Loading…

comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows

Systolic blood pressure measurement obtained with a pulse oximeter has been compared to values obtained by other indirect methods in man. Direct pressure measurement is subject to less error than indirect techniques. This study was designed to compare systolic pressure values obtained using a pulse...

Full description

Saved in:
Bibliographic Details
Published in:Canadian journal of veterinary research 1994-04, Vol.58 (2), p.144-147
Main Authors: Caulkett, N.A, Duke, T, Bailey, J.V
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 147
container_issue 2
container_start_page 144
container_title Canadian journal of veterinary research
container_volume 58
creator Caulkett, N.A
Duke, T
Bailey, J.V
description Systolic blood pressure measurement obtained with a pulse oximeter has been compared to values obtained by other indirect methods in man. Direct pressure measurement is subject to less error than indirect techniques. This study was designed to compare systolic pressure values obtained using a pulse oximeter, with values obtained by direct arterial pressure measurement. The pulse oximeter waveform was used as an indication of perfusion. A blood pressure cuff was applied proximal to the pulse oximeter probe. The cuff was inflated until the oximeter waveform disappeared, this value was recorded as the systolic pressure at the disappearance of the waveform (SPD). The cuff was inflated to a pressure > 200 mmHg, then gradually deflated until the waveform reappeared, this value was recorded as the systolic pressure at reappearance of the waveform (SPR). The average of the two values, SPD and SPR, was calculated and recorded as SPA. The study was performed in sows (n = 21) undergoing cesarean section under epidural anesthesia and IV sedation. A total of 280 measurements were made of SPD, SPR and SPA. Regression analysis of SPA and direct measurement revealed a correlation coefficient (r) of 0.81. Calculation of mean difference (bias) and standard deviation of the bias (precision) for direct pressure--SPA revealed a value of 1.3 +/- 12.1. When compared with direct measurement, the correlation of this technique was similar to that recorded for other indirect techniques used in small animals. This indicates that this technique would be useful for following systolic pressure trends.
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1263681</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>76556139</sourcerecordid><originalsourceid>FETCH-LOGICAL-f285t-1075d6e5a184f32a0c4c73517e228263e2cf2db4e95c0d7fd48048861f429123</originalsourceid><addsrcrecordid>eNptkctOwzAURLMAlVL4BIRXrIjkRx7OBglVvKRKLChry7FvWqMkDrYDlK_gkzFqxUNidRczOnNHs5dMMWc4rTDGB8mh908Y07KgbJJMOMZZnuFp8qFsN0hnvO2RbZDf-GBbo1DdWqvR4MD70QHqQH7dDvqAbB2k6UGj0Zt-hSQaxtYDsm-mgwDuHMleI20cqPDD-5dk-ugFH9YQzHsEevvqj5L9Rkbe8e7OkuX11XJ-my7ub-7ml4u0oTwPKcFlrgvIJeFZw6jEKlMly0kJlHJaMKCqobrOoMoV1mWjM44zzgvSZLQilM2Siy12GOsOtIrvONmKwZlOuo2w0oi_Sm_WYmVfBInwgpMIONsBnH0eYwnRGa-gbWMjO3pRFnleEFZF48nvpO-I3QRRP93qjbRCruIU4vGBYsIwKXmci7JPn8aP8g</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76556139</pqid></control><display><type>article</type><title>comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows</title><source>PubMed Central Free</source><creator>Caulkett, N.A ; Duke, T ; Bailey, J.V</creator><creatorcontrib>Caulkett, N.A ; Duke, T ; Bailey, J.V</creatorcontrib><description>Systolic blood pressure measurement obtained with a pulse oximeter has been compared to values obtained by other indirect methods in man. Direct pressure measurement is subject to less error than indirect techniques. This study was designed to compare systolic pressure values obtained using a pulse oximeter, with values obtained by direct arterial pressure measurement. The pulse oximeter waveform was used as an indication of perfusion. A blood pressure cuff was applied proximal to the pulse oximeter probe. The cuff was inflated until the oximeter waveform disappeared, this value was recorded as the systolic pressure at the disappearance of the waveform (SPD). The cuff was inflated to a pressure &gt; 200 mmHg, then gradually deflated until the waveform reappeared, this value was recorded as the systolic pressure at reappearance of the waveform (SPR). The average of the two values, SPD and SPR, was calculated and recorded as SPA. The study was performed in sows (n = 21) undergoing cesarean section under epidural anesthesia and IV sedation. A total of 280 measurements were made of SPD, SPR and SPA. Regression analysis of SPA and direct measurement revealed a correlation coefficient (r) of 0.81. Calculation of mean difference (bias) and standard deviation of the bias (precision) for direct pressure--SPA revealed a value of 1.3 +/- 12.1. When compared with direct measurement, the correlation of this technique was similar to that recorded for other indirect techniques used in small animals. This indicates that this technique would be useful for following systolic pressure trends.