Loading…

Implementing EPR dosimetry for life-threatening incidents: Factors beyond technical performance

Starting with the assumption that a device to detect unplanned radiation exposures is technically superior to current technology, we examine the additional stakeholders and processes that must be considered to move the device from the lab into use. The use is to provide reliable information to triag...

Full description

Saved in:
Bibliographic Details
Published in:Radiation measurements 2007-07, Vol.42 (6), p.1099-1109
Main Authors: Flood, Ann Barry, Bhattacharyya, Shayan, Javier Nicolalde, R., Swartz, Harold M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c563t-28be3350fa7c538b8700b426547963afa6c038610fd06efb49d5628738b7e88c3
cites cdi_FETCH-LOGICAL-c563t-28be3350fa7c538b8700b426547963afa6c038610fd06efb49d5628738b7e88c3
container_end_page 1109
container_issue 6
container_start_page 1099
container_title Radiation measurements
container_volume 42
creator Flood, Ann Barry
Bhattacharyya, Shayan
Javier Nicolalde, R.
Swartz, Harold M.
description Starting with the assumption that a device to detect unplanned radiation exposures is technically superior to current technology, we examine the additional stakeholders and processes that must be considered to move the device from the lab into use. The use is to provide reliable information to triage people for early treatment of exposure to ionizing radiation that could lead to the acute radiation syndrome. The scenario is a major accident or terrorist event that leaves a large number of people potentially exposed, with the resulting need to identify those to treat promptly or not. In vivo electron paramagnetic resonance (EPR) dosimetry is the exemplar of such a technique. Three major areas are reviewed: policy considerations, regulatory clearance, and production of the device. Our analysis of policy-making indicates that the current system is very complex, with multiple significant decision-makers who may have conflicting agendas. Adoption of new technologies by policy-makers is further complicated because many sources of expert input already have made public stances or have reasons to prefer current solutions, e.g., some may have conflicts of interest in approving new devices because they are involved with the development or adoption of competing techniques. Regulatory clearance is complicated by not being able to collect evidence via clinical trials of its intended use, but pathways for approval for emergency use are under development by the FDA. The production of the new device could be problematical if the perceived market is too limited, particularly for private manufacturers; for in vivo EPR dosimetry the potential for other uses may be a mitigating factor. Overall we conclude that technical superiority of a technique does not in itself assure its rapid and effective adoption, even where the need is great and the alternatives are not satisfactory for large populations. Many important steps remain to achieve the goals of approval and adoption for use.
doi_str_mv 10.1016/j.radmeas.2007.05.042
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2083703</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1350448707002338</els_id><sourcerecordid>1835464677</sourcerecordid><originalsourceid>FETCH-LOGICAL-c563t-28be3350fa7c538b8700b426547963afa6c038610fd06efb49d5628738b7e88c3</originalsourceid><addsrcrecordid>eNqFkV1rFDEYhQdRbK3-BGVuBG9mfDP59sIipdVCQRG9DpnMO90sM8mazBb235tlB6tXXiWQ55wczqmq1wRaAkS837bJDjPa3HYAsgXeAuueVOdESd2A7vjTcqccGsaUPKte5LwFAKYFf16dEcU10RrOK3M77yacMSw-3NfX377XQ8x-xiUd6jGmevIjNssmoV0wHBEfnB8Knj_UN9YtMeW6x0MMQ72g2wTv7FTvMBXtbIPDl9Wz0U4ZX63nRfXz5vrH1Zfm7uvn26tPd43jgi5Np3qkJe1opeNU9UoC9KwTnEktqB2tcECVIDAOIHDsmR646JQsqESlHL2oPp58d_t-xsGVhMlOZpf8bNPBROvNvy_Bb8x9fDAdKCqBFoN3q0GKv_aYFzP77HCabMC4z4YoyplgQsqC8hPqUsw54fjnGwLmOI7ZmnUccxzHADdlnKJ783fGR9W6RgHeroDNpccxlQZ9fuQ04ZJpVrjLE4el0QePyWTnsbQ9-IRuMUP0_4nyG4GHsfA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835464677</pqid></control><display><type>article</type><title>Implementing EPR dosimetry for life-threatening incidents: Factors beyond technical performance</title><source>Elsevier</source><creator>Flood, Ann Barry ; Bhattacharyya, Shayan ; Javier Nicolalde, R. ; Swartz, Harold M.</creator><creatorcontrib>Flood, Ann Barry ; Bhattacharyya, Shayan ; Javier Nicolalde, R. ; Swartz, Harold M.</creatorcontrib><description>Starting with the assumption that a device to detect unplanned radiation exposures is technically superior to current technology, we examine the additional stakeholders and processes that must be considered to move the device from the lab into use. The use is to provide reliable information to triage people for early treatment of exposure to ionizing radiation that could lead to the acute radiation syndrome. The scenario is a major accident or terrorist event that leaves a large number of people potentially exposed, with the resulting need to identify those to treat promptly or not. In vivo electron paramagnetic resonance (EPR) dosimetry is the exemplar of such a technique. Three major areas are reviewed: policy considerations, regulatory clearance, and production of the device. Our analysis of policy-making indicates that the current system is very complex, with multiple significant decision-makers who may have conflicting agendas. Adoption of new technologies by policy-makers is further complicated