Loading…

Assessment of Reproducibility and Agreement of the IDEAL Classification for Distal Radius Fractures

To analyze the reproducibility and intra- and interobserver agreement of the IDEAL classification for distal radius fractures.  This qualitative, analytical study evaluated 50 pairs of radiographs in two views of patients with distal radius fractures. There were ten observers with different levels o...

Full description

Saved in:
Bibliographic Details
Published in:Revista brasileira de ortopedia 2024-12, Vol.59 (6), p.e901-e906
Main Authors: Lima, João Victor da Rocha, Silva, Lucas Araújo, Feitosa, Antonio Guilherme Chagas Silva, Medeiros, Rafael Lima, Carvalho, Luis Fernando Martins, Moura, Bruno Wilson da Silva
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page e906
container_issue 6
container_start_page e901
container_title Revista brasileira de ortopedia
container_volume 59
creator Lima, João Victor da Rocha
Silva, Lucas Araújo
Feitosa, Antonio Guilherme Chagas Silva
Medeiros, Rafael Lima
Carvalho, Luis Fernando Martins
Moura, Bruno Wilson da Silva
description To analyze the reproducibility and intra- and interobserver agreement of the IDEAL classification for distal radius fractures.  This qualitative, analytical study evaluated 50 pairs of radiographs in two views of patients with distal radius fractures. There were ten observers with different levels of orthopedic training who assessed the radiographs in three different evaluations. The results underwent the Cohen and Fleiss Kappa tests to determine intra- and interobserver agreement levels. Statistical calculations used Excel and SPSS, version 26.0.  The Cohen Kappa index values for intraobserver evaluation indicated poor to little agreement (-0.177-0.259), with statistical significance in only one instance. The Fleiss Kappa index values revealed little agreement among the resident group (0.277-0.383) with statistical significance, poor to little agreement among the general orthopedists (0.114-0.225) with statistical significance in most instances, and moderate agreement among hand surgeons (0.449-0.533) with statistical significance.  The IDEAL classification had interobserver agreement levels ranging from poor to moderate, influenced by the physicians' training level. Other intraobserver agreement levels ranged from poor to little agreement but without statistical significance.
doi_str_mv 10.1055/s-0044-1792121
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11663075</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3148498823</sourcerecordid><originalsourceid>FETCH-LOGICAL-p1125-fa962e86e0f6036de0074449bc4d3d3b957d7d1f26631ebd8c9b104913dbfd863</originalsourceid><addsrcrecordid>eNpVkM9LwzAcxYMobk6vHiVHL9V8kzRtTlL2QwcDYei5pE2yRfrLpBX231twEz29w3t83uMhdAvkAUgcP4aIEM4jSCQFCmdoCjKlEWdJeo6mBAiNmAAxQVchfBASS0HFJZowmQAIyqaozEIwIdSm6XFr8dZ0vtVD6QpXuf6AVaNxtvPGnAL93uD1Yplt8LxSITjrStW7tsG29XjhQq8qvFXaDQGvvCr7wZtwjS6sqoK5OeoMva-Wb_OXaPP6vJ5nm6gDoHFk1bjOpMIQKwgT2hCScM5lUXLNNCtknOhEg6VCMDCFTktZAOESmC6sTgWboacfbjcUtdHlONmrKu-8q5U_5K1y-X-ncft8137l4xeCkSQeCfdHgm8_BxP6vHahNFWlGtMOIWfAUy7TlLIxeve37LfldC37Bkx9fCs</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3148498823</pqid></control><display><type>article</type><title>Assessment of Reproducibility and Agreement of the IDEAL Classification for Distal Radius Fractures</title><source>SciELO</source><source>PubMed Central</source><source>Thieme Connect Journals Open Access</source><creator>Lima, João Victor da Rocha ; Silva, Lucas Araújo ; Feitosa, Antonio Guilherme Chagas Silva ; Medeiros, Rafael Lima ; Carvalho, Luis Fernando Martins ; Moura, Bruno Wilson da Silva</creator><creatorcontrib>Lima, João Victor da Rocha ; Silva, Lucas Araújo ; Feitosa, Antonio Guilherme Chagas Silva ; Medeiros, Rafael Lima ; Carvalho, Luis Fernando Martins ; Moura, Bruno Wilson da Silva</creatorcontrib><description>To analyze the reproducibility and intra- and interobserver agreement of the IDEAL classification for distal radius fractures.  This qualitative, analytical study evaluated 50 pairs of radiographs in two views of patients with distal radius fractures. There were ten observers with different levels of orthopedic training who assessed the radiographs in three different evaluations. The results underwent the Cohen and Fleiss Kappa tests to determine intra- and interobserver agreement levels. Statistical calculations used Excel and SPSS, version 26.0.  The Cohen Kappa index values for intraobserver evaluation indicated poor to little agreement (-0.177-0.259), with statistical significance in only one instance. The Fleiss Kappa index values revealed little agreement among the resident group (0.277-0.383) with statistical significance, poor to little agreement among the general orthopedists (0.114-0.225) with statistical significance in most instances, and moderate agreement among hand surgeons (0.449-0.533) with statistical significance.  