Loading…

Cutting-edge insights: near-infrared imaging for surgical margin assessment in head and neck tumor resection: a systematic review and meta-analysis

In head and neck cancer (HNC), real-time evaluation of tumor margin status following surgical excision of the tumor is of critical importance. This systematic review aimed to assess the effectiveness of near-infrared fluorescence (NIRF) imaging for the real-time delineation of tumor margins in HNC r...

Full description

Saved in:
Bibliographic Details
Published in:Quantitative imaging in medicine and surgery 2024-12, Vol.14 (12), p.8167-8182
Main Authors: Li, Ke, Yang, Jiajin, Lian, Haosen, Tian, Zixi, Li, Chunjie, Gao, Ning, Guo, Zhiyong
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 8182
container_issue 12
container_start_page 8167
container_title Quantitative imaging in medicine and surgery
container_volume 14
creator Li, Ke
Yang, Jiajin
Lian, Haosen
Tian, Zixi
Li, Chunjie
Gao, Ning
Guo, Zhiyong
description In head and neck cancer (HNC), real-time evaluation of tumor margin status following surgical excision of the tumor is of critical importance. This systematic review aimed to assess the effectiveness of near-infrared fluorescence (NIRF) imaging for the real-time delineation of tumor margins in HNC resections. Two investigators independently conducted a comprehensive search following the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines across the PubMed, Scopus, Embase, and China National Knowledge Infrastructure (CNKI) databases until August 1 , 2023. Observational studies were included, while other studies with inappropriate study design were excluded. The primary outcomes included the specificity, sensitivity, and area under the summary receiver operating characteristic (SROC) curve when using NIRF imaging to assess surgical margins. We compared fluorescence in the resection specimen margins and residual fluorescence in the surgical cavity margins as methods of utilizing NIRF to evaluate surgical margins. Diagnostic trial quality was assessed, and statistical heterogeneity was determined. The initial search yielded 1,607 articles. After reviewing the full texts, seven articles with 103 patients were included, among which five were incorporated for quantitative analysis. The selected studies had an average score of 10.1 of quality. Heterogeneity analysis revealed I values of 26% [95% confidence interval (CI): 0-100%] and 78% (95% CI: 52-100%) for NIRF specimen imaging with close margin considered positive or negative. Comparing NIRF imaging to the gold standard of pathology for surgical margin diagnosis, with close margin considered positive, sensitivity and specificity in excised specimens were 0.84 (95% CI: 0.39-0.98) and 0.96 (95% CI: 0.80-0.99), respectively. When a close margin was considered negative, sensitivity and specificity were 0.98 (95% CI: 0.10-1.00) and 0.96 (95% CI: 0.45-1.00), respectively. The areas under the SROC curves were 0.97 (95% CI: 0.95-0.98) and 0.99 (95% CI: 0.98-1.00), respectively. A quantitative analysis of residual fluorescence at surgical cavity margins was not performed due to an insufficient number of studies. NIRF imaging is a promising method for real-time surgical margin assessment of HNC. With its robust diagnostic capabilities in excised tumor specimens, it is also an effective technique for detecting residual tumor fluorescence in the su
doi_str_mv 10.21037/qims-24-564
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11651944</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3147135228</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1494-a5816742cdede1f26cb2dd9d61ab8bc052ecb38601df6868d119e3c35fd0d4853</originalsourceid><addsrcrecordid>eNpVkUtv1TAQhSMEolXpjjXykgUu8SNO0g1CV1CQKrGBtTWxJ7mGxGk9Tqv7O_jDmL4Es5mR_c2xj05VvRb1mRS1at9fh4W41Lwx-ll1LKVUXKvaPH-cZS-PqlOin3WpthOtqF9WR6o3fWea5rj6vdtyDnHi6CdkIVKY9pnOWURIPMQxQULPwgJTgdi4JkZbmoKDmS1QhsiACIkWjLmssz2CZxB9EXC_WN6WspGQ0OWwxnMGjA6UcYEcXDm_CXh7Ry-YgUOE-UCBXlUvRpgJTx_6SfXj86fvuy_88tvF193HS-6E7jWHphOm1dJ59ChGadwgve-9ETB0g6sbiW5QnamFH01nOi9Ej8qpZvS1112jTqoP97pX27Cgd8VCgtlepWI3HewKwf5_E8PeTuuNFcI0ote6KLx9UEjr9YaU7RLI4TxDxHUjq4RuhWqk7Ar67h51aSVKOD69I2p7l6X9m6WV2pYsC_7m3789wY_JqT-isJ8l</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3147135228</pqid></control><display><type>article</type><title>Cutting-edge insights: near-infrared imaging for surgical margin assessment in head and neck tumor resection: