Lung ultrasound in a nutshell. Lines, signs, some applications, and misconceptions from a radiologist's point of view. Part 2
In recent years, lung ultrasound (LUS) has developed rapidly, and it is gaining growing popularity in various scenarios. There are constant attempts to introduce it to new fields. In addition, knowledge regarding lung and LUS has been augmented by the recent COVID-19 pandemics. In the first part of...
Saved in:
Published in: | Polish journal of radiology 2024, Vol.89, p.e211-224 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c278t-7f67685cebd52db1c1a5f2d7c72aa3c5c9f6199fadacca236452861dc28d43ec3 |
container_end_page | 224 |
container_issue | |
container_start_page | e211 |
container_title | Polish journal of radiology |
container_volume | 89 |
creator | Łyźniak, Piotr Świętoń, Dominik Szurowska, Edyta |
description | In recent years, lung ultrasound (LUS) has developed rapidly, and it is gaining growing popularity in various scenarios. There are constant attempts to introduce it to new fields. In addition, knowledge regarding lung and LUS has been augmented by the recent COVID-19 pandemics. In the first part of this review we discuss lines, signs and pheno-mena, profiles, some applications, and misconceptions. An aim of the second part of the review is mainly to discuss some advanced applications of LUS, including lung elastography, lung spectroscopy, colour and spectral Doppler, contrast-enhanced ultrasound of lung, speckled tracking of pleura, quantification of pulmonary oedema, predicting success of talc pleurodesis, asthma exacerbations, detecting chest wall invasion by tumours, lung biopsy, estimating pleural effusion volume, and predicting mechanical ventilatory weaning outcome. For this purpose, we reviewed literature concerning LUS. |
doi_str_mv | 10.5114/pjr.2024.139286 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11112417</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3060379188</sourcerecordid><originalsourceid>FETCH-LOGICAL-c278t-7f67685cebd52db1c1a5f2d7c72aa3c5c9f6199fadacca236452861dc28d43ec3</originalsourceid><addsrcrecordid>eNpVUU1P3DAUtFBRQQvn3pBv9EBCbCexfaqqFf2QVoIDlXqz3trOYpTYwU6oeuh_x2Epgnd51vO8sWcGoU-kKhtC6svxPpa0onVJmKSiPUDHREhZVLLlH_KZM1YQVv8-Qqcp3Ve5WsLauv6IjpjggslKHqN_m9nv8NxPEVKYvcHOY8B-ntKd7fsSb5y36QInt_NLC4PFMI690zC5sIwg7wwu6eC1HZ9nuIthyCQRjAt92Lk0nSc8BucnHDr86OyfEt9AnDA9QYcd9MmevvQV-vXt6nb9o9hcf_-5_ropNOViKnjX8lY02m5NQ82WaAJNRw3XnAIw3WjZtUTKDgxoDTSLbLIfxGgqTM2sZiv0Zc87ztvBGm191turMboB4l8VwKn3N97dqV14VCQXrbOVK_T5hSGGh9mmSS2is0XgbZiTYlVbMS6JEBl6uYfqGFKKtnt9h1RqCU7l4NQSnNoHlzfO3n7vFf8_JvYERU-XLA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3060379188</pqid></control><display><type>article</type><title>Lung ultrasound in a nutshell. Lines, signs, some applications, and misconceptions from a radiologist's point of view. Part 2</title><source>PubMed Central</source><creator>Łyźniak, Piotr ; Świętoń, Dominik ; Szurowska, Edyta</creator><creatorcontrib>Łyźniak, Piotr ; Świętoń, Dominik ; Szurowska, Edyta</creatorcontrib><description>In recent years, lung ultrasound (LUS) has developed rapidly, and it is gaining growing popularity in various scenarios. There are constant attempts to introduce it to new fields. In addition, knowledge regarding lung and LUS has been augmented by the recent COVID-19 pandemics. In the first part of this review we discuss lines, signs and pheno-mena, profiles, some applications, and misconceptions. An aim of the second part of the review is mainly to discuss some advanced applications of LUS, including lung elastography, lung spectroscopy, colour and spectral Doppler, contrast-enhanced ultrasound of lung, speckled tracking of pleura, quantification of pulmonary oedema, predicting success of talc pleurodesis, asthma exacerbations, detecting chest wall invasion by tumours, lung biopsy, estimating pleural effusion volume, and predicting mechanical ventilatory weaning outcome. For this purpose, we reviewed literature concerning LUS.</description><identifier>ISSN: 1733-134X</identifier><identifier>ISSN: 1899-0967</identifier><identifier>EISSN: 1899-0967</identifier><identifier>DOI: 10.5114/pjr.2024.139286</identifier><identifier>PMID: 38783909</identifier><language>eng</language><publisher>Poland: Termedia Publishing House</publisher><subject>Review Paper</subject><ispartof>Polish journal of radiology, 2024, Vol.89, p.e211-224</ispartof><rights>Pol J Radiol 2024.</rights><rights>Pol J Radiol 2024 2024</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c278t-7f67685cebd52db1c1a5f2d7c72aa3c5c9f6199fadacca236452861dc28d43ec3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11112417/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11112417/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,4024,27923,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38783909$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Łyźniak, Piotr</creatorcontrib><creatorcontrib>Świętoń, Dominik</creatorcontrib><creatorcontrib>Szurowska, Edyta</creatorcontrib><title>Lung ultrasound in a nutshell. Lines, signs, some applications, and misconceptions from a radiologist's point of view. Part 2</title><title>Polish journal of radiology</title><addtitle>Pol J Radiol</addtitle><description>In recent years, lung ultrasound (LUS) has