</description><identifier>ISSN: 0830-9000</identifier><identifier>PMID: 8004540</identifier><language>eng</language><publisher>Canada</publisher><subject>anesthesia ; Anesthesia, Epidural - veterinary ; Animals ; Blood Pressure ; Blood Pressure Determination - methods ; Blood Pressure Determination - veterinary ; Female ; metering ; meters (equipment) ; optical plethysmography ; Oximetry - veterinary ; Regression Analysis ; sows ; Swine - physiology ; Systole</subject><ispartof>Canadian journal of veterinary research, 1994-04, Vol.58 (2), p.144-147</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC1263681/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC1263681/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8004540$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Caulkett, N.A</creatorcontrib><creatorcontrib>Duke, T</creatorcontrib><creatorcontrib>Bailey, J.V</creatorcontrib><title>comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows</title><title>Canadian journal of veterinary research</title><addtitle>Can J Vet Res</addtitle><description>Systolic blood pressure measurement obtained with a pulse oximeter has been compared to values obtained by other indirect methods in man. Direct pressure measurement is subject to less error than indirect techniques. This study was designed to compare systolic pressure values obtained using a pulse oximeter, with values obtained by direct arterial pressure measurement. The pulse oximeter waveform was used as an indication of perfusion. A blood pressure cuff was applied proximal to the pulse oximeter probe. The cuff was inflated until the oximeter waveform disappeared, this value was recorded as the systolic pressure at the disappearance of the waveform (SPD). The cuff was inflated to a pressure &gt; 200 mmHg, then gradually deflated until the waveform reappeared, this value was recorded as the systolic pressure at reappearance of the waveform (SPR). The average of the two values, SPD and SPR, was calculated and recorded as SPA. The study was performed in sows (n = 21) undergoing cesarean section under epidural anesthesia and IV sedation. A total of 280 measurements were made of SPD, SPR and SPA. Regression analysis of SPA and direct measurement revealed a correlation coefficient (r) of 0.81. Calculation of mean difference (bias) and standard deviation of the bias (precision) for direct pressure--SPA revealed a value of 1.3 +/- 12.1. When compared with direct measurement, the correlation of this technique was similar to that recorded for other indirect techniques used in small animals. This indicates that this technique would be useful for following systolic pressure trends.</description><subject>anesthesia</subject><subject>Anesthesia, Epidural - veterinary</subject><subject>Animals</subject><subject>Blood Pressure</subject><subject>Blood Pressure Determination - methods</subject><subject>Blood Pressure Determination - veterinary</subject><subject>Female</subject><subject>metering</subject><subject>meters (equipment)</subject><subject>optical plethysmography</subject><subject>Oximetry - veterinary</subject><subject>Regression Analysis</subject><subject>sows</subject><subject>Swine - physiology</subject><subject>Systole</subject><issn>0830-9000</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNptkctOwzAURLMAlVL4BIRXrIjkRx7OBglVvKRKLChry7FvWqMkDrYDlK_gkzFqxUNidRczOnNHs5dMMWc4rTDGB8mh908Y07KgbJJMOMZZnuFp8qFsN0hnvO2RbZDf-GBbo1DdWqvR4MD70QHqQH7dDvqAbB2k6UGj0Zt-hSQaxtYDsm-mgwDuHMleI20cqPDD-5dk-ugFH9YQzHsEevvqj5L9Rkbe8e7OkuX11XJ-my7ub-7ml4u0oTwPKcFlrgvIJeFZw6jEKlMly0kJlHJaMKCqobrOoMoV1mWjM44zzgvSZLQilM2Siy12GOsOtIrvONmKwZlOuo2w0oi_Sm_WYmVfBInwgpMIONsBnH0eYwnRGa-gbWMjO3pRFnleEFZF48nvpO-I3QRRP93qjbRCruIU4vGBYsIwKXmci7JPn8aP8g</recordid><startdate>19940401</startdate><enddate>19940401</enddate><creator>Caulkett, N.A</creator><creator>Duke, T</creator><creator>Bailey, J.V</creator><scope>FBQ</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>19940401</creationdate><title>comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows</title><author>Caulkett, N.A ; Duke, T ; Bailey, J.V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-f285t-1075d6e5a184f32a0c4c73517e228263e2cf2db4e95c0d7fd48048861f429123</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>anesthesia</topic><topic>Anesthesia, Epidural - veterinary</topic><topic>Animals</topic><topic>Blood Pressure</topic><topic>Blood Pressure Determination - methods</topic><topic>Blood Pressure Determination - veterinary</topic><topic>Female</topic><topic>metering</topic><topic>meters (equipment)</topic><topic>optical plethysmography</topic><topic>Oximetry - veterinary</topic><topic>Regression Analysis</topic><topic>sows</topic><topic>Swine - physiology</topic><topic>Systole</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Caulkett, N.A</creatorcontrib><creatorcontrib>Duke, T</creatorcontrib><creatorcontrib>Bailey, J.V</creatorcontrib><collection>AGRIS</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Canadian journal of veterinary research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Caulkett, N.A</au><au>Duke, T</au><au>Bailey, J.V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows</atitle><jtitle>Canadian journal of veterinary research</jtitle><addtitle>Can J Vet Res</addtitle><date>1994-04-01</date><risdate>1994</risdate><volume>58</volume><issue>2</issue><spage>144</spage><epage>147</epage><pages>144-147</pages><issn>0830-9000</issn><abstract>Systolic blood pressure measurement obtained with a pulse oximeter has been compared to values obtained by other indirect methods in man. Direct pressure measurement is subject to less error than indirect techniques. This study was designed to compare systolic pressure values obtained using a pulse oximeter, with values obtained by direct arterial pressure measurement. The pulse oximeter waveform was used as an indication of perfusion. A blood pressure cuff was applied proximal to the pulse oximeter probe. The cuff was inflated until the oximeter waveform disappeared, this value was recorded as the systolic pressure at the disappearance of the waveform (SPD). The cuff was inflated to a pressure &gt; 200 mmHg, then gradually deflated until the waveform reappeared, this value was recorded as the systolic pressure at reappearance of the waveform (SPR). The average of the two values, SPD and SPR, was calculated and recorded as SPA. The study was performed in sows (n = 21) undergoing cesarean section under epidural anesthesia and IV sedation. A total of 280 measurements were made of SPD, SPR and SPA. Regression analysis of SPA and direct measurement revealed a correlation coefficient (r) of 0.81. Calculation of mean difference (bias) and standard deviation of the bias (precision) for direct pressure--SPA revealed a value of 1.3 +/- 12.1. When compared with direct measurement, the correlation of this technique was similar to that recorded for other indirect techniques used in small animals. This indicates that this technique would be useful for following systolic pressure trends.</abstract><cop>Canada</cop><pmid>8004540</pmid><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0830-9000
ispartof Canadian journal of veterinary research, 1994-04, Vol.58 (2), p.144-147
issn 0830-9000
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1263681
source PubMed Central Free
subjects anesthesia
Anesthesia, Epidural - veterinary
Animals
Blood Pressure
Blood Pressure Determination - methods
Blood Pressure Determination - veterinary
Female
metering
meters (equipment)
optical plethysmography
Oximetry - veterinary
Regression Analysis
sows
Swine - physiology
Systole
title comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T08%3A21%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=comparison%20of%20systolic%20blood%20pressure%20measurement%20obtained%20using%20a%20pulse%20oximeter,%20and%20direct%20systolic%20pressure%20measurement%20in%20anesthetized%20sows&rft.jtitle=Canadian%20journal%20of%20veterinary%20research&rft.au=Caulkett,%20N.A&rft.date=1994-04-01&rft.volume=58&rft.issue=2&rft.spage=144&rft.epage=147&rft.pages=144-147&rft.issn=0830-9000&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E76556139%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-f285t-1075d6e5a184f32a0c4c73517e228263e2cf2db4e95c0d7fd48048861f429123%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=76556139&rft_id=info:pmid/8004540&rfr_iscdi=true