Loading…

Application of a column selection system and DryLab software for high-performance liquid chromatography method development

This paper describes a strategy for the development of chromatographic methods for drug candidates based upon the use of simple MS compatible mobile phases and optimization of the chromatographic selectivity through variations of the stationary phase and mobile phase pH. The strategy employs an auto...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Chromatography A 2006-07, Vol.1122 (1), p.186-193
Main Authors: Krisko, Ryan M., McLaughlin, Kieran, Koenigbauer, Michael J., Lunte, Craig E.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c542t-421c5ab30a96bbf928f3cc9d0bfe848ade43d20f130b641c98a87f6c5cefd83e3
cites cdi_FETCH-LOGICAL-c542t-421c5ab30a96bbf928f3cc9d0bfe848ade43d20f130b641c98a87f6c5cefd83e3
container_end_page 193
container_issue 1
container_start_page 186
container_title Journal of Chromatography A
container_volume 1122
creator Krisko, Ryan M.
McLaughlin, Kieran
Koenigbauer, Michael J.
Lunte, Craig E.
description This paper describes a strategy for the development of chromatographic methods for drug candidates based upon the use of simple MS compatible mobile phases and optimization of the chromatographic selectivity through variations of the stationary phase and mobile phase pH. The strategy employs an automated column selection system and a series of HPLC columns, varying in hydrophobicity and silanol activity, in combination with DryLab software to develop chromatographic methods for the separation of mixtures of bupivacaine and its metabolites; acidic, basic, and neutral compounds; and atenolol, nitrendipine, and their degradation products.
doi_str_mv 10.1016/j.chroma.2006.04.065
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2519830</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021967306008934</els_id><sourcerecordid>68617694</sourcerecordid><originalsourceid>FETCH-LOGICAL-c542t-421c5ab30a96bbf928f3cc9d0bfe848ade43d20f130b641c98a87f6c5cefd83e3</originalsourceid><addsrcrecordid>eNp9kU-P0zAQxXMAscvCN0DIF7gl2E7ixBek1fJXqsQFztbEHjeunDhrp12VT4-XVhQunGx53sw8v19RvGK0YpSJd7tKjzFMUHFKRUWbior2SXFNKWelFF19VTxPaUcp62jHnxVXTHSM94JdFz9vl8U7DasLMwmWANHB76eZJPSof7-mY1pxIjAb8iEeNzCQFOz6ABGJDZGMbjuWC8Z8n2DWSLy73ztDTo7WsI2wjEcy4ToGQwwe0Idlwnl9UTy14BO-PJ83xY9PH7_ffSk33z5_vbvdlLpt-Fo2nOkWhpqCFMNgJe9trbU0dLDYNz0YbGrDqWU1HUTDtOyh76zQrUZr-hrrm-L9ae6yHyY0Oq-O4NUS3QTxqAI49W9ldqPahoPiLZN9TfOAt-cBMdzvMa1qckmj9zBj2CclcpKdkE0WNiehjiGliPbPEkbVIyi1U6dY1CMoRRuVQeW2138bvDSdKWXBm7MAkgZvY87ZpYuuk1zKll1-ijnOg8OoknaYmRgXM0xlgvu_k18GxrqY</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68617694</pqid></control><display><type>article</type><title>Application of a column selection system and DryLab software for high-performance liquid chromatography method development</title><source>ScienceDirect Journals</source><creator>Krisko, Ryan M. ; McLaughlin, Kieran ; Koenigbauer, Michael J. ; Lunte, Craig E.</creator><creatorcontrib>Krisko, Ryan M. ; McLaughlin, Kieran ; Koenigbauer, Michael J. ; Lunte, Craig E.</creatorcontrib><description>This paper describes a strategy for the development of chromatographic methods for drug candidates based upon the use of simple MS compatible mobile phases and optimization of the chromatographic selectivity through variations of the stationary phase and mobile phase pH. The strategy employs an automated column selection system and a series of HPLC columns, varying in hydrophobicity and silanol activity, in combination with DryLab software to develop chromatographic methods for the separation of mixtures of bupivacaine and its metabolites; acidic, basic, and neutral compounds; and atenolol, nitrendipine, and their degradation products.