developed rapidly, and it is gaining growing popularity in various scenarios. There are constant attempts to introduce it to new fields. In addition, knowledge regarding lung and LUS has been augmented by the recent COVID-19 pandemics. In the first part of this review we discuss lines, signs and pheno-mena, profiles, some applications, and misconceptions. An aim of the second part of the review is mainly to discuss some advanced applications of LUS, including lung elastography, lung spectroscopy, colour and spectral Doppler, contrast-enhanced ultrasound of lung, speckled tracking of pleura, quantification of pulmonary oedema, predicting success of talc pleurodesis, asthma exacerbations, detecting chest wall invasion by tumours, lung biopsy, estimating pleural effusion volume, and predicting mechanical ventilatory weaning outcome. For this purpose, we reviewed literature concerning LUS.</description><subject>Review Paper</subject><issn>1733-134X</issn><issn>1899-0967</issn><issn>1899-0967</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpVUU1P3DAUtFBRQQvn3pBv9EBCbCexfaqqFf2QVoIDlXqz3trOYpTYwU6oeuh_x2Epgnd51vO8sWcGoU-kKhtC6svxPpa0onVJmKSiPUDHREhZVLLlH_KZM1YQVv8-Qqcp3Ve5WsLauv6IjpjggslKHqN_m9nv8NxPEVKYvcHOY8B-ntKd7fsSb5y36QInt_NLC4PFMI690zC5sIwg7wwu6eC1HZ9nuIthyCQRjAt92Lk0nSc8BucnHDr86OyfEt9AnDA9QYcd9MmevvQV-vXt6nb9o9hcf_-5_ropNOViKnjX8lY02m5NQ82WaAJNRw3XnAIw3WjZtUTKDgxoDTSLbLIfxGgqTM2sZiv0Zc87ztvBGm191turMboB4l8VwKn3N97dqV14VCQXrbOVK_T5hSGGh9mmSS2is0XgbZiTYlVbMS6JEBl6uYfqGFKKtnt9h1RqCU7l4NQSnNoHlzfO3n7vFf8_JvYERU-XLA</recordid><startdate>2024</startdate><enddate>2024</enddate><creator>Łyźniak, Piotr</creator><creator>Świętoń, Dominik</creator><creator>Szurowska, Edyta</creator><general>Termedia Publishing House</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>2024</creationdate><title>Lung ultrasound in a nutshell. Lines, signs, some applications, and misconceptions from a radiologist's point of view. Part 2</title><author>Łyźniak, Piotr ; Świętoń, Dominik ; Szurowska, Edyta</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c278t-7f67685cebd52db1c1a5f2d7c72aa3c5c9f6199fadacca236452861dc28d43ec3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Review Paper</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Łyźniak, Piotr</creatorcontrib><creatorcontrib>Świętoń, Dominik</creatorcontrib><creatorcontrib>Szurowska, Edyta</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Polish journal of radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Łyźniak, Piotr</au><au>Świętoń, Dominik</au><au>Szurowska, Edyta</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Lung ultrasound in a nutshell. Lines, signs, some applications, and misconceptions from a radiologist's point of view. Part 2</atitle><jtitle>Polish journal of radiology</jtitle><addtitle>Pol J Radiol</addtitle><date>2024</date><risdate>2024</risdate><volume>89</volume><spage>e211</spage><epage>224</epage><pages>e211-224</pages><issn>1733-134X</issn><issn>1899-0967</issn><eissn>1899-0967</eissn><abstract>In recent years, lung ultrasound (LUS) has developed rapidly, and it is gaining growing popularity in various scenarios. There are constant attempts to introduce it to new fields. In addition, knowledge regarding lung and LUS has been augmented by the recent COVID-19 pandemics. In the first part of this review we discuss lines, signs and pheno-mena, profiles, some applications, and misconceptions. An aim of the second part of the review is mainly to discuss some advanced applications of LUS, including lung elastography, lung spectroscopy, colour and spectral Doppler, contrast-enhanced ultrasound of lung, speckled tracking of pleura, quantification of pulmonary oedema, predicting success of talc pleurodesis, asthma exacerbations, detecting chest wall invasion by tumours, lung biopsy, estimating pleural effusion volume, and predicting mechanical ventilatory weaning outcome. For this purpose, we reviewed literature concerning LUS.</abstract><cop>Poland</cop><pub>Termedia Publishing House</pub><pmid>38783909</pmid><doi>10.5114/pjr.2024.139286</doi><tpages>14</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1733-134X |
ispartof | Polish journal of radiology, 2024, Vol.89, p.e211-224 |
issn | 1733-134X 1899-0967 1899-0967 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11112417 |
source | PubMed Central |
subjects | Review Paper |
title | Lung ultrasound in a nutshell. Lines, signs, some applications, and misconceptions from a radiologist's point of view. Part 2 |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T15%3A21%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Lung%20ultrasound%20in%20a%20nutshell.%20Lines,%20signs,%20some%20applications,%20and%20misconceptions%20from%20a%20radiologist's%20point%20of%20view.%20Part%202&rft.jtitle=Polish%20journal%20of%20radiology&rft.au=%C5%81y%C5%BAniak,%20Piotr&rft.date=2024&rft.volume=89&rft.spage=e211&rft.epage=224&rft.pages=e211-224&rft.issn=1733-134X&rft.eissn=1899-0967&rft_id=info:doi/10.5114/pjr.2024.139286&rft_dat=%3Cproquest_pubme%3E3060379188%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c278t-7f67685cebd52db1c1a5f2d7c72aa3c5c9f6199fadacca236452861dc28d43ec3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3060379188&rft_id=info:pmid/38783909&rfr_iscdi=true |