Loading…

Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis

Abstract Background This study investigated the stiffness and strength of bridge plating with uni-cortical and bi-cortical locking plate constructs relative to a conventional, non-locked construct in the osteoporotic femoral diaphysis. Methods Four bridge plating configurations were applied to a val...

Full description

Saved in:
Bibliographic Details
Published in:Clinical biomechanics (Bristol) 2009-02, Vol.24 (2), p.203-209
Main Authors: Fitzpatrick, Daniel C, Doornink, Josef, Madey, Steven M, Bottlang, Michael
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Background This study investigated the stiffness and strength of bridge plating with uni-cortical and bi-cortical locking plate constructs relative to a conventional, non-locked construct in the osteoporotic femoral diaphysis. Methods Four bridge plating configurations were applied to a validated model of the osteoporotic femoral diaphysis. A non-locked conventional configuration served as baseline. Locked configurations included bi-cortical locked plating, uni-cortical locked plating and mix-mode locked plating, which combined uni and bi-cortical locking screws. For all configurations, an 11-hole plate was applied with 4.5-mm screws placed in the 1st, 3rd, and 5th plate hole. Five specimens of each configuration were dynamically loaded until failure in torsion, axial compression, and bending to determine construct stiffness, strength and failure modes. Findings In torsion and bending, locked plating constructs provided a significantly lower stiffness and strength than the conventional construct. The uni-cortical locked construct was 69% weaker ( P < 0.001) in torsion than the conventional construct, but its torsional strength improved 73% ( P < 0.001) by adding one bi-cortical locked screw. In axial compression, construct stiffness varied by less than 10% between the four groups. However, the bi-cortical and mixed-mode locked constructs provided a significant increase in strength of 12% ( P = 0.001) and 11% ( P = 0.002), respectively, compared to the conventional construct. Interpretations Locked plating in the osteoporotic diaphysis can improve fixation strength under axial loading, but may reduce fixation strength in bending and torsion compared to conventional plating. Adding one bi-cortical locked screw to an otherwise uni-cortical construct is recommended to improve torsional strength.
ISSN:0268-0033
1879-1271
DOI:10.1016/j.clinbiomech.2008.11.002