a systematic review and meta-analysis</title><source>Open Access: PubMed Central</source><creator>Li, Ke ; Yang, Jiajin ; Lian, Haosen ; Tian, Zixi ; Li, Chunjie ; Gao, Ning ; Guo, Zhiyong</creator><creatorcontrib>Li, Ke ; Yang, Jiajin ; Lian, Haosen ; Tian, Zixi ; Li, Chunjie ; Gao, Ning ; Guo, Zhiyong</creatorcontrib><description>In head and neck cancer (HNC), real-time evaluation of tumor margin status following surgical excision of the tumor is of critical importance. This systematic review aimed to assess the effectiveness of near-infrared fluorescence (NIRF) imaging for the real-time delineation of tumor margins in HNC resections. Two investigators independently conducted a comprehensive search following the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines across the PubMed, Scopus, Embase, and China National Knowledge Infrastructure (CNKI) databases until August 1 , 2023. Observational studies were included, while other studies with inappropriate study design were excluded. The primary outcomes included the specificity, sensitivity, and area under the summary receiver operating characteristic (SROC) curve when using NIRF imaging to assess surgical margins. We compared fluorescence in the resection specimen margins and residual fluorescence in the surgical cavity margins as methods of utilizing NIRF to evaluate surgical margins. Diagnostic trial quality was assessed, and statistical heterogeneity was determined. The initial search yielded 1,607 articles. After reviewing the full texts, seven articles with 103 patients were included, among which five were incorporated for quantitative analysis. The selected studies had an average score of 10.1 of quality. Heterogeneity analysis revealed I values of 26% [95% confidence interval (CI): 0-100%] and 78% (95% CI: 52-100%) for NIRF specimen imaging with close margin considered positive or negative. Comparing NIRF imaging to the gold standard of pathology for surgical margin diagnosis, with close margin considered positive, sensitivity and specificity in excised specimens were 0.84 (95% CI: 0.39-0.98) and 0.96 (95% CI: 0.80-0.99), respectively. When a close margin was considered negative, sensitivity and specificity were 0.98 (95% CI: 0.10-1.00) and 0.96 (95% CI: 0.45-1.00), respectively. The areas under the SROC curves were 0.97 (95% CI: 0.95-0.98) and 0.99 (95% CI: 0.98-1.00), respectively. A quantitative analysis of residual fluorescence at surgical cavity margins was not performed due to an insufficient number of studies. NIRF imaging is a promising method for real-time surgical margin assessment of HNC. With its robust diagnostic capabilities in excised tumor specimens, it is also an effective technique for detecting residual tumor fluorescence in the surgical cavity for supplementary assessment. But the results should be interpreted with caution.</description><identifier>ISSN: 2223-4292</identifier><identifier>EISSN: 2223-4306</identifier><identifier>DOI: 10.21037/qims-24-564</identifier><identifier>PMID: 39698655</identifier><language>eng</language><publisher>China: AME Publishing Company</publisher><subject>Original</subject><ispartof>Quantitative imaging in medicine and surgery, 2024-12, Vol.14 (12), p.8167-8182</ispartof><rights>2024 AME Publishing Company. All rights reserved.</rights><rights>2024 AME Publishing Company. All rights reserved. 2024 AME Publishing Company.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0001-8791-0020</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11651944/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11651944/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39698655$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Li, Ke</creatorcontrib><creatorcontrib>Yang, Jiajin</creatorcontrib><creatorcontrib>Lian, Haosen</creatorcontrib><creatorcontrib>Tian, Zixi</creatorcontrib><creatorcontrib>Li, Chunjie</creatorcontrib><creatorcontrib>Gao, Ning</creatorcontrib><creatorcontrib>Guo, Zhiyong</creatorcontrib><title>Cutting-edge insights: near-infrared imaging for surgical margin assessment in head and neck tumor resection: a systematic review and meta-analysis</title><title>Quantitative imaging in medicine and surgery</title><addtitle>Quant Imaging Med Surg</addtitle><description>In head and neck cancer (HNC), real-time evaluation of tumor margin status following surgical excision of the tumor is of critical importance. This systematic review aimed to assess the