Loading…

Diagnostic accuracy of MRI–CBCT fused images in assessment of clinically diagnosed internal derangement of the temporomandibular joint

Objectives To evaluate the diagnostic accuracy of Fused (MRI)–CBCT images in the assessment of internal derangement of the temporomandibular joint. Methods MRI and CBCT images of the TMJ were evaluated bilaterally in 10 patients with clinically diagnosed internal derangement. Image fusion was perfor...

Full description

Saved in:
Bibliographic Details
Published in:Oral radiology 2024-04, Vol.40 (2), p.226-233
Main Authors: ElShennawy, Ethar M., Hamed, Walaa M., Samir, Sahar M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c426t-d08ef95a6f4ae4fc6296d549917b7b92c33a67366bff60fc968aa33730c05f123
container_end_page 233
container_issue 2
container_start_page 226
container_title Oral radiology
container_volume 40
creator ElShennawy, Ethar M.
Hamed, Walaa M.
Samir, Sahar M.
description Objectives To evaluate the diagnostic accuracy of Fused (MRI)–CBCT images in the assessment of internal derangement of the temporomandibular joint. Methods MRI and CBCT images of the TMJ were evaluated bilaterally in 10 patients with clinically diagnosed internal derangement. Image fusion was performed using Amira 3D Software (version 5.4.3, Thermo Fisher Scientific Inc.). Results The AUC index for MRI–CBCT fused images was 0.83, which was significantly different from the null hypothesis value of 0.5. This was confirmed by inter-examiner reliability index of 0.87, which is statistically significant. Conclusion MRI–CBCT fused images can significantly improve the accuracy and inter-examiner reliability in the evaluation of clinically diagnosed cases with internal derangement.
doi_str_mv 10.1007/s11282-023-00727-1
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10927775</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2915989029</sourcerecordid><originalsourceid>FETCH-LOGICAL-c426t-d08ef95a6f4ae4fc6296d549917b7b92c33a67366bff60fc968aa33730c05f123</originalsourceid><addsrcrecordid>eNp9kbuO1DAUhi0EYoeFF6BAlmhoAr4kdlwhGG4rLUJCS22dOPasR4k92AnSdJT0vCFPgkN2l0tBZVn-zu9zzofQQ0qeUkLks0wpa1lFGK_KlcmK3kIbKiivlJD1bbQhitJKENaeoHs57wlhqq7bu-iEt4xTTsQGfXvlYRdinrzBYMycwBxxdPj9x7MfX79vX24vsJuz7bEfYWcz9gFDzjbn0YZpAc3ggzcwDEfcr1ELHCabAgy4twnCzl7D06XFkx0PMcURQu-7eYCE97Hw99EdB0O2D67OU_TpzeuL7bvq_MPbs-2L88rUTExVT1rrVAPC1WBrZwRTom9qpajsZKeY4RyE5EJ0zgnijBItAOeSE0MaRxk_Rc_X3MPcjbY3pbMEgz6kMmA66ghe__0S_KXexS-aEsWklE1JeHKVkOLn2eZJjz4bOwwQbJyzZoo2qlVl2QV9_A-6j_OymIVqGl7XTC0UWymTYs7JuptuKNGLab2a1sW0_mVa01L06M85bkqu1RaAr0AuT8VB-v33f2J_AmgAt30</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2955344299</pqid></control><display><type>article</type><title>Diagnostic accuracy of MRI–CBCT fused images in assessment of clinically diagnosed internal derangement of the temporomandibular joint</title><source>Springer Link</source><creator>ElShennawy, Ethar M. ; Hamed, Walaa M. ; Samir, Sahar M.</creator><creatorcontrib>ElShennawy, Ethar M. ; Hamed, Walaa M. ; Samir, Sahar M.</creatorcontrib><description>Objectives To evaluate the diagnostic accuracy of Fused (MRI)–CBCT images in the assessment of internal derangement of the temporomandibular joint. Methods MRI and CBCT images of the TMJ were evaluated bilaterally in 10 patients with clinically diagnosed internal derangement. Image fusion was performed using Amira 3D Software (version 5.4.3, Thermo Fisher Scientific Inc.). Results The AUC index for MRI–CBCT fused images was 0.83, which was significantly different from the null hypothesis value of 0.5. This was confirmed by inter-examiner reliability index of 0.87, which is statistically significant. Conclusion MRI–CBCT fused images can significantly improve the accuracy and inter-examiner reliability in the evaluation of clinically diagnosed cases with internal derangement.