The IDEAL classification had interobserver agreement levels ranging from poor to moderate, influenced by the physicians' training level. Other intraobserver agreement levels ranged from poor to little agreement but without statistical significance.</description><identifier>ISSN: 0102-3616</identifier><identifier>EISSN: 1982-4378</identifier><identifier>DOI: 10.1055/s-0044-1792121</identifier><identifier>PMID: 39711623</identifier><language>eng</language><publisher>Germany: Thieme Revinter Publicações Ltda</publisher><subject>Artigo Original</subject><ispartof>Revista brasileira de ortopedia, 2024-12, Vol.59 (6), p.e901-e906</ispartof><rights>The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution 4.0 International License, permitting copying and reproduction so long as the original work is given appropriate credit ( https://creativecommons.org/licenses/by/4.0/ ).</rights><rights>The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution 4.0 International License, permitting copying and reproduction so long as the original work is given appropriate credit ( ) 2024 The Author(s).</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0001-7924-8057 ; 0009-0006-5758-3480 ; 0000-0001-9501-4517 ; 0000-0002-8509-7125 ; 0000-0002-4403-403X ; 0000-0001-7032-3372</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11663075/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11663075/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39711623$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lima, João Victor da Rocha</creatorcontrib><creatorcontrib>Silva, Lucas Araújo</creatorcontrib><creatorcontrib>Feitosa, Antonio Guilherme Chagas Silva</creatorcontrib><creatorcontrib>Medeiros, Rafael Lima</creatorcontrib><creatorcontrib>Carvalho, Luis Fernando Martins</creatorcontrib><creatorcontrib>Moura, Bruno Wilson da Silva</creatorcontrib><title>Assessment of Reproducibility and Agreement of the IDEAL Classification for Distal Radius Fractures</title><title>Revista brasileira de ortopedia</title><addtitle>Rev Bras Ortop (Sao Paulo)</addtitle><description>To analyze the reproducibility and intra- and interobserver agreement of the IDEAL classification for distal radius fractures.  This qualitative, analytical study evaluated 50 pairs of radiographs in two views of patients with distal radius fractures. There were ten observers with different levels of orthopedic training who assessed the radiographs in three different evaluations. The results underwent the Cohen and Fleiss Kappa tests to determine intra- and interobserver agreement levels. Statistical calculations used Excel and SPSS, version 26.0.  The Cohen Kappa index values for intraobserver evaluation indicated poor to little agreement (-0.177-0.259), with statistical significance in only one instance. The Fleiss Kappa index values revealed little agreement among the resident group (0.277-0.383) with statistical significance, poor to little agreement among the general orthopedists (0.114-0.225) with statistical significance in most instances, and moderate agreement among hand surgeons (0.449-0.533) with statistical significance.  The IDEAL classification had interobserver agreement levels ranging from poor to moderate, influenced by the physicians' training level. Other intraobserver agreement levels ranged from poor to little agreement but without statistical significance.</description><subject>Artigo Original</subject><issn>0102-3616</issn><issn>1982-4378</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpVkM9LwzAcxYMobk6vHiVHL9V8kzRtTlL2QwcDYei5pE2yRfrLpBX231twEz29w3t83uMhdAvkAUgcP4aIEM4jSCQFCmdoCjKlEWdJeo6mBAiNmAAxQVchfBASS0HFJZowmQAIyqaozEIwIdSm6XFr8dZ0vtVD6QpXuf6AVaNxtvPGnAL93uD1Yplt8LxSITjrStW7tsG29XjhQq8qvFXaDQGvvCr7wZtwjS6sqoK5OeoMva-Wb_OXaPP6vJ5nm6gDoHFk1bjOpMIQKwgT2hCScM5lUXLNNCtknOhEg6VCMDCFTktZAOESmC6sTgWboacfbjcUtdHlONmrKu-8q5U_5K1y-X-ncft8137l4xeCkSQeCfdHgm8_BxP6vHahNFWlGtMOIWfAUy7TlLIxeve37LfldC37Bkx9fCs</recordid><startdate>202412</startdate><enddate>202412</enddate><creator>Lima, João Victor da Rocha</creator><creator>Silva, Lucas Araújo</creator><creator>Feitosa, Antonio Guilherme Chagas Silva</creator><creator>Medeiros, Rafael Lima</creator><creator>Carvalho, Luis Fernando Martins</creator><creator>Moura, Bruno Wilson da Silva</creator><general>Thieme Revinter Publicações Ltda</general><scope>NPM</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0001-7924-8057</orcidid><orcidid>https://orcid.org/0009-0006-5758-3480</orcidid><orcidid>https://orcid.org/0000-0001-9501-4517</orcidid><orcidid>https://orcid.org/0000-0002-8509-7125</orcidid><orcidid>https://orcid.org/0000-0002-4403-403X</orcidid><orcidid>https://orcid.org/0000-0001-7032-3372</orcidid></search><sort><creationdate>202412</creationdate><title>Assessment