Loading…

Comparison of two flow measurement devices for use in fire experiments

Bi-directional probes are utilized throughout fire science to measure fire-induced flows due to their ability to measure flow which changes direction, and to withstand hostile environments. However, they are not available commercially and researchers must take it upon themselves to make and manufact...

Full description

Saved in:
Bibliographic Details
Published in:Proceedings of the Combustion Institute 2024, Vol.40 (1-4), p.105557, Article 105557
Main Authors: Di Cristina, Giovanni, Bryant, Rodney A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c340t-60d537466f4f459a910f068e341c0f4032f06d530e7b5e2674c1fab834140e013
container_end_page
container_issue 1-4
container_start_page 105557
container_title Proceedings of the Combustion Institute
container_volume 40
creator Di Cristina, Giovanni
Bryant, Rodney A.
description Bi-directional probes are utilized throughout fire science to measure fire-induced flows due to their ability to measure flow which changes direction, and to withstand hostile environments. However, they are not available commercially and researchers must take it upon themselves to make and manufacture them. S-type pitot probes (S-probes) work on the same principle as bi-directional probes, measuring the differential pressure between two openings, thereby offering the same benefits. However, S-probes also feature reliable manufacturing and calibration standards. In this study, the performance of bi-directional and S-probes is characterized against pitot-static probes in two scenarios. First, measurements of a steady, smooth flow in a well-characterized wind tunnel are examined. Second, the probes are used to measure the velocity profile across a turbulent jet from a blower fan. In both scenarios, the S-probe performed comparable to or better than the bi-directional probe in terms of accuracy. It is found that S-probes have similar performance to bi-directional probes in well conditioned flows. In the turbulent jet flow measurements, S-probe measurements are within 2% of pitot-static measurements in the core region of the jet, while bi-directional probes are within 6%.
doi_str_mv 10.1016/j.proci.2024.105557
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11500316</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1540748924003651</els_id><sourcerecordid>3120597336</sourcerecordid><originalsourceid>FETCH-LOGICAL-c340t-60d537466f4f459a910f068e341c0f4032f06d530e7b5e2674c1fab834140e013</originalsourceid><addsrcrecordid>eNp9UctO5DAQtFaslucXICEfuWRox3Y8OSCERrwkpL3sni2P0waPkjjYyQB_j4cBxF72ZLu7uqpdRcgxgxkDVp2tZkMM1s9KKEWuSCnVD7LH5ooXpQKxk-9SQKHEvN4l-ymtALgCLn-RXV4LUdey3iPXi9ANJvoUehocHZ8DdW14ph2aNEXssB9pg2tvMVEXIp0SUt9T5yNSfBkw-g0kHZKfzrQJjz7OA_L3-urP4ra4_31zt7i8LywXMBYVNJIrUVVOOCFrUzNwUM2RC2bBCeBlfmYIoFpKLCslLHNmOc99AQiMH5CLLe8wLTtsbNaOptVDXsPEVx2M1_92ev-oH8JaMybz91mVGU4_GGJ4mjCNuvPJYtuaHsOUNGclyFpxvoHyLdTGkFJE96XDQG8i0Cv9HoHeRKC3EeSpk-8rfs18ep4B51sAZqPWHqNO1mNvscmm2lE3wf9X4A1Ly5i_</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3120597336</pqid></control><display><type>article</type><title>Comparison of two flow measurement devices for use in fire experiments</title><source>ScienceDirect Freedom Collection</source><creator>Di Cristina, Giovanni ; Bryant, Rodney A.</creator><creatorcontrib>Di Cristina, Giovanni ; Bryant, Rodney A.</creatorcontrib><description>Bi-directional probes are utilized throughout fire science to measure fire-induced flows due to their ability to measure flow which changes direction, and to withstand hostile environments. However, they are not available commercially and researchers must take it upon themselves to make and manufacture them. S-type pitot probes (S-probes) work on the same principle as bi-directional probes, measuring the differential pressure between two openings, thereby offering the same benefits. However, S-probes also feature reliable manufacturing and calibration standards. In this study, the performance of bi-directional and S-probes is characterized against pitot-static probes in two scenarios. First, measurements of a steady, smooth flow in a well-characterized wind tunnel are examined. Second, the probes are used to measure the velocity profile across a turbulent jet from a blower fan. In both scenarios, the S-probe performed comparable to or better than the bi-directional probe in terms of accuracy. It is found that S-probes have similar performance to bi-directional probes in well conditioned flows. In the turbulent jet flow measurements, S-probe measurements are within 2% of pitot-static measurements in the core region of the jet, while bi-directional probes are within 6%.</description><identifier>ISSN: 1540-7489</identifier><identifier>EISSN: 1873-2704</identifier><identifier>DOI: 10.1016/j.proci.2024.105557</identifier><identifier>PMID: 39449959</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Flow measurement ; Probe characterization ; Turbulent jet ; Wind tunnel</subject><ispartof>Proceedings of the Combustion Institute, 2024, Vol.40 (1-4), p.105557, Article 105557</ispartof><rights>2024</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c340t-60d537466f4f459a910f068e341c0f4032f06d530e7b5e2674c1fab834140e013</cites><orcidid>0000-0002-0799-3418</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,777,781,882,4010,27904,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39449959$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Di Cristina, Giovanni</creatorcontrib><creatorcontrib>Bryant, Rodney A.