</description><identifier>ISSN: 0911-6028</identifier><identifier>EISSN: 1613-9674</identifier><identifier>DOI: 10.1007/s11282-023-00727-1</identifier><identifier>PMID: 38231306</identifier><language>eng</language><publisher>Singapore: Springer Nature Singapore</publisher><subject>Cone-Beam Computed Tomography - methods ; Dentistry ; Humans ; Imaging ; Magnetic resonance imaging ; Magnetic Resonance Imaging - methods ; Medicine ; Oral and Maxillofacial Surgery ; Original ; Original Article ; Radiology ; Reproducibility of Results ; Spiral Cone-Beam Computed Tomography ; Statistical analysis ; Temporomandibular joint ; Temporomandibular Joint - diagnostic imaging ; Temporomandibular Joint Disorders - diagnostic imaging</subject><ispartof>Oral radiology, 2024-04, Vol.40 (2), p.226-233</ispartof><rights>The Author(s) 2024</rights><rights>2024. The Author(s).</rights><rights>The Author(s) 2024. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c426t-d08ef95a6f4ae4fc6296d549917b7b92c33a67366bff60fc968aa33730c05f123</cites><orcidid>0009-0001-2904-4555</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38231306$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ElShennawy, Ethar M.</creatorcontrib><creatorcontrib>Hamed, Walaa M.</creatorcontrib><creatorcontrib>Samir, Sahar M.</creatorcontrib><title>Diagnostic accuracy of MRI–CBCT fused images in assessment of clinically diagnosed internal derangement of the temporomandibular joint</title><title>Oral radiology</title><addtitle>Oral Radiol</addtitle><addtitle>Oral Radiol</addtitle><description>Objectives To evaluate the diagnostic accuracy of Fused (MRI)–CBCT images in the assessment of internal derangement of the temporomandibular joint. Methods MRI and CBCT images of the TMJ were evaluated bilaterally in 10 patients with clinically diagnosed internal derangement. Image fusion was performed using Amira 3D Software (version 5.4.3, Thermo Fisher Scientific Inc.). Results The AUC index for MRI–CBCT fused images was 0.83, which was significantly different from the null hypothesis value of 0.5. This was confirmed by inter-examiner reliability index of 0.87, which is statistically significant. Conclusion MRI–CBCT fused images can significantly improve the accuracy and inter-examiner reliability in the evaluation of clinically diagnosed cases with internal derangement.</description><subject>Cone-Beam Computed Tomography - methods</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Imaging</subject><subject>Magnetic resonance imaging</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Medicine</subject><subject>Oral and Maxillofacial Surgery</subject><subject>Original</subject><subject>Original Article</subject><subject>Radiology</subject><subject>Reproducibility of Results</subject><subject>Spiral Cone-Beam Computed Tomography</subject><subject>Statistical analysis</subject><subject>Temporomandibular joint</subject><subject>Temporomandibular Joint - diagnostic imaging</subject><subject>Temporomandibular Joint Disorders - diagnostic imaging</subject><issn>0911-6028</issn><issn>1613-9674</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kbuO1DAUhi0EYoeFF6BAlmhoAr4kdlwhGG4rLUJCS22dOPasR4k92AnSdJT0vCFPgkN2l0tBZVn-zu9zzofQQ0qeUkLks0wpa1lFGK_KlcmK3kIbKiivlJD1bbQhitJKENaeoHs57wlhqq7bu-iEt4xTTsQGfXvlYRdinrzBYMycwBxxdPj9x7MfX79vX24vsJuz7bEfYWcz9gFDzjbn0YZpAc3ggzcwDEfcr1ELHCabAgy4twnCzl7D06XFkx0PMcURQu-7eYCE97Hw99EdB0O2D67OU_TpzeuL7bvq_MPbs-2L88rUTExVT1rrVAPC1WBrZwRTom9qpajsZKeY4RyE5EJ0zgnijBItAOeSE0MaRxk_Rc_X3MPcjbY3pbMEgz6kMmA66ghe__0S_KXexS-aEsWklE1JeHKVkOLn2eZJjz4bOwwQbJyzZoo2qlVl2QV9_A-6j_OymIVqGl7XTC0UWymTYs7JuptuKNGLab2a1sW0_mVa01L06M85bkqu1RaAr0AuT8VB-v33f2J_AmgAt30</recordid><startdate>20240401</startdate><enddate>20240401</enddate><creator>ElShennawy, Ethar M.</creator><creator>Hamed, Walaa M.</creator><creator>Samir, Sahar M.