of Reproducibility and Agreement of the IDEAL Classification for Distal Radius Fractures</title><author>Lima, João Victor da Rocha ; Silva, Lucas Araújo ; Feitosa, Antonio Guilherme Chagas Silva ; Medeiros, Rafael Lima ; Carvalho, Luis Fernando Martins ; Moura, Bruno Wilson da Silva</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p1125-fa962e86e0f6036de0074449bc4d3d3b957d7d1f26631ebd8c9b104913dbfd863</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Artigo Original</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lima, João Victor da Rocha</creatorcontrib><creatorcontrib>Silva, Lucas Araújo</creatorcontrib><creatorcontrib>Feitosa, Antonio Guilherme Chagas Silva</creatorcontrib><creatorcontrib>Medeiros, Rafael Lima</creatorcontrib><creatorcontrib>Carvalho, Luis Fernando Martins</creatorcontrib><creatorcontrib>Moura, Bruno Wilson da Silva</creatorcontrib><collection>PubMed</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Revista brasileira de ortopedia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lima, João Victor da Rocha</au><au>Silva, Lucas Araújo</au><au>Feitosa, Antonio Guilherme Chagas Silva</au><au>Medeiros, Rafael Lima</au><au>Carvalho, Luis Fernando Martins</au><au>Moura, Bruno Wilson da Silva</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessment of Reproducibility and Agreement of the IDEAL Classification for Distal Radius Fractures</atitle><jtitle>Revista brasileira de ortopedia</jtitle><addtitle>Rev Bras Ortop (Sao Paulo)</addtitle><date>2024-12</date><risdate>2024</risdate><volume>59</volume><issue>6</issue><spage>e901</spage><epage>e906</epage><pages>e901-e906</pages><issn>0102-3616</issn><eissn>1982-4378</eissn><abstract>To analyze the reproducibility and intra- and interobserver agreement of the IDEAL classification for distal radius fractures.  This qualitative, analytical study evaluated 50 pairs of radiographs in two views of patients with distal radius fractures. There were ten observers with different levels of orthopedic training who assessed the radiographs in three different evaluations. The results underwent the Cohen and Fleiss Kappa tests to determine intra- and interobserver agreement levels. Statistical calculations used Excel and SPSS, version 26.0.  The Cohen Kappa index values for intraobserver evaluation indicated poor to little agreement (-0.177-0.259), with statistical significance in only one instance. The Fleiss Kappa index values revealed little agreement among the resident group (0.277-0.383) with statistical significance, poor to little agreement among the general orthopedists (0.114-0.225) with statistical significance in most instances, and moderate agreement among hand surgeons (0.449-0.533) with statistical significance.  The IDEAL classification had interobserver agreement levels ranging from poor to moderate, influenced by the physicians' training level. Other intraobserver agreement levels ranged from poor to little agreement but without statistical significance.</abstract><cop>Germany</cop><pub>Thieme Revinter Publicações Ltda</pub><pmid>39711623</pmid><doi>10.1055/s-0044-1792121</doi><orcidid>https://orcid.org/0000-0001-7924-8057</orcidid><orcidid>https://orcid.org/0009-0006-5758-3480</orcidid><orcidid>https://orcid.org/0000-0001-9501-4517</orcidid><orcidid>https://orcid.org/0000-0002-8509-7125</orcidid><orcidid>https://orcid.org/0000-0002-4403-403X</orcidid><orcidid>https://orcid.org/0000-0001-7032-3372</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0102-3616
ispartof Revista brasileira de ortopedia, 2024-12, Vol.59 (6), p.e901-e906
issn 0102-3616
1982-4378
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11663075
source SciELO; PubMed Central; Thieme Connect Journals Open Access
subjects Artigo Original
title Assessment of Reproducibility and Agreement of the IDEAL Classification for Distal Radius Fractures
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T22%3A31%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessment%20of%20Reproducibility%20and%20Agreement%20of%20the%20IDEAL%20Classification%20for%20Distal%20Radius%20Fractures&rft.jtitle=Revista%20brasileira%20de%20ortopedia&rft.au=Lima,%20Jo%C3%A3o%20Victor%20da%20Rocha&rft.date=2024-12&rft.volume=59&rft.issue=6&rft.spage=e901&rft.epage=e906&rft.pages=e901-e906&rft.issn=0102-3616&rft.eissn=1982-4378&rft_id=info:doi/10.1055/s-0044-1792121&rft_dat=%3Cproquest_pubme%3E3148498823%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p1125-fa962e86e0f6036de0074449bc4d3d3b957d7d1f26631ebd8c9b104913dbfd863%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3148498823&rft_id=info:pmid/39711623&rfr_iscdi=true