Loading…
Voltage-clamp analysis of somatic gamma-aminobutyric acid responses in adult rat hippocampal CA1 neurones in vitro
1. The response of CA1 pyramidal neurones to somatic application of gamma-aminobutyric acid (GABA) was studied in adult hippocampal slices using single-electrode voltage-clamp techniques. 2. Small ionophoretic applications of GABA produced a pure outward current at the cell resting potential when re...
Saved in:
Published in: | The Journal of physiology 1987-03, Vol.384 (1), p.27-37 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | 1. The response of CA1 pyramidal neurones to somatic application of gamma-aminobutyric acid (GABA) was studied in adult hippocampal
slices using single-electrode voltage-clamp techniques. 2. Small ionophoretic applications of GABA produced a pure outward
current at the cell resting potential when recording with potassium-acetate-filled microelectrodes. This response reversed
at a membrane potential of -69 +/- 5 mV (mean +/- 1 S.D.; n = 20). In recordings made with caesium-chloride-filled electrodes
the GABA response reversed at -24 +/- 12 mV (n = 9). 3. The effect of different holding potentials on the size of the GABA
response was examined in the range of -100 to -40 mV in twenty neurones using potassium-acetate-filled electrodes. In every
case outward rectification of the response was observed. For twelve neurones the mean ratio (+/- 1 S.D. of the mean) of the
conductance increase produced by GABA at -55 mV compared to -85 mV was 1.9 +/- 0.5. 4. Step changes in holding potential resulted
in shifts in chloride equilibrium potential (ECl), as determined by time-dependent changes in the size of GABA-induced currents.
The new value of ECl was generally reached within a few seconds of altering the membrane potential. Shifts in ECl did not
appear to affect the extent of rectification but would cause underestimates of conductance measurements unless these were
'instantaneous'. The mean ratio (+/- 1 S.D. of the mean) of the 'instantaneous' conductance increase produced by GABA at 13
mV positive to that at 13 mV negative to ECl was 1.8 +/- 0.3. 5. The outward rectification was greater than that predicted
by the constant-field equation. Possible factors that might contribute towards the rectification and its physiological significance
are discussed. |
---|---|
ISSN: | 0022-3751 1469-7793 |
DOI: | 10.1113/jphysiol.1987.sp016441 |