Impact of Fingernail Polish on Pulse Oximetry Measurements: A Systematic Review

The effect of application of fingernail polish on S measurement remains unclear. We conducted this systematic review to ascertain the impact of fingernail polish on S measurement. We queried PubMed, Embase, and CINAHL databases for publications indexed through December 2022. We included studies prov...

Full description

Saved in:
Bibliographic Details
Published in:Respiratory care 2023-09, Vol.68 (9), p.1271-1280
Main Authors: Aggarwal, Ashutosh Nath, Agarwal, Ritesh, Dhooria, Sahajal, Prasad, Kuruswamy Thurai, Sehgal, Inderpaul Singh, Muthu, Valliappan
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c489t-c3e4dfeacf131197505f6b16002fc7839587c101adef833ba8adaddc01bf0cf53
cites
container_end_page 1280
container_issue 9
container_start_page 1271
container_title Respiratory care
container_volume 68
creator Aggarwal, Ashutosh Nath
Agarwal, Ritesh
Dhooria, Sahajal
Prasad, Kuruswamy Thurai
Sehgal, Inderpaul Singh
Muthu, Valliappan
description The effect of application of fingernail polish on S measurement remains unclear. We conducted this systematic review to ascertain the impact of fingernail polish on S measurement. We queried PubMed, Embase, and CINAHL databases for publications indexed through December 2022. We included studies providing paired S data from fingertips without and after nail polish application or reporting the number of subjects whose S could not be measured due to fingernail polish. We used random effects modeling to summarize standardized mean differences (SMDs) and corresponding 95% CI for different nail polish colors from comparative studies. We retrieved 122 studies and included 21 publications, mostly performed on healthy volunteers. Of these, 17 (81.0%) studies had a low risk of bias. We summarized mean SMD for 10 nail polish colors (black, blue, brown, green, orange, pink, purple, red, white, and yellow) from 25 paired data sets on S across 20 studies. We found small (likely clinically insignificant) but statistically significant differences in mean S when fingers were coated with black, blue, brown, or purple nail polish (SMD -0.57, -0.47, -0.33, and -0.25, respectively; 95% CI -0.86 to -0.29, -0.84 to -0.10, -0.59 to -0.07, and -0.48 to -0.02, respectively). Only one of 4 studies reported a high proportion of unsuccessful oximeter readings from fingers painted with black (88.0%) or brown (36.0%) nail polish. Although fingernail polish of some colors can marginally reduce S reading or occasionally impede S measurement, the variability is clinically insignificant.
doi_str_mv 10.4187/respcare.10399
format article
fullrecord <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10468177</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A786213029</galeid><sourcerecordid>A786213029</sourcerecordid><originalsourceid>FETCH-LOGICAL-c489t-c3e4dfeacf131197505f6b16002fc7839587c101adef833ba8adaddc01bf0cf53</originalsourceid><addsrcrecordid>eNptkt1vFCEUxYmxsWv11UdDYmJ8mZU7zAfji9k01jap2cbWZ8Iyl13MDGyBqe5_L2s_0iYNDwQ458flcgh5B2xegWg_B4xbrQLOgfGue0Fm0FW84E1dvSQzxkpWAC-rQ_I6xt952VR194oc8hZEDcBnZHk2bpVO1Bt6Yt0ag1N2oBd-sHFDvaMX0xCRLv_aEVPY0R-o4hRwRJfiF7qgl7uYcFTJavoTbyz-eUMOjMqWt3fzEfl18u3q-LQ4X34_O16cF7oSXSo0x6o3qLQBDtC1NatNs4Iml2h0K3hXi1YDA9WjEZyvlFC96nvNYGWYNjU_Il9vudtpNWKvc0FBDXIb7KjCTnpl5dMTZzdy7W8ksKoR0LaZ8OmOEPz1hDHJ0UaNw6Ac-inKUkBVl7mT-8s-3ErXakBpnfEZqfdyuWhFUwJnZZdV82dUefQ4Wu0dGpv3nxg-PjJsUA1pE_0wJetdfJasg48xoHl4JzC5j4G8j4H8H4NseP-4Ow_y-3_n_wDt6q9W</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2814523655</pqid></control><display><type>article</type><title>Impact of Fingernail Polish