because many sources of expert input already have made public stances or have reasons to prefer current solutions, e.g., some may have conflicts of interest in approving new devices because they are involved with the development or adoption of competing techniques. Regulatory clearance is complicated by not being able to collect evidence via clinical trials of its intended use, but pathways for approval for emergency use are under development by the FDA. The production of the new device could be problematical if the perceived market is too limited, particularly for private manufacturers; for in vivo EPR dosimetry the potential for other uses may be a mitigating factor. Overall we conclude that technical superiority of a technique does not in itself assure its rapid and effective adoption, even where the need is great and the alternatives are not satisfactory for large populations. Many important steps remain to achieve the goals of approval and adoption for use.</description><identifier>ISSN: 1350-4487</identifier><identifier>EISSN: 1879-0925</identifier><identifier>DOI: 10.1016/j.radmeas.2007.05.042</identifier><identifier>PMID: 18591990</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Earth sciences ; Earth, ocean, space ; EPR dosimetry ; Exact sciences and technology ; Geochronology ; Internal geophysics ; Isotope geochemistry. Geochronology ; Physics ; Policy-making ; Radiation exposures ; Regulatory processes ; Triage</subject><ispartof>Radiation measurements, 2007-07, Vol.42 (6), p.1099-1109</ispartof><rights>2007 Elsevier Ltd</rights><rights>2007 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c563t-28be3350fa7c538b8700b426547963afa6c038610fd06efb49d5628738b7e88c3</citedby><cites>FETCH-LOGICAL-c563t-28be3350fa7c538b8700b426547963afa6c038610fd06efb49d5628738b7e88c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,309,310,314,776,780,785,786,881,23906,23907,25115,27898,27899</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=19157494$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18591990$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Flood, Ann Barry</creatorcontrib><creatorcontrib>Bhattacharyya, Shayan</creatorcontrib><creatorcontrib>Javier Nicolalde, R.</creatorcontrib><creatorcontrib>Swartz, Harold M.</creatorcontrib><title>Implementing EPR dosimetry for life-threatening incidents: Factors beyond technical performance</title><title>Radiation measurements</title><addtitle>Radiat Meas</addtitle><description>Starting with the assumption that a device to detect unplanned radiation exposures is technically superior to current technology, we examine the additional stakeholders and processes that must be considered to move the device from the lab into use. The use is to provide reliable information to triage people for early treatment of exposure to ionizing radiation that could lead to the acute radiation syndrome. The scenario is a major accident or terrorist event that leaves a large number of people potentially exposed, with the resulting need to identify those to treat promptly or not. In vivo electron paramagnetic resonance (EPR) dosimetry is the exemplar of such a technique. Three major areas are reviewed: policy considerations, regulatory clearance, and production of the device. Our analysis of policy-making indicates that the current system is very complex, with multiple significant decision-makers who may have conflicting agendas. Adoption of new technologies by policy-makers is further complicated because many sources of expert input already have made public stances or have reasons to prefer current solutions, e.g., some may have conflicts of interest in approving new devices because they are involved with the development or adoption of competing techniques. Regulatory clearance is complicated by not being able to collect evidence via clinical trials of its intended use, but pathways for approval for emergency use are under development by the FDA. The production of the new device could be problematical if the perceived market is too limited, particularly for private manufacturers; for in vivo EPR dosimetry the potential for other uses may be a mitigating factor. Overall we conclude that technical superiority of a technique does not in itself assure its rapid and effective adoption, even where the need is great and the alternatives are not satisfactory for large populations. Many important steps remain to achieve the goals of approval and adoption for use.</description><subject>Earth sciences</subject><subject>Earth, ocean, space</subject><subject>EPR dosimetry</subject><subject>Exact sciences and technology</subject><subject>Geochronology</subject><subject>Internal geophysics</subject><subject>Isotope geochemistry. Geochronology</subject><subject>Physics</subject><subject>Policy-making</subject><subject>Radiation exposures</subject><subject>Regulatory processes</subject><subject>Triage</subject><issn>1350-4487</issn><issn>1879-0925</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqFkV1rFDEYhQdRbK3-BGVuBG9mfDP59sIipdVCQRG9DpnMO90sM8mazBb235tlB6tXXiWQ55wczqmq1wRaAkS837bJDjPa3HYAsgXeAuueVOdESd2A7vjTcqccGsaUPKte5LwFAKYFf16dEcU10RrOK3M77yacMSw-3NfX377XQ8x-xiUd6jGmevIjNssmoV0wHBEfnB8Knj_UN9YtMeW6x0MMQ72g2wTv7FTvMBXtbIPDl9Wz0U4ZX63nRfXz5vrH1Zfm7uvn26tPd43jgi5Np3qkJe1opeNU9UoC9KwTnEktqB2tcECVIDAOIHDsmR646JQsqESlHL2oPp58d_t-xsGVhMlOZpf8bNPBROvNvy_Bb8x9fDAdKCqBFoN3q0GKv_aYFzP77HCabMC4z4YoyplgQsqC8hPqUsw54fjnGwLmOI7ZmnUccxzHADdlnKJ783fGR9W6RgHeroDNpccxlQZ9fuQ04ZJpVrjLE4el0QePyWTnsbQ9-IRuMUP0_4nyG4GHsfA</recordid><startdate>20070701</startdate><enddate>20070701</enddate><creator>Flood, Ann Barry</creator><creator>Bhattacharyya, Shayan</creator><creator>Javier Nicolalde, R.