Loading…
Sparing the Hippocampus in Prophylactic Cranial Irradiation Using Three Different Linear Accelerators: A Comparative Study
Hippocampus protection, as an organ at risk in brain radiotherapy, might protect patients' quality of life. Prophylactic cranial irradiation (PCI) has been used traditionally in small cell lung cancer (SCLC) patients as it increases survival. This study aimed to discover the contributing parame...
Saved in:
Published in: | Curēus (Palo Alto, CA) CA), 2024-06, Vol.16 (6), p.e63137 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Hippocampus protection, as an organ at risk in brain radiotherapy, might protect patients' quality of life. Prophylactic cranial irradiation (PCI) has been used traditionally in small cell lung cancer (SCLC) patients as it increases survival. This study aimed to discover the contributing parameters for a successful PCI with simultaneous protection of the hippocampus by using three different treatment machines. For this purpose, treatment plans were generated for 45 SCLC patients using three half-arcs in three linear accelerators (LINACs; Elekta Infinity, Synergy, and Axesse; Elekta Ltd, Stockholm, Sweden) with different radiation field sizes and multileaf collimator (MLC) leaf thickness characteristics. The prescribed dose was 25 Gy in 10 fractions. Thresholds for the hippocampus were calculated based on the Radiation Therapy Oncology Group 0933 dose constraints. The planning and treatment system templates were common to all three LINACs. Plan evaluation was based on the dosimetric target coverage by the 95% isodose, the maximum dose of the plan, the conformity index (CI), the degree of plan modulation (MOD), and the patient-specific quality assurance (QA) pass rate. The mean target coverage was highest for Infinity (97.3%), followed by Axesse (96.6%) and Synergy (95.5%). The mean maximum dose was higher for Synergy (27.5 Gy), followed by Infinity (27.0 Gy) and Axesse (26.9 Gy). Axesse plans had the highest CI (0.93), followed by Infinity (0.91) and Synergy (0.88). Plan MOD was lower for Synergy (2.88) compared with Infinity (3.07) and Axesse (3.69). Finally, patient-specific QA was successful in all Infinity plans, in all but one Synergy plan, and in 17/45 Axesse plans, as was expected from the field size in that treatment unit. Based on overall performance, the most favorable combination of target coverage, hippocampus sparing, and plan deliverability was obtained with the LINAC, which has the largest field opening and thinnest MLC leaves. |
---|---|
ISSN: | 2168-8184 2168-8184 |
DOI: | 10.7759/cureus.63137 |