on Pulse Oximetry Measurements: A Systematic Review</title><source>PubMed Central</source><creator>Aggarwal, Ashutosh Nath ; Agarwal, Ritesh ; Dhooria, Sahajal ; Prasad, Kuruswamy Thurai ; Sehgal, Inderpaul Singh ; Muthu, Valliappan</creator><creatorcontrib>Aggarwal, Ashutosh Nath ; Agarwal, Ritesh ; Dhooria, Sahajal ; Prasad, Kuruswamy Thurai ; Sehgal, Inderpaul Singh ; Muthu, Valliappan</creatorcontrib><description>The effect of application of fingernail polish on S measurement remains unclear. We conducted this systematic review to ascertain the impact of fingernail polish on S measurement. We queried PubMed, Embase, and CINAHL databases for publications indexed through December 2022. We included studies providing paired S data from fingertips without and after nail polish application or reporting the number of subjects whose S could not be measured due to fingernail polish. We used random effects modeling to summarize standardized mean differences (SMDs) and corresponding 95% CI for different nail polish colors from comparative studies. We retrieved 122 studies and included 21 publications, mostly performed on healthy volunteers. Of these, 17 (81.0%) studies had a low risk of bias. We summarized mean SMD for 10 nail polish colors (black, blue, brown, green, orange, pink, purple, red, white, and yellow) from 25 paired data sets on S across 20 studies. We found small (likely clinically insignificant) but statistically significant differences in mean S when fingers were coated with black, blue, brown, or purple nail polish (SMD -0.57, -0.47, -0.33, and -0.25, respectively; 95% CI -0.86 to -0.29, -0.84 to -0.10, -0.59 to -0.07, and -0.48 to -0.02, respectively). Only one of 4 studies reported a high proportion of unsuccessful oximeter readings from fingers painted with black (88.0%) or brown (36.0%) nail polish. Although fingernail polish of some colors can marginally reduce S reading or occasionally impede S measurement, the variability is clinically insignificant.</description><identifier>ISSN: 0020-1324</identifier><identifier>ISSN: 1943-3654</identifier><identifier>EISSN: 1943-3654</identifier><identifier>DOI: 10.4187/respcare.10399</identifier><identifier>PMID: 37185113</identifier><language>eng</language><publisher>United States: Daedalus Enterprises, Inc</publisher><subject>Color ; Cosmetics ; Humans ; Management ; Nails ; Oximetry ; Oxygen ; Secondary data analysis ; Systematic Review</subject><ispartof>Respiratory care, 2023-09, Vol.68 (9), p.1271-1280</ispartof><rights>Copyright © 2023 by Daedalus Enterprises.</rights><rights>COPYRIGHT 2023 Daedalus Enterprises, Inc.</rights><rights>Copyright © 2023 by Daedalus Enterprises 2023</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c489t-c3e4dfeacf131197505f6b16002fc7839587c101adef833ba8adaddc01bf0cf53</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10468177/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10468177/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37185113$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Aggarwal, Ashutosh Nath</creatorcontrib><creatorcontrib>Agarwal, Ritesh</creatorcontrib><creatorcontrib>Dhooria, Sahajal</creatorcontrib><creatorcontrib>Prasad, Kuruswamy Thurai</creatorcontrib><creatorcontrib>Sehgal, Inderpaul Singh</creatorcontrib><creatorcontrib>Muthu, Valliappan</creatorcontrib><title>Impact of Fingernail Polish on Pulse Oximetry Measurements: A Systematic Review</title><title>Respiratory care</title><addtitle>Respir Care</addtitle><description>The effect of application of fingernail polish on S measurement remains unclear. We conducted this systematic review to ascertain the impact