Loading…
Comparative evaluations of shear bond strength of mineral trioxide aggregate, Biodentine, and calcium-enriched mixture to bulk-fill flowable composite using three different adhesive systems: An in vitro study
The objective of the study was to assess the shear bond strength of bulk-fill flowable composite resin smart dentin replacement plus when bonded to mineral trioxide aggregate (MTA)-angelus, biodentine, and calcium-enriched mixture (CEM) at two different aging periods (15 min and 72 h) using three di...
Saved in:
Published in: | Journal of conservative dentistry 2024-07, Vol.27 (7), p.706-713 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c2232-b37cab73be2006d5eb2d9a05b00590c4d2e7ede16a9d05f52588ea5ccab6c9913 |
container_end_page | 713 |
container_issue | 7 |
container_start_page | 706 |
container_title | Journal of conservative dentistry |
container_volume | 27 |
creator | Fatima, Asmat İftekhar, Huma Alam, Sharique Tewari, Rajendra Kumar Andrabi, Mukhtar Un Nisar |
description | The objective of the study was to assess the shear bond strength of bulk-fill flowable composite resin smart dentin replacement plus when bonded to mineral trioxide aggregate (MTA)-angelus, biodentine, and calcium-enriched mixture (CEM) at two different aging periods (15 min and 72 h) using three distinct adhesive systems. In addition, the study identified the specific modes of failure (adhesive, cohesive, or mixed) using a stereomicroscope and scanning electron microscope.
One hundred and twenty-six cylindrical acrylic blocks used in the study were sorted into three groups based on the bioactive substance used to fill the 3-mm diameter and 3-mm high hole in the center of each block. The groups were MTA, Biodentine, and CEM. The specimens were then divided into subgroups based on the aging interval (15 min and 72 h) of the bioactive material and the adhesive system used (two-step total-etch, two-step self-etch [SE], and one-step SE) while bonding to the restorative bulk-fill flowable composite. The shear bond strength values were measured with a universal testing machine, and the data were analyzed using two-way and one-way analysis of variance, followed by a
test. The specimens were assessed under stereomicroscope and scanning electron microscope to characterize the mode of bond failure (cohesive, adhesive, or mixed).
The study showed that the type of adhesive system and the time of bonding affected the shear bond strength of bulk-fill composite to the pulp capping agents (
< 0.05). For MTA, the highest bond strength was observed with two-step SE group at 15 min (18.16 ± 2.97 MPa) (
< 0.05). CEM exhibited the highest bond strength with two-step SE group at 72 h intervals (8.77 ± 1.76) (
< 0.05). The highest bond strength for biodentine group was observed with total-etch group (8.54 ± 1.35 Mpa) and two-step SE (8.19 ± 1.94 Mpa) bonded at 72 h interval (
< 0.05). The majority of the samples in the MTA group (29/42) and CEM group (20/42) showed a cohesive fracture, whereas Biodentine group (22/42) had an adhesive fracture in most of its samples.
MTA demonstrated the highest bond strength with two-step SE group at 15 min, and CEM exhibited the highest bond strength with two-step SE groups at 72 h interval. For biodentine group, the type of adhesive used did not impact the bond strength values. |
doi_str_mv | 10.4103/JCDE.JCDE_192_24 |
format | article |
fullrecord | <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11385902</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A819755278</galeid><sourcerecordid>A819755278</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2232-b37cab73be2006d5eb2d9a05b00590c4d2e7ede16a9d05f52588ea5ccab6c9913</originalsourceid><addsrcrecordid>eNpVUk1v1DAQjRCIVqV3TsgnxKFZHCfZxFzQdilfqsQFzpZjTxKDYy-2s3T_JT-J2W5ZbWXJHtnvzTzPvCx7WdBFVdDy7df1h5vFfhMFZ4JVT7JzxmuaVw1tnx7jYnmWXcb4k1LKOKe8pc-zs5KzJas5Pc_-rv20kUEmswUCW2lnDL2LxPckjiAD6bzTJKYAbkjj_noyDoK0JAXj74wGIochwCATXJFr4zW4hIgrIpGnpFVmnnJwwagRNJLv0hyAJE-62f7Ke2Mt6a3_IzsLRKEYH00CMkfjBpLGAEC06XvA-olIPULcK427mGCK78jKEePI1qTgUeSsdy-yZ720ES4fzovsx8eb7-vP-e23T1_Wq9tcMVayvCsbJbum7IBRutQ1dExzSeuOUuyLqjSDBjQUS8k1rfua1W0LslZIWirOi_Iie3_Iu5m7CbRCedgUsQlmkmEnvDTi8Yszoxj8VhRF2WIJhhnePGQI_vcMMYnJRAXWSgd-jqLEIVcVb-oSoYsDdJAWhHG9x5QKl4bJKO8A2whi1RaIrlnTIuH1CQHnaNMYvZ3vZ_sYSA9AFXyMAfrjDwoq9jYT9w47sRlSXp3-_Ej4b6ryH0I01MA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3103449753</pqid></control><display><type>article</type><title>Comparative evaluations of shear bond strength of mineral trioxide aggregate, Biodentine, and calcium-enriched mixture to bulk-fill flowable composite using three different adhesive systems: An in vitro study</title><source>PubMed Central</source><creator>Fatima, Asmat ; İftekhar, Huma ; Alam, Sharique ; Tewari, Rajendra Kumar ; Andrabi, Mukhtar Un Nisar</creator><creatorcontrib>Fatima, Asmat ; İftekhar, Huma ; Alam, Sharique ; Tewari, Rajendra Kumar ; Andrabi, Mukhtar Un Nisar</creatorcontrib><description>The objective of the study was to assess the shear bond strength of bulk-fill flowable composite resin smart dentin replacement plus when bonded to mineral trioxide aggregate (MTA)-angelus, biodentine, and calcium-enriched mixture (CEM) at two different aging periods (15 min and 72 h) using three distinct adhesive systems. In addition, the study identified the specific modes of failure (adhesive, cohesive, or mixed) using a stereomicroscope and scanning electron microscope.
