the next day on oral anticoagulation. We also present a step-by-step approach to perform lead removal with the use of Sentinel™, emphasizing mitigating the stroke and bleeding risks in this patient setting.</description><subject>Case Report</subject><issn>2156-3977</issn><issn>2156-3993</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNpVUctOwzAQtBCIVtA7J-QfSPEjsWMuqKp4VCqiEoWrtXHsNpAXTkDq3-O2UMFpRrOa2dUOQheUjKmihF0VxldjRhgf05iI-AgNGU1ExJXixwcu5QCNuu6NEMISypkkp2jAJU_TmMVD9PEINaxsZeseNw5DjWc15F_W90EpN3hRgrE5XnqoOwiiL6DEi6BV8G49nlvIcVHjfm0Ddz1-DTZfmNJe4wl-7m0bZZuoC4gnbesbMOtzdOKg7OzoB8_Qy93tcvoQzZ_uZ9PJPDJMqjjiLLcqczxPBUmNkgKIijMDlKhEJlkmWFAhS1LOZWxdZhMGwuVEGOA2546foZt9bvuZVTY328Og1K0vKvAb3UCh_0_qYq1XzZemhBPBYhESyD7B-KbrvHUHMyV6V4HeVqC3FehdBcFy-XfpwfD7cP4NrfeEtg</recordid><startdate>202306</startdate><enddate>202306</enddate><creator>Kewcharoen, Jakrin</creator><creator>Contractor, Tahmeed</creator><creator>Kotak, Kamal</creator><creator>Prasad, Vinoy</creator><general>MediaSphere Medical</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>5PM</scope></search><sort><creationdate>202306</creationdate><title>Management of an Inadvertently Placed Transarterial Pacemaker Lead in the Left Ventricle: A Step-by-step Approach</title><author>Kewcharoen, Jakrin ; Contractor, Tahmeed ; Kotak, Kamal ; Prasad, Vinoy</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2794-32de9bf3d8608c976a094bca109575bb628c9ab583374efbe52a6fd06ca3ed3f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Case Report</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kewcharoen, Jakrin</creatorcontrib><creatorcontrib>Contractor, Tahmeed</creatorcontrib><creatorcontrib>Kotak, Kamal</creatorcontrib><creatorcontrib>Prasad, Vinoy</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>The Journal of innovations in cardiac rhythm management (Print)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kewcharoen, Jakrin</au><au>Contractor, Tahmeed</au><au>Kotak, Kamal</au><au>Prasad, Vinoy</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Management of an Inadvertently Placed Transarterial Pacemaker Lead in the Left Ventricle: A Step-by-step Approach</atitle><jtitle>The Journal of innovations in cardiac rhythm management (Print)</jtitle><addtitle>J Innov Card Rhythm Manag</addtitle><date>2023-06</date><risdate>2023</risdate><volume>14</volume><issue>6</issue><spage>5482</spage><epage>5487</epage><pages>5482-5487</pages><issn>2156-3977</issn><eissn>2156-3993</eissn><abstract>Inadvertent lead misplacement in the left ventricle can lead to thromboembolic events, valvular damage, and endocarditis. We present a case of an inadvertently placed transarterial pacemaker lead in the left ventricle in a patient who underwent percutaneous lead removal. After a multidisciplinary team discussion involving cardiac electrophysiology and interventional cardiology as well as a discussion of treatment options with the patient, it was decided to proceed with pacemaker lead removal with the Sentinel™ Cerebral Protection System (Boston Scientific, Marlborough, MA, USA) to prevent thromboembolic events. The patient tolerated the procedure well without post-procedural complications and was discharged the next day on oral anticoagulation. We also present a step-by-step approach to perform lead removal with the use of Sentinel™, emphasizing mitigating the stroke and bleeding risks in this patient setting.</abstract><cop>United States</cop><pub>MediaSphere Medical</pub><pmid>37388424</pmid><doi>10.19102/icrm.2023.14064</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2156-3977
ispartof The Journal of innovations in cardiac rhythm management (Print), 2023-06, Vol.14 (6), p.5482-5487
issn 2156-3977
2156-3993
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10306246
source PubMed Central
subjects Case Report
title Management of an Inadvertently Placed Transarterial Pacemaker Lead in the Left Ventricle: A Step-by-step Approach
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T02%3A20%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Management%20of%20an%20Inadvertently%20Placed%20Transarterial%20Pacemaker%20Lead%20in%20the%20Left%20Ventricle:%20A%20Step-by-step%20Approach&rft.jtitle=The%20Journal%20of%20innovations%20in%20cardiac%20rhythm%20management%20(Print)&rft.au=Kewcharoen,%20Jakrin&rft.date=2023-06&rft.volume=14&rft.issue=6&rft.spage=5482&rft.epage=5487&rft.pages=5482-5487&rft.issn=2156-3977&rft.eissn=2156-3993&rft_id=info:doi/10.19102/icrm.2023.14064&rft_dat=%3Cpubmed_cross%3E37388424%3C/pubmed_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2794-32de9bf3d8608c976a094bca109575bb628c9ab583374efbe52a6fd06ca3ed3f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/37388424&rfr_iscdi=true