of fingernail polish on S measurement. We queried PubMed, Embase, and CINAHL databases for publications indexed through December 2022. We included studies providing paired S data from fingertips without and after nail polish application or reporting the number of subjects whose S could not be measured due to fingernail polish. We used random effects modeling to summarize standardized mean differences (SMDs) and corresponding 95% CI for different nail polish colors from comparative studies. We retrieved 122 studies and included 21 publications, mostly performed on healthy volunteers. Of these, 17 (81.0%) studies had a low risk of bias. We summarized mean SMD for 10 nail polish colors (black, blue, brown, green, orange, pink, purple, red, white, and yellow) from 25 paired data sets on S across 20 studies. We found small (likely clinically insignificant) but statistically significant differences in mean S when fingers were coated with black, blue, brown, or purple nail polish (SMD -0.57, -0.47, -0.33, and -0.25, respectively; 95% CI -0.86 to -0.29, -0.84 to -0.10, -0.59 to -0.07, and -0.48 to -0.02, respectively). Only one of 4 studies reported a high proportion of unsuccessful oximeter readings from fingers painted with black (88.0%) or brown (36.0%) nail polish. Although fingernail polish of some colors can marginally reduce S reading or occasionally impede S measurement, the variability is clinically insignificant.</description><subject>Color</subject><subject>Cosmetics</subject><subject>Humans</subject><subject>Management</subject><subject>Nails</subject><subject>Oximetry</subject><subject>Oxygen</subject><subject>Secondary data analysis</subject><subject>Systematic Review</subject><issn>0020-1324</issn><issn>1943-3654</issn><issn>1943-3654</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNptkt1vFCEUxYmxsWv11UdDYmJ8mZU7zAfji9k01jap2cbWZ8Iyl13MDGyBqe5_L2s_0iYNDwQ458flcgh5B2xegWg_B4xbrQLOgfGue0Fm0FW84E1dvSQzxkpWAC-rQ_I6xt952VR194oc8hZEDcBnZHk2bpVO1Bt6Yt0ag1N2oBd-sHFDvaMX0xCRLv_aEVPY0R-o4hRwRJfiF7qgl7uYcFTJavoTbyz-eUMOjMqWt3fzEfl18u3q-LQ4X34_O16cF7oSXSo0x6o3qLQBDtC1NatNs4Iml2h0K3hXi1YDA9WjEZyvlFC96nvNYGWYNjU_Il9vudtpNWKvc0FBDXIb7KjCTnpl5dMTZzdy7W8ksKoR0LaZ8OmOEPz1hDHJ0UaNw6Ac-inKUkBVl7mT-8s-3ErXakBpnfEZqfdyuWhFUwJnZZdV82dUefQ4Wu0dGpv3nxg-PjJsUA1pE_0wJetdfJasg48xoHl4JzC5j4G8j4H8H4NseP-4Ow_y-3_n_wDt6q9W</recordid><startdate>202309</startdate><enddate>202309</enddate><creator>Aggarwal, Ashutosh Nath</creator><creator>Agarwal, Ritesh</creator><creator>Dhooria, Sahajal</creator><creator>Prasad, Kuruswamy Thurai</creator><creator>Sehgal, Inderpaul Singh</creator><creator>Muthu, Valliappan</creator><general>Daedalus Enterprises, Inc</general><general>Daedalus Enterprises Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>202309</creationdate><title>Impact of Fingernail Polish on Pulse Oximetry Measurements: A Systematic Review</title><author>Aggarwal, Ashutosh Nath ; Agarwal, Ritesh ; Dhooria, Sahajal ; Prasad, Kuruswamy Thurai ; Sehgal, Inderpaul Singh ; Muthu, Valliappan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c489t-c3e4dfeacf131197505f6b16002fc7839587c101adef833ba8adaddc01bf0cf53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Color</topic><topic>Cosmetics</topic><topic>Humans</topic><topic>Management</topic><topic>Nails</topic><topic>Oximetry</topic><topic>Oxygen</topic><topic>Secondary data analysis</topic><topic>Systematic Review</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aggarwal, Ashutosh Nath</creatorcontrib><creatorcontrib>Agarwal, Ritesh</creatorcontrib><creatorcontrib>Dhooria, Sahajal</creatorcontrib><creatorcontrib>Prasad, Kuruswamy