Loading…
Self-swabbing versus assisted swabbing for viral detection by qRT-PCR: the experience from SARS-CoV-2 based on a meta-analysis of six prospectively designed evaluations conducted in a UK setting
Purpose In April 2020, the UK Government implemented NHS Test and Trace to provide SARS-CoV-2 quantitative reverse transcription polymerase chain reaction (qRT-PCR) testing for the public, with nose-and-throat swabbing for samples performed by trained staff. Self-swabbing (SS) would allow rapid scal...
Saved in:
Published in: | European journal of clinical microbiology & infectious diseases 2024-08, Vol.43 (8), p.1621-1630 |
---|---|
Main Authors: | , , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
In April 2020, the UK Government implemented NHS Test and Trace to provide SARS-CoV-2 quantitative reverse transcription polymerase chain reaction (qRT-PCR) testing for the public, with nose-and-throat swabbing for samples performed by trained staff. Self-swabbing (SS) would allow rapid scale-up of testing capacity and access. Six studies were undertaken to determine whether SS was as effective for detecting SARS-CoV-2 as swabbing performed by trained staff.
Methods
Six prospective studies were conducted between April–October 2020, using six swab/media combinations. Differences between assisted swabbing (AS) and SS were evaluated for concordance, positivity, sensitivity, cycle threshold (Ct) values and void rates. Statistical analysis was performed using 95% confidence intervals (CIs), paired t-tests and model-based methods.
Results
Overall, 3,253 individuals were recruited (median age 37 years, 49% female), with 2,933 having valid paired qRT-PCR results. Pooled concordance rate was 98% (95% CI: 96%, 99%). Positivity rate differences for SS (8.1%) and AS (8.4%) and differences in pooled sensitivities between SS (86%; 95% CI: 78%, 92%) and AS (91%; 95% CI: 78%, 96%) were nonsignificant. Both types of swabbing led to pooled void rates below 2% and strongly correlated Ct values. Age, sex and previous swabbing experience did not have a significant impact on concordance or sensitivity.
Conclusion
The UK adopted a policy to promote self-testing for SARS-CoV-2 based on data demonstrating equivalence of SS versus AS. Positive outcomes with SS are likely generalisable to testing for other respiratory pathogens, and we consider self-sampling and self-testing essential for future pandemic preparedness. |
---|---|
ISSN: | 0934-9723 1435-4373 1435-4373 |
DOI: | 10.1007/s10096-024-04866-z |