Loading…

Prediction of Weaning Outcome from Mechanical Ventilation Using Ultrasound Assessment of Parasternal Intercostal Muscle Thickness

Monitoring the function of parasternal intercostal muscles provides information on respiratory load and capacity and thus can be a weaning monitoring tool. The goal was to study the diagnostic accuracy of parasternal intercostal muscle thickness fraction (PICTF%) as a predictor of weaning. A prospec...

Full description

Saved in:
Bibliographic Details
Published in:Indian journal of critical care medicine 2023-10, Vol.27 (10), p.704-708
Main Authors: Ramaswamy, Arjun, Kumar, Rohit, Arul, Mahendran, Ish, Pranav, Madan, Manu, Gupta, Neeraj Kumar, Gupta, Nitesh
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Monitoring the function of parasternal intercostal muscles provides information on respiratory load and capacity and thus can be a weaning monitoring tool. The goal was to study the diagnostic accuracy of parasternal intercostal muscle thickness fraction (PICTF%) as a predictor of weaning. A prospective observational study on consecutively admitted patients who were intubated and mechanically ventilated for a duration of at least 48 hours was carried out. When an SBT was planned by the treating physician, the study examiner performed the ultrasound measurements of parasternal intercostal muscle thickness (inspiration and expiration) and thickening fraction using M-mode ultrasonography (USG). The PICTF% was calculated as "(peak inspiratory thickness - end-expiratory thickness)/end-expiratory thickness) × 100." Weaning failure was defined if the patient had a failed spontaneous breathing trial (SBT) or the need for a reintubation within 48 hours following extubation. The SBT failure was defined as the need to connect the patient back to the ventilator prior to its completion due to any reason as decided by the clinician. Of 81 screened patients, 60 patients met the inclusion criteria, of whom 49 patients had successful SBT, and 48 patients could be successfully extubated. The PMTF% cut-off value more than or equal to 15.38% was associated with the best sensitivity (75%) and specificity (87.8%) in predicting extubation failure. The PICTF% has a good diagnostic accuracy in predicting weaning failure. Ramaswamy A, Kumar R, Arul M, Ish P, Madan M, Gupta NK, . Prediction of Weaning Outcome from Mechanical Ventilation Using Ultrasound Assessment of Parasternal Intercostal Muscle Thickness. Indian J Crit Care Med 2023;27(10):704-708.
ISSN:0972-5229
1998-359X
DOI:10.5005/jp-journals-10071-24548