Loading…

Influence of biologically inspired nanometer surface roughness on antigen-antibody interactions for immunoassay-biosensor applications

Current research efforts to improve immunoassay-biosensor functionality have centered on detection through the optimal design of microfluidic chambers, electrical circuitry, optical sensing elements, and so on. To date, little attention has been paid to the immunoassay-biosensor membrane surface on...

Full description

Saved in:
Bibliographic Details
Published in:International journal of nanomedicine 2006-12, Vol.1 (4), p.497-505
Main Authors: Tuttle, 4th, Paul V, Rundell, Ann E, Webster, Thomas J
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3367-27dda58716cdcb13720764948f5ce96d0558641f4390ff1b422a0f57cf57510e3
cites cdi_FETCH-LOGICAL-c3367-27dda58716cdcb13720764948f5ce96d0558641f4390ff1b422a0f57cf57510e3
container_end_page 505
container_issue 4
container_start_page 497
container_title International journal of nanomedicine
container_volume 1
creator Tuttle, 4th, Paul V
Rundell, Ann E
Webster, Thomas J
description Current research efforts to improve immunoassay-biosensor functionality have centered on detection through the optimal design of microfluidic chambers, electrical circuitry, optical sensing elements, and so on. To date, little attention has been paid to the immunoassay-biosensor membrane surface on which interactions between antibodies and antigens must occur. For this reason, the objective of the present study was to manipulate the nanometer surface roughness of a model immunoassay-biosensor membrane to determine its role on sensitivity and specificity. It was hypothesized that surface roughness characteristics similar to those used by the body's own immune system with B-lymphocyte cell membranes would promote antigen-antibody interactions and minimize non-specific binding. To test this hypothesis, polystyrene 96-well plate surfaces were modified to possess similar topographies as those of B-lymphocyte cell membranes. This was accomplished by immobilizing Protein A conjugated gold particles and Protein A conjugated polystyrene particles ranging in sizes from 40 to 860 nm to the bottom of polystyrene wells. Atomic force microscopy results provided evidence of well-dispersed immunoassay-biosensor surfaces for all particles tested with high degrees of biologically inspired nanometer roughness. Testing the functionality of these immunosurfaces using antigenic fluorescent microspheres showed that specific antigen capture increased with greater nanometer surface roughness while nonspecific antigen capture did not correlate with surface roughness. In this manner, results from this study suggest that large degrees of biologically inspired nanometer surface roughness not only increases the amount of immobilized antibodies onto the immunosurface membrane, but it also enhances the functionality of those antibodies for optimal antigen capture, criteria critical for improving immunoassay-biosensor sensitivity and specificity.
doi_str_mv 10.2147/nano.2006.1.4.497
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2676634</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2222566201</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3367-27dda58716cdcb13720764948f5ce96d0558641f4390ff1b422a0f57cf57510e3</originalsourceid><addsrcrecordid>eNpVUctq3DAUFaGlSab9gGyKoGu7urIs2ZtCCHlBoJt2LWRZmlGwJVeyA_MD-e7KM0OaLsQV0nlczkHoCkhJgYnvXvlQUkJ4CSUrWSvO0AWAaApKoPpwuPOiBWDn6DKlZ0Jq0fD2EzoHISilDb1Ar4_eDovx2uBgcefCELZOq2HYY-fT5KLp8WozmtlEnJZoVYbGsGx33qSEg8fKz25rfLHOLvQrMWOVnl3wCdsQsRvHxQeVktoX2SIZn_KrmqYhWx1gn9FHq4ZkvpzmBv2-u_1181A8_bx_vLl-KnRVcVFQ0feqbgRw3esOKkGJ4Kxlja21aXlP6rrhDCyrWmItdIxSRWwtdD41EFNt0I-j7rR0o-m18XNUg5yiG1Xcy6Cc_P_Hu53chhdJueC8Ylng20kghj-LSbN8Dkv0eWeZE6U152v2GwRHlI4hpWjsmwMQuVYn10zlWp0EyWSuLnO-vl_tH-PUVfUXNVuaZQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2222566201</pqid></control><display><type>article</type><title>Influence of biologically inspired nanometer surface roughness on antigen-antibody interactions for immunoassay-biosensor applications</title><source>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</source><source>Taylor &amp; Francis_OA刊</source><source>PubMed Central</source><creator>Tuttle, 4th, Paul V ; Rundell, Ann E ; Webster, Thomas J</creator><creatorcontrib>Tuttle, 4th, Paul V ; Rundell, Ann E ; Webster, Thomas J</creatorcontrib><description>Current research efforts to improve immunoassay-biosensor functionality have centered on detection through the optimal design of microfluidic chambers, electrical circuitry, optical sensing elements, and so on. To date, little attention has been paid to the immunoassay-biosensor membrane surface on which interactions between antibodies and antigens must occur. For this reason, the objective of the present study was to manipulate the nanometer surface roughness of a model immunoassay-biosensor membrane to determine its role on sensitivity and specificity. It was hypothesized that surface roughness characteristics similar to those used by the body's own immune system with B-lymphocyte cell membranes would promote antigen-antibody interactions and minimize non-specific binding. To test this hypothesis, polystyrene 96-well plate surfaces were modified to possess similar topographies as those of B-lymphocyte cell membranes. This was accomplished by immobilizing Protein A conjugated gold particles and Protein A conjugated polystyrene particles ranging in sizes from 40 to 860 nm to the bottom