effectiveness of near-infrared fluorescence (NIRF) imaging for the real-time delineation of tumor margins in HNC resections. Two investigators independently conducted a comprehensive search following the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines across the PubMed, Scopus, Embase, and China National Knowledge Infrastructure (CNKI) databases until August 1 , 2023. Observational studies were included, while other studies with inappropriate study design were excluded. The primary outcomes included the specificity, sensitivity, and area under the summary receiver operating characteristic (SROC) curve when using NIRF imaging to assess surgical margins. We compared fluorescence in the resection specimen margins and residual fluorescence in the surgical cavity margins as methods of utilizing NIRF to evaluate surgical margins. Diagnostic trial quality was assessed, and statistical heterogeneity was determined. The initial search yielded 1,607 articles. After reviewing the full texts, seven articles with 103 patients were included, among which five were incorporated for quantitative analysis. The selected studies had an average score of 10.1 of quality. Heterogeneity analysis revealed I values of 26% [95% confidence interval (CI): 0-100%] and 78% (95% CI: 52-100%) for NIRF specimen imaging with close margin considered positive or negative. Comparing NIRF imaging to the gold standard of pathology for surgical margin diagnosis, with close margin considered positive, sensitivity and specificity in excised specimens were 0.84 (95% CI: 0.39-0.98) and 0.96 (95% CI: 0.80-0.99), respectively. When a close margin was considered negative, sensitivity and specificity were 0.98 (95% CI: 0.10-1.00) and 0.96 (95% CI: 0.45-1.00), respectively. The areas under the SROC curves were 0.97 (95% CI: 0.95-0.98) and 0.99 (95% CI: 0.98-1.00), respectively. A quantitative analysis of residual fluorescence at surgical cavity margins was not performed due to an insufficient number of studies. NIRF imaging is a promising method for real-time surgical margin assessment of HNC. With its robust diagnostic capabilities in excised tumor specimens, it is also an effective technique for detecting residual tumor fluorescence in the surgical cavity for supplementary assessment. But the results should be interpreted with caution.</description><subject>Original</subject><issn>2223-4292</issn><issn>2223-4306</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpVkUtv1TAQhSMEolXpjjXykgUu8SNO0g1CV1CQKrGBtTWxJ7mGxGk9Tqv7O_jDmL4Es5mR_c2xj05VvRb1mRS1at9fh4W41Lwx-ll1LKVUXKvaPH-cZS-PqlOin3WpthOtqF9WR6o3fWea5rj6vdtyDnHi6CdkIVKY9pnOWURIPMQxQULPwgJTgdi4JkZbmoKDmS1QhsiACIkWjLmssz2CZxB9EXC_WN6WspGQ0OWwxnMGjA6UcYEcXDm_CXh7Ry-YgUOE-UCBXlUvRpgJTx_6SfXj86fvuy_88tvF193HS-6E7jWHphOm1dJ59ChGadwgve-9ETB0g6sbiW5QnamFH01nOi9Ej8qpZvS1112jTqoP97pX27Cgd8VCgtlepWI3HewKwf5_E8PeTuuNFcI0ote6KLx9UEjr9YaU7RLI4TxDxHUjq4RuhWqk7Ar67h51aSVKOD69I2p7l6X9m6WV2pYsC_7m3789wY_JqT-isJ8l</recordid><startdate>20241205</startdate><enddate>20241205</enddate><creator>Li, Ke</creator><creator>Yang, Jiajin</creator><creator>Lian, Haosen</creator><creator>Tian, Zixi</creator><creator>Li, Chunjie</creator><creator>Gao, Ning</creator><creator>Guo, Zhiyong</creator><general>AME Publishing Company</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0001-8791-0020</orcidid></search><sort><creationdate>20241205</creationdate><title>Cutting-edge insights: near-infrared imaging for surgical margin assessment in head and neck tumor resection: a systematic review and meta-analysis</title><author>Li, Ke ; Yang, Jiajin ; Lian, Haosen ; Tian, Zixi ; Li, Chunjie ; Gao, Ning ; Guo, Zhiyong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1494-a5816742cdede1f26cb2dd9d61ab8bc052ecb38601df6868d119e3c35fd0d4853</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Original</topic><toplevel>online_resources</toplevel><creatorcontrib>Li, Ke</creatorcontrib><creatorcontrib>Yang, Jiajin</creatorcontrib><creatorcontrib>Lian, Haosen</creatorcontrib><creatorcontrib>Tian, Zixi</creatorcontrib><creatorcontrib>Li, Chunjie</creatorcontrib><creatorcontrib>Gao, Ning</creatorcontrib><creatorcontrib>Guo, Zhiyong</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Quantitative imaging in medicine and surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Ke</au><au>Yang, Jiajin</au><au>Lian, Haosen</au><au>Tian, Zixi</au><au>Li, Chunjie</au><au>Gao, Ning</au><au>Guo, Zhiyong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Cutting-edge