Loading…

Evaluation of EuroQol Valuation Technology (EQ-VT) Designs to Generate National Value Sets: Learnings from the Development of an EQ-5D Value Set for India Using an Extended Design (DEVINE) Study

Introduction Countries develop their EQ-5D-5L value sets using the EuroQol Valuation Technology (EQ-VT) protocol. This study aims to assess if extension in the conventional EQ-VT design can lead to development of value sets with improved precision. Methods A cross-sectional survey was undertaken in...

Full description

Saved in:
Bibliographic Details
Published in:Medical decision making 2023-08, Vol.43 (6), p.692-703
Main Authors: Jyani, Gaurav, Yang, Zhihao, Sharma, Atul, Goyal, Aarti, Stolk, Elly, Purba, Fredrick Dermawan, Grover, Sandeep, Kaur, Manmeet, Prinja, Shankar
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction Countries develop their EQ-5D-5L value sets using the EuroQol Valuation Technology (EQ-VT) protocol. This study aims to assess if extension in the conventional EQ-VT design can lead to development of value sets with improved precision. Methods A cross-sectional survey was undertaken in a representative sample of 3,548 adult respondents, selected from 5 different states of India using a multistage stratified random sampling technique. A novel extended EQ-VT design was created that included 18 blocks of 10 health states, comprising 150 unique health states and 135 observations per health state. In addition to the standard EQ-VT design, which is based on 86 health states and 100 observations per health state, 3 extended designs were assessed for their predictive performance. The extended designs were created by 1) increasing the number of observations per health state in the design, 2) increasing the number of health states in the design, and 3) implementing both 1) and 2) at the same time. Subsamples of the data set were created for separate designs. The root mean squared error (RMSE) and mean absolute error (MAE) were used to measure the predictive accuracy of the conventional and extended designs. Results The average RMSE and MAE for the standard EQ-VT design were 0.055 and 0.041, respectively, for the 150 health states. All 3 types of design extensions showed lower RMSE and MAE values as compared with the standard design and hence yielded better predictive performance. RMSE and MAE were lowest (0.051 and 0.039, respectively) for the designs that use a greater number of health states. Extending the design with inclusion of more health states was shown to improve the predictive performance even when the sample size was fixed at 1,000. Conclusion Although the standard EQ-VT design performs well, its prediction accuracy can be further improved by extending its design. The addition of more health states in EQ-VT is more beneficial than increasing the number of observations per health state. Highlights The EQ-5D-5L value sets are developed using the standardized EuroQol Valuation Technology (EQ-VT) protocol. This is the first study to empirically assess how much can be gained from extending the standard EQ-VT design in terms of sample size and/or health states. It not only presents useful insights into the performance of the standard design of the EQ-VT but also tests the potential extensions in the standard EQ-VT design in terms of increasing the
ISSN:0272-989X
1552-681X
DOI:10.1177/0272989X231180134