Loading…
NFC Smartphone-Based Electrochemical Microfluidic Device Integrated with Nanobody Recognition for C‑Reactive Protein
Point-of-care testing (POCT) devices play a crucial role as tools for disease diagnostics, and the integration of biorecognition elements with electronic components into these devices widens their functionalities and facilitates the development of complex quantitative assays. Unfortunately, biosenso...
Saved in:
Published in: | ACS sensors 2024-06, Vol.9 (6), p.3066-3074 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-a323t-61e24fab8f71fb0cdb29674f0b0873bc1be1d1aded4653ae660c6b0f7f202efb3 |
container_end_page | 3074 |
container_issue | 6 |
container_start_page | 3066 |
container_title | ACS sensors |
container_volume | 9 |
creator | Boonkaew, Suchanat Szot-Karpińska, Katarzyna Niedziółka-Jönsson, Joanna de Marco, Ario Jönsson-Niedziółka, Martin |
description | Point-of-care testing (POCT) devices play a crucial role as tools for disease diagnostics, and the integration of biorecognition elements with electronic components into these devices widens their functionalities and facilitates the development of complex quantitative assays. Unfortunately, biosensors that exploit large conventional IgG antibodies to capture relevant biomarkers are often limited in terms of sensitivity, selectivity, and storage stability, considerably restricting the use of POCT in real-world applications. Therefore, we used nanobodies as they are more suitable for fabricating electrochemical biosensors with near-field communication (NFC) technology. Moreover, a flow-through microfluidic device was implemented in this system for the detection of C-reactive protein (CRP), an inflammation biomarker, and a model analyte. The resulting sensors not only have high sensitivity and portability but also retain automated sequential flow properties through capillary transport without the need for an external pump. We also compared the accuracy of CRP quantitative analyses between commercial PalmSens4 and NFC-based potentiostats. Furthermore, the sensor reliability was evaluated using three biological samples (artificial serum, plasma, and whole blood without any pretreatment). This platform will streamline the development of POCT devices by combining operational simplicity, low cost, fast analysis, and portability. |
doi_str_mv | 10.1021/acssensors.4c00249 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11217940</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3068751613</sourcerecordid><originalsourceid>FETCH-LOGICAL-a323t-61e24fab8f71fb0cdb29674f0b0873bc1be1d1aded4653ae660c6b0f7f202efb3</originalsourceid><addsrcrecordid>eNp9kc1uEzEUhS1ERau2L8ACeclmgn8m9swKQWhLpVJQgbVle64TVxM72J6g7voKvCJPglFCKRtW19L9zrF9DkLPKZlRwugrbXOGkGPKs9YSwtr-CTpiXPYNF3379NH5EJ3mfEsIoXPB5h15hg5510nZ990R2l6fL_DntU5ls4oBmrc6w4DPRrAlRbuCtbd6xB-8TdGNkx-8xe9g6y3gy1BgmXSp-HdfVvhah2jicIdvwMZl8MXHgF1MePHz_scNaFv8FvCnFAv4cIIOnB4znO7nMfp6fvZl8b65-nhxuXhz1WjOeGkEBdY6bTonqTPEDob1QraOGNJJbiw1QAeqBxhaMecahCBWGOKkY4SBM_wYvd75biazhsFCKEmPapN8_fKditqrfzfBr9QybhWljMq-JdXh5d4hxW8T5KLWPlsYRx0gTllxIjo5p4LyirIdWsPKOYF7uIcS9bs09bc0tS-til48fuGD5E9FFZjtgCpWt3FKoQb2P8dfK_yqWA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3068751613</pqid></control><display><type>article</type><title>NFC Smartphone-Based Electrochemical Microfluidic Device Integrated with Nanobody Recognition for C‑Reactive Protein</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)</source><creator>Boonkaew, Suchanat ; Szot-Karpińska, Katarzyna ; Niedziółka-Jönsson, Joanna ; de Marco, Ario ; Jönsson-Niedziółka, Martin</creator><creatorcontrib>Boonkaew, Suchanat ; Szot-Karpińska, Katarzyna ; Niedziółka-Jönsson, Joanna ; de Marco, Ario ; Jönsson-Niedziółka, Martin</creatorcontrib><description>Point-of-care testing (POCT) devices play a crucial role as tools for disease diagnostics, and the integration of biorecognition elements with electronic components into these devices widens their functionalities and facilitates the development of complex quantitative assays. Unfortunately, biosensors that exploit large conventional IgG antibodies to capture relevant biomarkers are often limited in terms of sensitivity, selectivity, and storage stability, considerably restricting the use of POCT in real-world applications. Therefore, we used nanobodies as they are more suitable for fabricating electrochemical biosensors with near-field communication (NFC) technology. Moreover, a flow-through microfluidic device was implemented in this system for the detection of C-reactive protein (CRP), an inflammation biomarker, and a model analyte. The resulting sensors not only have high sensitivity and portability but also retain automated sequential flow properties through capillary transport without the need for an external pump. We also compared the accuracy of CRP quantitative analyses between commercial PalmSens4 and NFC-based potentiostats. Furthermore, the sensor reliability was evaluated using three biological samples (artificial serum, plasma, and whole blood without any pretreatment). This platform will streamline the development of POCT devices by combining operational simplicity, low cost, fast analysis, and portability.</description><identifier>ISSN: 2379-3694</identifier><identifier>EISSN: 2379-3694</identifier><identifier>DOI: 10.1021/acssensors.4c00249</identifier><identifier>PMID: 38877998</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><ispartof>ACS sensors, 2024-06, Vol.9 (6), p.3066-3074</ispartof><rights>2024 The Authors. Published by American Chemical Society</rights><rights>2024 The Authors. Published by American Chemical Society 2024 The Authors</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-a323t-61e24fab8f71fb0cdb29674f0b0873bc1be1d1aded4653ae660c6b0f7f202efb3</cites><orcidid>0000-0001-5642-5946 ; 0000-0001-7729-819X ; 0000-0003-3582-941X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38877998$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Boonkaew, Suchanat</creatorcontrib><creatorcontrib>Szot-Karpińska, Katarzyna</creatorcontrib><creatorcontrib>Niedziółka-Jönsson, Joanna</creatorcontrib><creatorcontrib>de Marco, Ario</creatorcontrib><creatorcontrib>Jönsson-Niedziółka, Martin</creatorcontrib><title>NFC Smartphone-Based Electrochemical Microfluidic Device Integrated with Nanobody Recognition for C‑Reactive Protein</title><title>ACS sensors</title><addtitle>ACS Sens</addtitle><description>Point-of-care testing (POCT) devices play a crucial role as tools for disease diagnostics, and the integration of biorecognition elements with electronic components into these devices widens their functionalities and facilitates the development of complex quantitative assays. Unfortunately, biosensors that exploit large conventional IgG antibodies to capture relevant biomarkers are often limited in terms of sensitivity, selectivity, and storage stability, considerably restricting the use of POCT in real-world applications. Therefore, we used nanobodies as they are more suitable for fabricating electrochemical biosensors with near-field communication (NFC) technology. Moreover, a flow-through microfluidic device was implemented in this system for the detection of C-reactive protein (CRP), an inflammation biomarker, and a model analyte. The resulting sensors not only have high sensitivity and portability but also retain automated sequential flow properties through capillary transport without the need for an external pump. We also compared the accuracy of CRP quantitative analyses between commercial PalmSens4 and NFC-based potentiostats. Furthermore, the sensor reliability was evaluated using three biological samples (artificial serum, plasma, and whole blood without any pretreatment). This platform will streamline the development of POCT devices by combining operational simplicity, low cost, fast analysis, and portability.</description><issn>2379-3694</issn><issn>2379-3694</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kc1uEzEUhS1ERau2L8ACeclmgn8m9swKQWhLpVJQgbVle64TVxM72J6g7voKvCJPglFCKRtW19L9zrF9DkLPKZlRwugrbXOGkGPKs9YSwtr-CTpiXPYNF3379NH5EJ3mfEsIoXPB5h15hg5510nZ990R2l6fL_DntU5ls4oBmrc6w4DPRrAlRbuCtbd6xB-8TdGNkx-8xe9g6y3gy1BgmXSp-HdfVvhah2jicIdvwMZl8MXHgF1MePHz_scNaFv8FvCnFAv4cIIOnB4znO7nMfp6fvZl8b65-nhxuXhz1WjOeGkEBdY6bTonqTPEDob1QraOGNJJbiw1QAeqBxhaMecahCBWGOKkY4SBM_wYvd75biazhsFCKEmPapN8_fKditqrfzfBr9QybhWljMq-JdXh5d4hxW8T5KLWPlsYRx0gTllxIjo5p4LyirIdWsPKOYF7uIcS9bs09bc0tS-til48fuGD5E9FFZjtgCpWt3FKoQb2P8dfK_yqWA</recordid><startdate>20240628</startdate><enddate>20240628</enddate><creator>Boonkaew, Suchanat</creator><creator>Szot-Karpińska, Katarzyna</creator><creator>Niedziółka-Jönsson, Joanna</creator><creator>de Marco, Ario</creator><creator>Jönsson-Niedziółka, Martin</creator><general>American Chemical