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/j.chroma.2006.04.065</identifier><identifier>PMID: 16712861</identifier><identifier>CODEN: JOCRAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analysis ; Atenolol - analysis ; Atenolol - chemistry ; Automated method development ; Biological and medical sciences ; Bupivacaine - analysis ; Bupivacaine - chemistry ; Chromatography, High Pressure Liquid - instrumentation ; Chromatography, High Pressure Liquid - methods ; Computer Simulation ; Drug Stability ; DryLab ; General pharmacology ; HPLC ; Hydrogen-Ion Concentration ; Mass Spectrometry - methods ; Medical sciences ; Pharmaceutical Preparations - analysis ; Pharmaceutical Preparations - chemistry ; Pharmacology. Drug treatments ; Reproducibility of Results ; Software ; Spectrophotometry, Ultraviolet - methods ; Stereoisomerism</subject><ispartof>Journal of Chromatography A, 2006-07, Vol.1122 (1), p.186-193</ispartof><rights>2006 Elsevier B.V.</rights><rights>2006 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c542t-421c5ab30a96bbf928f3cc9d0bfe848ade43d20f130b641c98a87f6c5cefd83e3</citedby><cites>FETCH-LOGICAL-c542t-421c5ab30a96bbf928f3cc9d0bfe848ade43d20f130b641c98a87f6c5cefd83e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=17929951$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16712861$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Krisko, Ryan M.</creatorcontrib><creatorcontrib>McLaughlin, Kieran</creatorcontrib><creatorcontrib>Koenigbauer, Michael J.</creatorcontrib><creatorcontrib>Lunte, Craig E.</creatorcontrib><title>Application of a column selection system and DryLab software for high-performance liquid chromatography method development</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>This paper describes a strategy for the development of chromatographic methods for drug candidates based upon the use of simple MS compatible mobile phases and optimization of the chromatographic selectivity through variations of the stationary phase and mobile phase pH. The strategy employs an automated column selection system and a series of HPLC columns, varying in hydrophobicity and silanol activity, in combination with DryLab software to develop chromatographic methods for the separation of mixtures of bupivacaine and its metabolites; acidic, basic, and neutral compounds; and atenolol, nitrendipine, and their degradation products.</description><subject>Analysis</subject><subject>Atenolol - analysis</subject><subject>Atenolol - chemistry</subject><subject>Automated method development</subject><subject>Biological and medical sciences</subject><subject>Bupivacaine - analysis</subject><subject>Bupivacaine - chemistry</subject><subject>Chromatography, High Pressure Liquid - instrumentation</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Computer Simulation</subject><subject>Drug Stability</subject><subject>DryLab</subject><subject>General pharmacology</subject><subject>HPLC</subject><subject>Hydrogen-Ion Concentration</subject><subject>Mass Spectrometry - methods</subject><subject>Medical sciences</subject><subject>Pharmaceutical Preparations - analysis</subject><subject>Pharmaceutical Preparations - chemistry</subject><subject>Pharmacology. Drug treatments</subject><subject>Reproducibility of Results</subject><subject>Software</subject><subject>Spectrophotometry, Ultraviolet - methods</subject><subject>Stereoisomerism</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNp9kU-P0zAQxXMAscvCN0DIF7gl2E7ixBek1fJXqsQFztbEHjeunDhrp12VT4-XVhQunGx53sw8v19RvGK0YpSJd7tKjzFMUHFKRUWbior2SXFNKWelFF19VTxPaUcp62jHnxVXTHSM94JdFz9vl8U7DasLMwmWANHB76eZJPSof7-mY1pxIjAb8iEeNzCQFOz6ABGJDZGMbjuWC8Z8n2DWSLy73ztDTo7WsI2wjEcy4ToGQwwe0Idlwnl9UTy14BO-PJ83xY9PH7_ffSk33z5_vbvdlLpt-Fo2nOkWhpqCFMNgJe9trbU0dLDYNz0YbGrDqWU1HUTDtOyh76zQrUZr-hrrm-L9ae6yHyY0Oq-O4NUS3QTxqAI49W9ldqPahoPiLZN9TfOAt-cBMdzvMa1qckmj9zBj2CclcpKdkE0WNiehjiGliPbPEkbVIyi1U6dY1CMoRRuVQeW2138bvDSdKWXBm7MAkgZvY87ZpYuuk1zKll1-ijnOg8OoknaYmRgXM0xlgvu_k18GxrqY</recordid><startdate>20060728</startdate><enddate>20060728</enddate><creator>Krisko, Ryan M.</creator><creator>McLaughlin, Kieran</creator><creator>Koenigbauer, Michael J.</creator><creator>Lunte, Craig E.