One hundred and twenty-six cylindrical acrylic blocks used in the study were sorted into three groups based on the bioactive substance used to fill the 3-mm diameter and 3-mm high hole in the center of each block. The groups were MTA, Biodentine, and CEM. The specimens were then divided into subgroups based on the aging interval (15 min and 72 h) of the bioactive material and the adhesive system used (two-step total-etch, two-step self-etch [SE], and one-step SE) while bonding to the restorative bulk-fill flowable composite. The shear bond strength values were measured with a universal testing machine, and the data were analyzed using two-way and one-way analysis of variance, followed by a
test. The specimens were assessed under stereomicroscope and scanning electron microscope to characterize the mode of bond failure (cohesive, adhesive, or mixed).
The study showed that the type of adhesive system and the time of bonding affected the shear bond strength of bulk-fill composite to the pulp capping agents (
< 0.05). For MTA, the highest bond strength was observed with two-step SE group at 15 min (18.16 ± 2.97 MPa) (
< 0.05). CEM exhibited the highest bond strength with two-step SE group at 72 h intervals (8.77 ± 1.76) (
< 0.05). The highest bond strength for biodentine group was observed with total-etch group (8.54 ± 1.35 Mpa) and two-step SE (8.19 ± 1.94 Mpa) bonded at 72 h interval (
< 0.05). The majority of the samples in the MTA group (29/42) and CEM group (20/42) showed a cohesive fracture, whereas Biodentine group (22/42) had an adhesive fracture in most of its samples.
MTA demonstrated the highest bond strength with two-step SE group at 15 min, and CEM exhibited the highest bond strength with two-step SE groups at 72 h interval. For biodentine group, the type of adhesive used did not impact the bond strength values.</description><identifier>ISSN: 2950-4716</identifier><identifier>ISSN: 0972-0707</identifier><identifier>ISSN: 2950-4708</identifier><identifier>EISSN: 2950-4708</identifier><identifier>DOI: 10.4103/JCDE.JCDE_192_24</identifier><identifier>PMID: 39262590</identifier><language>eng</language><publisher>India: Medknow Publications and Media Pvt. Ltd</publisher><subject>Adhesives ; Original ; Substance abuse</subject><ispartof>Journal of conservative dentistry, 2024-07, Vol.27 (7), p.706-713</ispartof><rights>Copyright: © 2024 Journal of Conservative Dentistry and Endodontics.</rights><rights>COPYRIGHT 2024 Medknow Publications and Media Pvt. Ltd.</rights><rights>Copyright: © 2024 Journal of Conservative Dentistry and Endodontics 2024</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2232-b37cab73be2006d5eb2d9a05b00590c4d2e7ede16a9d05f52588ea5ccab6c9913</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11385902/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11385902/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39262590$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fatima, Asmat</creatorcontrib><creatorcontrib>İftekhar, Huma</creatorcontrib><creatorcontrib>Alam, Sharique</creatorcontrib><creatorcontrib>Tewari, Rajendra Kumar</creatorcontrib><creatorcontrib>Andrabi, Mukhtar Un Nisar</creatorcontrib><title>Comparative evaluations of shear bond strength of mineral trioxide aggregate, Biodentine, and calcium-enriched mixture to bulk-fill flowable composite using three different adhesive systems: An in vitro study</title><title>Journal of conservative dentistry</title><addtitle>J Conserv Dent Endod</addtitle><description>The objective of the study was to assess the shear bond strength of bulk-fill flowable composite resin smart dentin replacement plus when bonded to mineral trioxide aggregate (MTA)-angelus, biodentine, and calcium-enriched mixture (CEM) at two different aging periods (15 min and 72 h) using three distinct adhesive systems. In addition, the study identified the specific modes of failure (adhesive, cohesive, or mixed) using a stereomicroscope and scanning electron microscope.