Society</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0001-5642-5946</orcidid><orcidid>https://orcid.org/0000-0001-7729-819X</orcidid><orcidid>https://orcid.org/0000-0003-3582-941X</orcidid></search><sort><creationdate>20240628</creationdate><title>NFC Smartphone-Based Electrochemical Microfluidic Device Integrated with Nanobody Recognition for C‑Reactive Protein</title><author>Boonkaew, Suchanat ; Szot-Karpińska, Katarzyna ; Niedziółka-Jönsson, Joanna ; de Marco, Ario ; Jönsson-Niedziółka, Martin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a323t-61e24fab8f71fb0cdb29674f0b0873bc1be1d1aded4653ae660c6b0f7f202efb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Boonkaew, Suchanat</creatorcontrib><creatorcontrib>Szot-Karpińska, Katarzyna</creatorcontrib><creatorcontrib>Niedziółka-Jönsson, Joanna</creatorcontrib><creatorcontrib>de Marco, Ario</creatorcontrib><creatorcontrib>Jönsson-Niedziółka, Martin</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>ACS sensors</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Boonkaew, Suchanat</au><au>Szot-Karpińska, Katarzyna</au><au>Niedziółka-Jönsson, Joanna</au><au>de Marco, Ario</au><au>Jönsson-Niedziółka, Martin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>NFC Smartphone-Based Electrochemical Microfluidic Device Integrated with Nanobody Recognition for C‑Reactive Protein</atitle><jtitle>ACS sensors</jtitle><addtitle>ACS Sens</addtitle><date>2024-06-28</date><risdate>2024</risdate><volume>9</volume><issue>6</issue><spage>3066</spage><epage>3074</epage><pages>3066-3074</pages><issn>2379-3694</issn><eissn>2379-3694</eissn><abstract>Point-of-care testing (POCT) devices play a crucial role as tools for disease diagnostics, and the integration of biorecognition elements with electronic components into these devices widens their functionalities and facilitates the development of complex quantitative assays. Unfortunately, biosensors that exploit large conventional IgG antibodies to capture relevant biomarkers are often limited in terms of sensitivity, selectivity, and storage stability, considerably restricting the use of POCT in real-world applications. Therefore, we used nanobodies as they are more suitable for fabricating electrochemical biosensors with near-field communication (NFC) technology. Moreover, a flow-through microfluidic device was implemented in this system for the detection of C-reactive protein (CRP), an inflammation biomarker, and a model analyte. The resulting sensors not only have high sensitivity and portability but also retain automated sequential flow properties through capillary transport without the need for an external pump. We also compared the accuracy of CRP quantitative analyses between commercial PalmSens4 and NFC-based potentiostats. Furthermore, the sensor reliability was evaluated using three biological samples (artificial serum, plasma, and whole blood without any pretreatment). This platform will streamline the development of POCT devices by combining operational simplicity, low cost, fast analysis, and portability.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>38877998</pmid><doi>10.1021/acssensors.4c00249</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0001-5642-5946</orcidid><orcidid>https://orcid.org/0000-0001-7729-819X</orcidid><orcidid>https://orcid.org/0000-0003-3582-941X</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2379-3694 |
ispartof | ACS sensors, 2024-06, Vol.9 (6), p.3066-3074 |
issn | 2379-3694 2379-3694 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11217940 |
source | American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list) |
title | NFC Smartphone-Based Electrochemical Microfluidic Device Integrated with Nanobody Recognition for C‑Reactive Protein |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T02%3A03%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=NFC%20Smartphone-Based%20Electrochemical%20Microfluidic%20Device%20Integrated%20with%20Nanobody%20Recognition%20for%20C%E2%80%91Reactive%20Protein&rft.jtitle=ACS%20sensors&rft.au=Boonkaew,%20Suchanat&rft.date=2024-06-28&rft.volume=9&rft.issue=6&rft.spage=3066&rft.epage=3074&rft.pages=3066-3074&rft.issn=2379-3694&rft.eissn=2379-3694&rft_id=info:doi/10.1021/acssensors.4c00249&rft_dat=%3Cproquest_pubme%3E3068751613%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a323t-61e24fab8f71fb0cdb29674f0b0873bc1be1d1aded4653ae660c6b0f7f202efb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3068751613&rft_id=info:pmid/38877998&rfr_iscdi=true |