Loading…

Assessing the Efficacy of RADPAD Protection Drape in Reducing Radiation Exposure to Operators in the Cardiac Catheterization Laboratory: A Systematic Review and Meta-Analysis

One of the leading environmental hazards, ionizing radiation, is linked to several detrimental health consequences in the body. RADPAD (Worldwide Innovations & Technologies, Inc., Kansas City, Kansas) is a sterile, lead-free, lightweight, disposable radiation protection shield. We conducted a sy...

Full description

Saved in:
Bibliographic Details
Published in:Curēus (Palo Alto, CA) CA), 2024-04, Vol.16 (4), p.e59215-e59215
Main Authors: Bahar, Abdul Rasheed, Khanal, Resha, Hamza, Mohammad, Goru, Rohit K, Shafiq, Aimen, Haider, Mobeen Z, Basit, Salman Abdul, Bahar, Yasemin, Umer, Ahmed Muaaz, Sattar, Yasar, Alraies, M Chadi
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:One of the leading environmental hazards, ionizing radiation, is linked to several detrimental health consequences in the body. RADPAD (Worldwide Innovations & Technologies, Inc., Kansas City, Kansas) is a sterile, lead-free, lightweight, disposable radiation protection shield. We conducted a systematic review and meta-analysis to determine the effectiveness of RADPAD protection drapes in the cardiac catheterization lab and how they can aid interventional cardiologists in becoming subjected to less scatter radiation. PubMed, Embase, and Google Scholar were searched for studies discussing the efficacy of RADPAD protection drapes in reducing radiation exposure to operators in the cardiac catheterization laboratory. A random-effects model was used to pool odds ratios (ORs) and 95% confidence intervals (CIs) for endpoints: primary operator exposure dose, dose area product (DAP), relative exposure, and screening time. Our analysis included 892 patients from six studies. Compared to the No-RADPAD group, primary operator exposure dose (E) was significantly lower in the RADPAD group (OR: -0.9, 95% CI: -1.36 to -0.43, I = 80.5%, p = 0.0001). DAP was comparable between both groups (OR: 0.008, 95% CI: -0.12 to -0.14, I = 0%, p = 0.9066). There was no difference in the relative exposure (E/DAP) (OR: -0.47, 95% CI: -0.96 to 0.02, I = 0%, p = 0.90) and screening time (OR: 0.13, 95% CI: 0.08 to 0.35, I = 0%, p = 0.22) between the two groups. The interventional cardiology laboratory is exposed to significantly less scatter radiation during procedures owing to the RADPAD protective drape. Consequently, all catheterization laboratories could be advised to employ RADPAD protective drapes.
ISSN:2168-8184
2168-8184
DOI:10.7759/cureus.59215