Thurai</creatorcontrib><creatorcontrib>Sehgal, Inderpaul Singh</creatorcontrib><creatorcontrib>Muthu, Valliappan</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Respiratory care</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aggarwal, Ashutosh Nath</au><au>Agarwal, Ritesh</au><au>Dhooria, Sahajal</au><au>Prasad, Kuruswamy Thurai</au><au>Sehgal, Inderpaul Singh</au><au>Muthu, Valliappan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of Fingernail Polish on Pulse Oximetry Measurements: A Systematic Review</atitle><jtitle>Respiratory care</jtitle><addtitle>Respir Care</addtitle><date>2023-09</date><risdate>2023</risdate><volume>68</volume><issue>9</issue><spage>1271</spage><epage>1280</epage><pages>1271-1280</pages><issn>0020-1324</issn><issn>1943-3654</issn><eissn>1943-3654</eissn><abstract>The effect of application of fingernail polish on S measurement remains unclear. We conducted this systematic review to ascertain the impact of fingernail polish on S measurement. We queried PubMed, Embase, and CINAHL databases for publications indexed through December 2022. We included studies providing paired S data from fingertips without and after nail polish application or reporting the number of subjects whose S could not be measured due to fingernail polish. We used random effects modeling to summarize standardized mean differences (SMDs) and corresponding 95% CI for different nail polish colors from comparative studies. We retrieved 122 studies and included 21 publications, mostly performed on healthy volunteers. Of these, 17 (81.0%) studies had a low risk of bias. We summarized mean SMD for 10 nail polish colors (black, blue, brown, green, orange, pink, purple, red, white, and yellow) from 25 paired data sets on S across 20 studies. We found small (likely clinically insignificant) but statistically significant differences in mean S when fingers were coated with black, blue, brown, or purple nail polish (SMD -0.57, -0.47, -0.33, and -0.25, respectively; 95% CI -0.86 to -0.29, -0.84 to -0.10, -0.59 to -0.07, and -0.48 to -0.02, respectively). Only one of 4 studies reported a high proportion of unsuccessful oximeter readings from fingers painted with black (88.0%) or brown (36.0%) nail polish. Although fingernail polish of some colors can marginally reduce S reading or occasionally impede S measurement, the variability is clinically insignificant.</abstract><cop>United States</cop><pub>Daedalus Enterprises, Inc</pub><pmid>37185113</pmid><doi>10.4187/respcare.10399</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0020-1324
ispartof Respiratory care, 2023-09, Vol.68 (9), p.1271-1280
issn 0020-1324
1943-3654
1943-3654
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10468177
source PubMed Central
subjects Color
Cosmetics
Humans
Management
Nails
Oximetry
Oxygen
Secondary data analysis
Systematic Review
title Impact of Fingernail Polish on Pulse Oximetry Measurements: A Systematic Review
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T02%3A16%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20Fingernail%20Polish%20on%20Pulse%20Oximetry%20Measurements:%20A%20Systematic%20Review&rft.jtitle=Respiratory%20care&rft.au=Aggarwal,%20Ashutosh%20Nath&rft.date=2023-09&rft.volume=68&rft.issue=9&rft.spage=1271&rft.epage=1280&rft.pages=1271-1280&rft.issn=0020-1324&rft.eissn=1943-3654&rft_id=info:doi/10.4187/respcare.10399&rft_dat=%3Cgale_pubme%3EA786213029%3C/gale_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c489t-c3e4dfeacf131197505f6b16002fc7839587c101adef833ba8adaddc01bf0cf53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2814523655&rft_id=info:pmid/37185113&rft_galeid=A786213029&rfr_iscdi=true