</creator><general>Springer Nature Singapore</general><general>Springer Nature B.V</general><scope>C6C</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0009-0001-2904-4555</orcidid></search><sort><creationdate>20240401</creationdate><title>Diagnostic accuracy of MRI–CBCT fused images in assessment of clinically diagnosed internal derangement of the temporomandibular joint</title><author>ElShennawy, Ethar M. ; Hamed, Walaa M. ; Samir, Sahar M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c426t-d08ef95a6f4ae4fc6296d549917b7b92c33a67366bff60fc968aa33730c05f123</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Cone-Beam Computed Tomography - methods</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Imaging</topic><topic>Magnetic resonance imaging</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Medicine</topic><topic>Oral and Maxillofacial Surgery</topic><topic>Original</topic><topic>Original Article</topic><topic>Radiology</topic><topic>Reproducibility of Results</topic><topic>Spiral Cone-Beam Computed Tomography</topic><topic>Statistical analysis</topic><topic>Temporomandibular joint</topic><topic>Temporomandibular Joint - diagnostic imaging</topic><topic>Temporomandibular Joint Disorders - diagnostic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ElShennawy, Ethar M.</creatorcontrib><creatorcontrib>Hamed, Walaa M.</creatorcontrib><creatorcontrib>Samir, Sahar M.</creatorcontrib><collection>SpringerOpen</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Oral radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ElShennawy, Ethar M.</au><au>Hamed, Walaa M.</au><au>Samir, Sahar M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diagnostic accuracy of MRI–CBCT fused images in assessment of clinically diagnosed internal derangement of the temporomandibular joint</atitle><jtitle>Oral radiology</jtitle><stitle>Oral Radiol</stitle><addtitle>Oral Radiol</addtitle><date>2024-04-01</date><risdate>2024</risdate><volume>40</volume><issue>2</issue><spage>226</spage><epage>233</epage><pages>226-233</pages><issn>0911-6028</issn><eissn>1613-9674</eissn><abstract>Objectives To evaluate the diagnostic accuracy of Fused (MRI)–CBCT images in the assessment of internal derangement of the temporomandibular joint. Methods MRI and CBCT images of the TMJ were evaluated bilaterally in 10 patients with clinically diagnosed internal derangement. Image fusion was performed using Amira 3D Software (version 5.4.3, Thermo Fisher Scientific Inc.). Results The AUC index for MRI–CBCT fused images was 0.83, which was significantly different from the null hypothesis value of 0.5. This was confirmed by inter-examiner reliability index of 0.87, which is statistically significant. Conclusion MRI–CBCT fused images can significantly improve the accuracy and inter-examiner reliability in the evaluation of clinically diagnosed cases with internal derangement.</abstract><cop>Singapore</cop><pub>Springer Nature Singapore</pub><pmid>38231306</pmid><doi>10.1007/s11282-023-00727-1</doi><tpages>8</tpages><orcidid>https://orcid.org/0009-0001-2904-4555</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0911-6028
ispartof Oral radiology, 2024-04, Vol.40 (2), p.226-233
issn 0911-6028
1613-9674
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10927775
source Springer Link
subjects Cone-Beam Computed Tomography - methods
Dentistry
Humans
Imaging
Magnetic resonance imaging
Magnetic Resonance Imaging - methods
Medicine
Oral and Maxillofacial Surgery
Original
Original Article
Radiology
Reproducibility of Results
Spiral Cone-Beam Computed Tomography
Statistical analysis
Temporomandibular joint
Temporomandibular Joint - diagnostic imaging
Temporomandibular Joint Disorders - diagnostic imaging
title Diagnostic accuracy of MRI–CBCT fused images in assessment of clinically diagnosed internal derangement of the temporomandibular joint
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T14%3A03%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diagnostic%20accuracy%20of%20MRI%E2%80%93CBCT%20fused%20images%20in%20assessment%20of%20clinically%20diagnosed%20internal%20derangement%20of%20the%20temporomandibular%20joint&rft.jtitle=Oral%20radiology&rft.au=ElShennawy,%20Ethar%20M.&rft.date=2024-04-01&rft.volume=40&rft.issue=2&rft.spage=226&rft.epage=233&rft.pages=226-233&rft.issn=0911-6028&rft.eissn=1613-9674&rft_id=info:doi/10.1007/s11282-023-00727-1&rft_dat=%3Cproquest_pubme%3E2915989029%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c426t-d08ef95a6f4ae4fc6296d549917b7b92c33a67366bff60fc968aa33730c05f123%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2955344299&rft_id=info:pmid/38231306&rfr_iscdi=true