One hundred and twenty-six cylindrical acrylic blocks used in the study were sorted into three groups based on the bioactive substance used to fill the 3-mm diameter and 3-mm high hole in the center of each block. The groups were MTA, Biodentine, and CEM. The specimens were then divided into subgroups based on the aging interval (15 min and 72 h) of the bioactive material and the adhesive system used (two-step total-etch, two-step self-etch [SE], and one-step SE) while bonding to the restorative bulk-fill flowable composite. The shear bond strength values were measured with a universal testing machine, and the data were analyzed using two-way and one-way analysis of variance, followed by a
test. The specimens were assessed under stereomicroscope and scanning electron microscope to characterize the mode of bond failure (cohesive, adhesive, or mixed).
The study showed that the type of adhesive system and the time of bonding affected the shear bond strength of bulk-fill composite to the pulp capping agents (
< 0.05). For MTA, the highest bond strength was observed with two-step SE group at 15 min (18.16 ± 2.97 MPa) (
< 0.05). CEM exhibited the highest bond strength with two-step SE group at 72 h intervals (8.77 ± 1.76) (
< 0.05). The highest bond strength for biodentine group was observed with total-etch group (8.54 ± 1.35 Mpa) and two-step SE (8.19 ± 1.94 Mpa) bonded at 72 h interval (
< 0.05). The majority of the samples in the MTA group (29/42) and CEM group (20/42) showed a cohesive fracture, whereas Biodentine group (22/42) had an adhesive fracture in most of its samples.
MTA demonstrated the highest bond strength with two-step SE group at 15 min, and CEM exhibited the highest bond strength with two-step SE groups at 72 h interval. For biodentine group, the type of adhesive used did not impact the bond strength values.</description><subject>Adhesives</subject><subject>Original</subject><subject>Substance abuse</subject><issn>2950-4716</issn><issn>0972-0707</issn><issn>2950-4708</issn><issn>2950-4708</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpVUk1v1DAQjRCIVqV3TsgnxKFZHCfZxFzQdilfqsQFzpZjTxKDYy-2s3T_JT-J2W5ZbWXJHtnvzTzPvCx7WdBFVdDy7df1h5vFfhMFZ4JVT7JzxmuaVw1tnx7jYnmWXcb4k1LKOKe8pc-zs5KzJas5Pc_-rv20kUEmswUCW2lnDL2LxPckjiAD6bzTJKYAbkjj_noyDoK0JAXj74wGIochwCATXJFr4zW4hIgrIpGnpFVmnnJwwagRNJLv0hyAJE-62f7Ke2Mt6a3_IzsLRKEYH00CMkfjBpLGAEC06XvA-olIPULcK427mGCK78jKEePI1qTgUeSsdy-yZ720ES4fzovsx8eb7-vP-e23T1_Wq9tcMVayvCsbJbum7IBRutQ1dExzSeuOUuyLqjSDBjQUS8k1rfua1W0LslZIWirOi_Iie3_Iu5m7CbRCedgUsQlmkmEnvDTi8Yszoxj8VhRF2WIJhhnePGQI_vcMMYnJRAXWSgd-jqLEIVcVb-oSoYsDdJAWhHG9x5QKl4bJKO8A2whi1RaIrlnTIuH1CQHnaNMYvZ3vZ_sYSA9AFXyMAfrjDwoq9jYT9w47sRlSXp3-_Ej4b6ryH0I01MA</recordid><startdate>202407</startdate><enddate>202407</enddate><creator>Fatima, Asmat</creator><creator>İftekhar, Huma</creator><creator>Alam, Sharique</creator><creator>Tewari, Rajendra Kumar</creator><creator>Andrabi, Mukhtar Un Nisar</creator><general>Medknow Publications and Media Pvt. Ltd</general><general>Wolters Kluwer - Medknow</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>202407</creationdate><title>Comparative evaluations of shear bond strength of mineral trioxide aggregate, Biodentine, and calcium-enriched mixture to bulk-fill flowable composite using three different adhesive systems: An in vitro study</title><author>Fatima, Asmat ; İftekhar, Huma ; Alam, Sharique ; Tewari, Rajendra Kumar ; Andrabi, Mukhtar Un Nisar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2232-b37cab73be2006d5eb2d9a05b00590c4d2e7ede16a9d05f52588ea5ccab6c9913</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Adhesives</topic><topic>Original</topic><topic>Substance abuse</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fatima, Asmat</creatorcontrib><creatorcontrib>İftekhar, Huma</creatorcontrib><creatorcontrib>Alam, Sharique</creatorcontrib><creatorcontrib>Tewari, Rajendra Kumar</creatorcontrib><creatorcontrib>Andrabi, Mukhtar Un Nisar</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of conservative dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fatima, Asmat</au><au>İftekhar, Huma</au><au>Alam, Sharique</au><au>Tewari, Rajendra Kumar</au><au>Andrabi, Mukhtar Un Nisar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative evaluations of shear bond strength of mineral trioxide aggregate, Biodentine, and calcium-enriched mixture to bulk-fill flowable composite using three different adhesive systems: An in vitro study</atitle><jtitle>Journal of conservative dentistry</jtitle><addtitle>J Conserv Dent Endod</addtitle><date>2024-07</date><risdate>2024</risdate><volume>27</volume><issue>7</issue><spage>706</spage><epage>713</epage><pages>706-713</pages><issn>2950-4716</issn><issn>0972-0707</issn><issn>2950-4708</issn><eissn>2950-4708</eissn><abstract>The objective of the study was to assess the shear bond strength of bulk-fill flowable composite resin smart dentin replacement plus when bonded to mineral trioxide aggregate (MTA)-angelus, biodentine, and calcium-enriched mixture (CEM) at two different aging periods (15 min and 72 h) using three distinct adhesive systems. In addition, the study identified the specific modes of failure (adhesive, cohesive, or mixed) using a stereomicroscope and scanning electron microscope.