insights: near-infrared imaging for surgical margin assessment in head and neck tumor resection: a systematic review and meta-analysis</atitle><jtitle>Quantitative imaging in medicine and surgery</jtitle><addtitle>Quant Imaging Med Surg</addtitle><date>2024-12-05</date><risdate>2024</risdate><volume>14</volume><issue>12</issue><spage>8167</spage><epage>8182</epage><pages>8167-8182</pages><issn>2223-4292</issn><eissn>2223-4306</eissn><abstract>In head and neck cancer (HNC), real-time evaluation of tumor margin status following surgical excision of the tumor is of critical importance. This systematic review aimed to assess the effectiveness of near-infrared fluorescence (NIRF) imaging for the real-time delineation of tumor margins in HNC resections. Two investigators independently conducted a comprehensive search following the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines across the PubMed, Scopus, Embase, and China National Knowledge Infrastructure (CNKI) databases until August 1 , 2023. Observational studies were included, while other studies with inappropriate study design were excluded. The primary outcomes included the specificity, sensitivity, and area under the summary receiver operating characteristic (SROC) curve when using NIRF imaging to assess surgical margins. We compared fluorescence in the resection specimen margins and residual fluorescence in the surgical cavity margins as methods of utilizing NIRF to evaluate surgical margins. Diagnostic trial quality was assessed, and statistical heterogeneity was determined. The initial search yielded 1,607 articles. After reviewing the full texts, seven articles with 103 patients were included, among which five were incorporated for quantitative analysis. The selected studies had an average score of 10.1 of quality. Heterogeneity analysis revealed I values of 26% [95% confidence interval (CI): 0-100%] and 78% (95% CI: 52-100%) for NIRF specimen imaging with close margin considered positive or negative. Comparing NIRF imaging to the gold standard of pathology for surgical margin diagnosis, with close margin considered positive, sensitivity and specificity in excised specimens were 0.84 (95% CI: 0.39-0.98) and 0.96 (95% CI: 0.80-0.99), respectively. When a close margin was considered negative, sensitivity and specificity were 0.98 (95% CI: 0.10-1.00) and 0.96 (95% CI: 0.45-1.00), respectively. The areas under the SROC curves were 0.97 (95% CI: 0.95-0.98) and 0.99 (95% CI: 0.98-1.00), respectively. A quantitative analysis of residual fluorescence at surgical cavity margins was not performed due to an insufficient number of studies. NIRF imaging is a promising method for real-time surgical margin assessment of HNC. With its robust diagnostic capabilities in excised tumor specimens, it is also an effective technique for detecting residual tumor fluorescence in the surgical cavity for supplementary assessment. But the results should be interpreted with caution.</abstract><cop>China</cop><pub>AME Publishing Company</pub><pmid>39698655</pmid><doi>10.21037/qims-24-564</doi><tpages>16</tpages><orcidid>https://orcid.org/0000-0001-8791-0020</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2223-4292
ispartof Quantitative imaging in medicine and surgery, 2024-12, Vol.14 (12), p.8167-8182
issn 2223-4292
2223-4306
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11651944
source Open Access: PubMed Central
subjects Original
title Cutting-edge insights: near-infrared imaging for surgical margin assessment in head and neck tumor resection: a systematic review and meta-analysis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T13%3A12%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Cutting-edge%20insights:%20near-infrared%20imaging%20for%20surgical%20margin%20assessment%20in%20head%20and%20neck%20tumor%20resection:%20a%20systematic%20review%20and%20meta-analysis&rft.jtitle=Quantitative%20imaging%20in%20medicine%20and%20surgery&rft.au=Li,%20Ke&rft.date=2024-12-05&rft.volume=14&rft.issue=12&rft.spage=8167&rft.epage=8182&rft.pages=8167-8182&rft.issn=2223-4292&rft.eissn=2223-4306&rft_id=info:doi/10.21037/qims-24-564&rft_dat=%3Cproquest_pubme%3E3147135228%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1494-a5816742cdede1f26cb2dd9d61ab8bc052ecb38601df6868d119e3c35fd0d4853%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3147135228&rft_id=info:pmid/39698655&rfr_iscdi=true