Loading…
Electrophysiological alternans and restitution during acute regional ischaemia in myocardium of anaesthetized pig
1. Alternate long and short action potential durations, or electrical alternans, has only been sporadically observed in ischaemic myocardium in situ. We systematically studied alternans in the latter to characterize the phenomenon, relate it to ventricular arrhythmia and suggest possible mechanisms....
Saved in:
Published in: | The Journal of physiology 1988-08, Vol.402 (1), p.315-333 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | 1. Alternate long and short action potential durations, or electrical alternans, has only been sporadically observed in ischaemic
myocardium in situ. We systematically studied alternans in the latter to characterize the phenomenon, relate it to ventricular
arrhythmia and suggest possible mechanisms. 2. Sixteen Landrace pigs were anaesthetized (Azaperone, N2O and O2), ventilated
and the hearts exposed. A branch of the left coronary artery was ligated. Left intraventricular and systemic pressures were
monitored. Monophasic action potentials were recorded simultaneously with up to five suction electrodes in and around the
proposed ischaemia area. 3. A computer measured the duration of every action potential, at several phases of repolarization,
throughout the first hour of ischaemia. This allowed the systematic study of the alternans. Measurements during defined stimulus
protocols were also made for the construction of electrical restitution curves. 4. Alternans was found in all recordings within
the ischaemic area and in two-thirds of those in the 'border' area. There was no alternans in non-ischaemic areas. 5. The
alternans, when action potential duration was plotted for every beat, appeared as an oscillation which was pleomorphic. It
could be: (a) stable for hundreds of beats; (b) switched or triggered (by one extraneous beat having a different cycle length)
between one stable state with high and one with low or absent alternans; (c) damped; (d) undamped to take a crescendo form,
sometimes preceding ventricular fibrillation. 6. The alternans in general showed an ill-defined peak incidence between about
200 to 1500 beats after the onset of ischaemia, and a clearer late peak at about 3000 beats. These periods occurred at about
2-7 min and 15-40 min, corresponding to so-called phase 1A and 1B arrhythmia respectively. Only the late peak was seen with
triggered alternans. 7. The electrical restitution curve for the action potential duration during ischaemia when compared
with curves, constructed with data from non-ischaemic myocardium, showed a progressive depression in plateau, a reduction
in magnitude and was flattened at 1 h. However, there was a reversal or reduction in decline at about 15-45 min. 8. We propose
that electrical alternans is a distinctive electrophysiological characteristic of ischaemic myocardium which may be causally
related to ventricular arrhythmia and fibrillation, and that at least two mechanisms contribute to the alternans: (i) electri |
---|---|
ISSN: | 0022-3751 1469-7793 |
DOI: | 10.1113/jphysiol.1988.sp017206 |