</creator><creator>Swartz, Harold M.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20070701</creationdate><title>Implementing EPR dosimetry for life-threatening incidents: Factors beyond technical performance</title><author>Flood, Ann Barry ; Bhattacharyya, Shayan ; Javier Nicolalde, R. ; Swartz, Harold M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c563t-28be3350fa7c538b8700b426547963afa6c038610fd06efb49d5628738b7e88c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Earth sciences</topic><topic>Earth, ocean, space</topic><topic>EPR dosimetry</topic><topic>Exact sciences and technology</topic><topic>Geochronology</topic><topic>Internal geophysics</topic><topic>Isotope geochemistry. Geochronology</topic><topic>Physics</topic><topic>Policy-making</topic><topic>Radiation exposures</topic><topic>Regulatory processes</topic><topic>Triage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Flood, Ann Barry</creatorcontrib><creatorcontrib>Bhattacharyya, Shayan</creatorcontrib><creatorcontrib>Javier Nicolalde, R.</creatorcontrib><creatorcontrib>Swartz, Harold M.</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Radiation measurements</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Flood, Ann Barry</au><au>Bhattacharyya, Shayan</au><au>Javier Nicolalde, R.</au><au>Swartz, Harold M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Implementing EPR dosimetry for life-threatening incidents: Factors beyond technical performance</atitle><jtitle>Radiation measurements</jtitle><addtitle>Radiat Meas</addtitle><date>2007-07-01</date><risdate>2007</risdate><volume>42</volume><issue>6</issue><spage>1099</spage><epage>1109</epage><pages>1099-1109</pages><issn>1350-4487</issn><eissn>1879-0925</eissn><abstract>Starting with the assumption that a device to detect unplanned radiation exposures is technically superior to current technology, we examine the additional stakeholders and processes that must be considered to move the device from the lab into use. The use is to provide reliable information to triage people for early treatment of exposure to ionizing radiation that could lead to the acute radiation syndrome. The scenario is a major accident or terrorist event that leaves a large number of people potentially exposed, with the resulting need to identify those to treat promptly or not. In vivo electron paramagnetic resonance (EPR) dosimetry is the exemplar of such a technique. Three major areas are reviewed: policy considerations, regulatory clearance, and production of the device. Our analysis of policy-making indicates that the current system is very complex, with multiple significant decision-makers who may have conflicting agendas. Adoption of new technologies by policy-makers is further complicated because many sources of expert input already have made public stances or have reasons to prefer current solutions, e.g., some may have conflicts of interest in approving new devices because they are involved with the development or adoption of competing techniques. Regulatory clearance is complicated by not being able to collect evidence via clinical trials of its intended use, but pathways for approval for emergency use are under development by the FDA. The production of the new device could be problematical if the perceived market is too limited, particularly for private manufacturers; for in vivo EPR dosimetry the potential for other uses may be a mitigating factor. Overall we conclude that technical superiority of a technique does not in itself assure its rapid and effective adoption, even where the need is great and the alternatives are not satisfactory for large populations. Many important steps remain to achieve the goals of approval and adoption for use.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><pmid>18591990</pmid><doi>10.1016/j.radmeas.2007.05.042</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1350-4487
ispartof Radiation measurements, 2007-07, Vol.42 (6), p.1099-1109
issn 1350-4487
1879-0925
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2083703
source Elsevier
subjects Earth sciences
Earth, ocean, space
EPR dosimetry
Exact sciences and technology
Geochronology
Internal geophysics
Isotope geochemistry. Geochronology
Physics
Policy-making
Radiation exposures
Regulatory processes
Triage
title Implementing EPR dosimetry for life-threatening incidents: Factors beyond technical performance
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-25T19%3A46%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Implementing%20EPR%20dosimetry%20for%20life-threatening%20incidents:%20Factors%20beyond%20technical%20performance&rft.jtitle=Radiation%20measurements&rft.au=Flood,%20Ann%20Barry&rft.date=2007-07-01&rft.volume=42&rft.issue=6&rft.spage=1099&rft.epage=1109&rft.pages=1099-1109&rft.issn=1350-4487&rft.eissn=1879-0925&rft_id=info:doi/10.1016/j.radmeas.2007.05.042&rft_dat=%3Cproquest_pubme%3E1835464677%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c563t-28be3350fa7c538b8700b426547963afa6c038610fd06efb49d5628738b7e88c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1835464677&rft_id=info:pmid/18591990&rfr_iscdi=true