Loading…

Internal fixation of proximal humeral fractures with locking proximal humeral plate (LPHP) in elderly patients with osteoporosis

Background Different operative techniques used for treating displaced proximal humeral fractures could result in malunion, non-union, osteonecrosis of humeral head, loosening of screw and loss of reduction particularly in comminuted and osteoporotic fractures. Locking compression plate (LPHP) has be...

Full description

Saved in:
Bibliographic Details
Published in:Journal of orthopaedics and traumatology 2008-09, Vol.9 (3), p.149-153
Main Authors: Siwach, Ramchander, Singh, Roop, Rohilla, Rajesh Kumar, Kadian, Virender Singh, Sangwan, Sukhbir Singh, Dhanda, Manjeet
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Different operative techniques used for treating displaced proximal humeral fractures could result in malunion, non-union, osteonecrosis of humeral head, loosening of screw and loss of reduction particularly in comminuted and osteoporotic fractures. Locking compression plate (LPHP) has been proposed for open reduction and internal fixation of these fractures and is associated with less complication rate. Materials and methods We prospectively assessed the functional outcome and the complications after an average follow-up of 24.9 months in 25 patients of proximal humeral fractures with osteoporosis. Mean age was 62 years. Using AO classification, 48% were type A and 52% type B. Results Mean constant score was 80 points. According to constant score, 28% had excellent outcome, 64% had good functional outcome, and 8% had moderate outcome. When the results were related to grades of osteoporosis, grade IV osteoporotic fractures had highest average Constant–Murley score (83 points, range 78–88 points), followed by grade III osteoporotic fractures (80 points, range 71–92 points), followed by grade II osteoporotic fractures (78 points, range 66–88 points). Varus malalignment and subacromial impingement were observed in 8% patients. Loosening of implant and loss of reduction were observed in 4% patients. Superficial infection was observed in 4% patients. Conclusions Locking compression plate (LPHP) is an advantageous implant in proximal humeral fractures due to angular stability, particularly in comminuted fractures and in osteoporotic bones in elderly patients, thus allowing early mobilization.
ISSN:1590-9921
1590-9999
DOI:10.1007/s10195-008-0014-6