</creatorcontrib><title>Comparison of two flow measurement devices for use in fire experiments</title><title>Proceedings of the Combustion Institute</title><addtitle>Proc Combust Inst</addtitle><description>Bi-directional probes are utilized throughout fire science to measure fire-induced flows due to their ability to measure flow which changes direction, and to withstand hostile environments. However, they are not available commercially and researchers must take it upon themselves to make and manufacture them. S-type pitot probes (S-probes) work on the same principle as bi-directional probes, measuring the differential pressure between two openings, thereby offering the same benefits. However, S-probes also feature reliable manufacturing and calibration standards. In this study, the performance of bi-directional and S-probes is characterized against pitot-static probes in two scenarios. First, measurements of a steady, smooth flow in a well-characterized wind tunnel are examined. Second, the probes are used to measure the velocity profile across a turbulent jet from a blower fan. In both scenarios, the S-probe performed comparable to or better than the bi-directional probe in terms of accuracy. It is found that S-probes have similar performance to bi-directional probes in well conditioned flows. In the turbulent jet flow measurements, S-probe measurements are within 2% of pitot-static measurements in the core region of the jet, while bi-directional probes are within 6%.</description><subject>Flow measurement</subject><subject>Probe characterization</subject><subject>Turbulent jet</subject><subject>Wind tunnel</subject><issn>1540-7489</issn><issn>1873-2704</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9UctO5DAQtFaslucXICEfuWRox3Y8OSCERrwkpL3sni2P0waPkjjYyQB_j4cBxF72ZLu7uqpdRcgxgxkDVp2tZkMM1s9KKEWuSCnVD7LH5ooXpQKxk-9SQKHEvN4l-ymtALgCLn-RXV4LUdey3iPXi9ANJvoUehocHZ8DdW14ph2aNEXssB9pg2tvMVEXIp0SUt9T5yNSfBkw-g0kHZKfzrQJjz7OA_L3-urP4ra4_31zt7i8LywXMBYVNJIrUVVOOCFrUzNwUM2RC2bBCeBlfmYIoFpKLCslLHNmOc99AQiMH5CLLe8wLTtsbNaOptVDXsPEVx2M1_92ev-oH8JaMybz91mVGU4_GGJ4mjCNuvPJYtuaHsOUNGclyFpxvoHyLdTGkFJE96XDQG8i0Cv9HoHeRKC3EeSpk-8rfs18ep4B51sAZqPWHqNO1mNvscmm2lE3wf9X4A1Ly5i_</recordid><startdate>2024</startdate><enddate>2024</enddate><creator>Di Cristina, Giovanni</creator><creator>Bryant, Rodney A.</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-0799-3418</orcidid></search><sort><creationdate>2024</creationdate><title>Comparison of two flow measurement devices for use in fire experiments</title><author>Di Cristina, Giovanni ; Bryant, Rodney A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c340t-60d537466f4f459a910f068e341c0f4032f06d530e7b5e2674c1fab834140e013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Flow measurement</topic><topic>Probe characterization</topic><topic>Turbulent jet</topic><topic>Wind tunnel</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Di Cristina, Giovanni</creatorcontrib><creatorcontrib>Bryant, Rodney A.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Proceedings of the Combustion Institute</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Di Cristina, Giovanni</au><au>Bryant, Rodney A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of two flow measurement devices for use in fire experiments</atitle><jtitle>Proceedings of the Combustion Institute</jtitle><addtitle>Proc Combust Inst</addtitle><date>2024</date><risdate>2024</risdate><volume>40</volume><issue>1-4</issue><spage>105557</spage><pages>105557-</pages><artnum>105557</artnum><issn>1540-7489</issn><eissn>1873-2704</eissn><abstract>Bi-directional probes are utilized throughout fire science to measure fire-induced flows due to their ability to measure flow which changes direction, and to withstand hostile environments. However, they are not available commercially and researchers must take it upon themselves to make and manufacture them. S-type pitot probes (S-probes) work on the same principle as bi-directional probes, measuring the differential pressure between two openings, thereby offering the same benefits. However, S-probes also feature reliable manufacturing and calibration standards. In this study, the performance of bi-directional and S-probes is characterized against pitot-static probes in two scenarios. First, measurements of a steady, smooth flow in a well-characterized wind tunnel are examined. Second, the probes are used to measure the velocity profile across a turbulent jet from a blower fan. In both scenarios, the S-probe performed comparable to or better than the bi-directional probe in terms of accuracy. It is found that S-probes have similar performance to bi-directional probes in well conditioned flows. In the turbulent jet flow measurements, S-probe measurements are within 2% of pitot-static measurements in the core region of the jet, while bi-directional probes are within 6%.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>39449959</pmid><doi>10.1016/j.proci.2024.105557</doi><orcidid>https://orcid.org/0000-0002-0799-3418</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1540-7489
ispartof Proceedings of the Combustion Institute, 2024, Vol.40 (1-4), p.105557, Article 105557
issn 1540-7489
1873-2704
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11500316
source ScienceDirect Freedom Collection
subjects Flow measurement
Probe characterization
Turbulent jet
Wind tunnel
title Comparison of two flow measurement devices for use in fire experiments
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T06%3A59%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20two%20flow%20measurement%20devices%20for%20use%20in%20fire%20experiments&rft.jtitle=Proceedings%20of%20the%20Combustion%20Institute&rft.au=Di%20Cristina,%20Giovanni&rft.date=2024&rft.volume=40&rft.issue=1-4&rft.spage=105557&rft.pages=105557-&rft.artnum=105557&rft.issn=1540-7489&rft.eissn=1873-2704&rft_id=info:doi/10.1016/j.proci.2024.105557&rft_dat=%3Cproquest_pubme%3E3120597336%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c340t-60d537466f4f459a910f068e341c0f4032f06d530e7b5e2674c1fab834140e013%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3120597336&rft_id=info:pmid/39449959&rfr_iscdi=true