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20060728</creationdate><title>Application of a column selection system and DryLab software for high-performance liquid chromatography method development</title><author>Krisko, Ryan M. ; McLaughlin, Kieran ; Koenigbauer, Michael J. ; Lunte, Craig E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c542t-421c5ab30a96bbf928f3cc9d0bfe848ade43d20f130b641c98a87f6c5cefd83e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Analysis</topic><topic>Atenolol - analysis</topic><topic>Atenolol - chemistry</topic><topic>Automated method development</topic><topic>Biological and medical sciences</topic><topic>Bupivacaine - analysis</topic><topic>Bupivacaine - chemistry</topic><topic>Chromatography, High Pressure Liquid - instrumentation</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Computer Simulation</topic><topic>Drug Stability</topic><topic>DryLab</topic><topic>General pharmacology</topic><topic>HPLC</topic><topic>Hydrogen-Ion Concentration</topic><topic>Mass Spectrometry - methods</topic><topic>Medical sciences</topic><topic>Pharmaceutical Preparations - analysis</topic><topic>Pharmaceutical Preparations - chemistry</topic><topic>Pharmacology. Drug treatments</topic><topic>Reproducibility of Results</topic><topic>Software</topic><topic>Spectrophotometry, Ultraviolet - methods</topic><topic>Stereoisomerism</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Krisko, Ryan M.</creatorcontrib><creatorcontrib>McLaughlin, Kieran</creatorcontrib><creatorcontrib>Koenigbauer, Michael J.</creatorcontrib><creatorcontrib>Lunte, Craig E.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Krisko, Ryan M.</au><au>McLaughlin, Kieran</au><au>Koenigbauer, Michael J.</au><au>Lunte, Craig E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of a column selection system and DryLab software for high-performance liquid chromatography method development</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2006-07-28</date><risdate>2006</risdate><volume>1122</volume><issue>1</issue><spage>186</spage><epage>193</epage><pages>186-193</pages><issn>0021-9673</issn><coden>JOCRAM</coden><abstract>This paper describes a strategy for the development of chromatographic methods for drug candidates based upon the use of simple MS compatible mobile phases and optimization of the chromatographic selectivity through variations of the stationary phase and mobile phase pH. The strategy employs an automated column selection system and a series of HPLC columns, varying in hydrophobicity and silanol activity, in combination with DryLab software to develop chromatographic methods for the separation of mixtures of bupivacaine and its metabolites; acidic, basic, and neutral compounds; and atenolol, nitrendipine, and their degradation products.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>16712861</pmid><doi>10.1016/j.chroma.2006.04.065</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2006-07, Vol.1122 (1), p.186-193
issn 0021-9673
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2519830
source ScienceDirect Journals
subjects Analysis
Atenolol - analysis
Atenolol - chemistry
Automated method development
Biological and medical sciences
Bupivacaine - analysis
Bupivacaine - chemistry
Chromatography, High Pressure Liquid - instrumentation
Chromatography, High Pressure Liquid - methods
Computer Simulation
Drug Stability
DryLab
General pharmacology
HPLC
Hydrogen-Ion Concentration
Mass Spectrometry - methods
Medical sciences
Pharmaceutical Preparations - analysis
Pharmaceutical Preparations - chemistry
Pharmacology. Drug treatments
Reproducibility of Results
Software
Spectrophotometry, Ultraviolet - methods
Stereoisomerism
title Application of a column selection system and DryLab software for high-performance liquid chromatography method development
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T21%3A56%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%20a%20column%20selection%20system%20and%20DryLab%20software%20for%20high-performance%20liquid%20chromatography%20method%20development&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Krisko,%20Ryan%20M.&rft.date=2006-07-28&rft.volume=1122&rft.issue=1&rft.spage=186&rft.epage=193&rft.pages=186-193&rft.issn=0021-9673&rft.coden=JOCRAM&rft_id=info:doi/10.1016/j.chroma.2006.04.065&rft_dat=%3Cproquest_pubme%3E68617694%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c542t-421c5ab30a96bbf928f3cc9d0bfe848ade43d20f130b641c98a87f6c5cefd83e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=68617694&rft_id=info:pmid/16712861&rfr_iscdi=true