One hundred and twenty-six cylindrical acrylic blocks used in the study were sorted into three groups based on the bioactive substance used to fill the 3-mm diameter and 3-mm high hole in the center of each block. The groups were MTA, Biodentine, and CEM. The specimens were then divided into subgroups based on the aging interval (15 min and 72 h) of the bioactive material and the adhesive system used (two-step total-etch, two-step self-etch [SE], and one-step SE) while bonding to the restorative bulk-fill flowable composite. The shear bond strength values were measured with a universal testing machine, and the data were analyzed using two-way and one-way analysis of variance, followed by a
test. The specimens were assessed under stereomicroscope and scanning electron microscope to characterize the mode of bond failure (cohesive, adhesive, or mixed).
The study showed that the type of adhesive system and the time of bonding affected the shear bond strength of bulk-fill composite to the pulp capping agents (
< 0.05). For MTA, the highest bond strength was observed with two-step SE group at 15 min (18.16 ± 2.97 MPa) (
< 0.05). CEM exhibited the highest bond strength with two-step SE group at 72 h intervals (8.77 ± 1.76) (
< 0.05). The highest bond strength for biodentine group was observed with total-etch group (8.54 ± 1.35 Mpa) and two-step SE (8.19 ± 1.94 Mpa) bonded at 72 h interval (
< 0.05). The majority of the samples in the MTA group (29/42) and CEM group (20/42) showed a cohesive fracture, whereas Biodentine group (22/42) had an adhesive fracture in most of its samples.
MTA demonstrated the highest bond strength with two-step SE group at 15 min, and CEM exhibited the highest bond strength with two-step SE groups at 72 h interval. For biodentine group, the type of adhesive used did not impact the bond strength values.</abstract><cop>India</cop><pub>Medknow Publications and Media Pvt. Ltd</pub><pmid>39262590</pmid><doi>10.4103/JCDE.JCDE_192_24</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2950-4716 |
ispartof | Journal of conservative dentistry, 2024-07, Vol.27 (7), p.706-713 |
issn | 2950-4716 0972-0707 2950-4708 2950-4708 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11385902 |
source | PubMed Central |
subjects | Adhesives Original Substance abuse |
title | Comparative evaluations of shear bond strength of mineral trioxide aggregate, Biodentine, and calcium-enriched mixture to bulk-fill flowable composite using three different adhesive systems: An in vitro study |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T16%3A44%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20evaluations%20of%20shear%20bond%20strength%20of%20mineral%20trioxide%20aggregate,%20Biodentine,%20and%20calcium-enriched%20mixture%20to%20bulk-fill%20flowable%20composite%20using%20three%20different%20adhesive%20systems:%20An%20in%20vitro%20study&rft.jtitle=Journal%20of%20conservative%20dentistry&rft.au=Fatima,%20Asmat&rft.date=2024-07&rft.volume=27&rft.issue=7&rft.spage=706&rft.epage=713&rft.pages=706-713&rft.issn=2950-4716&rft.eissn=2950-4708&rft_id=info:doi/10.4103/JCDE.JCDE_192_24&rft_dat=%3Cgale_pubme%3EA819755278%3C/gale_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2232-b37cab73be2006d5eb2d9a05b00590c4d2e7ede16a9d05f52588ea5ccab6c9913%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3103449753&rft_id=info:pmid/39262590&rft_galeid=A819755278&rfr_iscdi=true |