of polystyrene wells. Atomic force microscopy results provided evidence of well-dispersed immunoassay-biosensor surfaces for all particles tested with high degrees of biologically inspired nanometer roughness. Testing the functionality of these immunosurfaces using antigenic fluorescent microspheres showed that specific antigen capture increased with greater nanometer surface roughness while nonspecific antigen capture did not correlate with surface roughness. In this manner, results from this study suggest that large degrees of biologically inspired nanometer surface roughness not only increases the amount of immobilized antibodies onto the immunosurface membrane, but it also enhances the functionality of those antibodies for optimal antigen capture, criteria critical for improving immunoassay-biosensor sensitivity and specificity.</description><identifier>ISSN: 1176-9114</identifier><identifier>EISSN: 1178-2013</identifier><identifier>DOI: 10.2147/nano.2006.1.4.497</identifier><identifier>PMID: 17722282</identifier><language>eng</language><publisher>New Zealand: Taylor &amp; Francis Ltd</publisher><subject>Antigen-Antibody Complex - analysis ; Antigen-Antibody Complex - immunology ; Antigen-Antibody Reactions - immunology ; Antigens ; B-Lymphocytes - immunology ; Biological Assay - methods ; Biosensing Techniques - methods ; Biosensors ; Humans ; Immunoassay ; Immunoassay - methods ; Immunoglobulins ; Nanostructures - chemistry ; Nanostructures - ultrastructure ; Original Research ; Sensitivity and Specificity ; Surface Properties</subject><ispartof>International journal of nanomedicine, 2006-12, Vol.1 (4), p.497-505</ispartof><rights>Copyright Taylor &amp; Francis Ltd. 2006</rights><rights>2006 Dove Medical Press Limited. All rights reserved 2006</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3367-27dda58716cdcb13720764948f5ce96d0558641f4390ff1b422a0f57cf57510e3</citedby><cites>FETCH-LOGICAL-c3367-27dda58716cdcb13720764948f5ce96d0558641f4390ff1b422a0f57cf57510e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2222566201/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2222566201?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,25731,27901,27902,36989,44566,53766,53768,74869</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17722282$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tuttle, 4th, Paul V</creatorcontrib><creatorcontrib>Rundell, Ann E</creatorcontrib><creatorcontrib>Webster, Thomas J</creatorcontrib><title>Influence of biologically inspired nanometer surface roughness on antigen-antibody interactions for immunoassay-biosensor applications</title><title>International journal of nanomedicine</title><addtitle>Int J Nanomedicine</addtitle><description>Current research efforts to improve immunoassay-biosensor functionality have centered on detection through the optimal design of microfluidic chambers, electrical circuitry, optical sensing elements, and so on. To date, little attention has been paid to the immunoassay-biosensor membrane surface on which interactions between antibodies and antigens must occur. For this reason, the objective of the present study was to manipulate the nanometer surface roughness of a model immunoassay-biosensor membrane to determine its role on sensitivity and specificity. It was hypothesized that surface roughness characteristics similar to those used by the body's own immune system with B-lymphocyte cell membranes would promote antigen-antibody interactions and minimize non-specific binding. To test this hypothesis, polystyrene 96-well plate surfaces were modified to possess similar topographies as those of B-lymphocyte cell membranes. This was accomplished by immobilizing Protein A conjugated gold particles and Protein A conjugated polystyrene particles ranging in sizes from 40 to 860 nm to the bottom of polystyrene wells. Atomic force microscopy results provided evidence of well-dispersed immunoassay-biosensor surfaces for all particles tested with high degrees of biologically inspired nanometer roughness. Testing the functionality of these immunosurfaces using antigenic fluorescent microspheres showed that specific antigen capture increased with greater nanometer surface roughness while nonspecific antigen capture did not correlate with surface roughness. In this manner, results from this study suggest that large degrees of biologically inspired nanometer surface roughness not only increases the amount of immobilized antibodies onto the immunosurface membrane, but it also enhances the functionality of those antibodies for optimal antigen capture, criteria critical for improving immunoassay-biosensor sensitivity and specificity.</description><subject>Antigen-Antibody Complex - analysis</subject><subject>Antigen-Antibody Complex - immunology</subject><subject>Antigen-Antibody Reactions - immunology</subject><subject>Antigens</subject><subject>B-Lymphocytes - immunology</subject><subject>Biological Assay - methods</subject><subject>Biosensing Techniques - methods</subject><subject>Biosensors</subject><subject>Humans</subject><subject>Immunoassay</subject><subject>Immunoassay - methods</subject><subject>Immunoglobulins</subject><subject>Nanostructures - chemistry</subject><subject>Nanostructures - ultrastructure</subject><subject>Original Research</subject><subject>Sensitivity and Specificity</subject><subject>Surface Properties</subject><issn>1176-9114</issn><issn>1178-2013</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpVUctq3DAUFaGlSab9gGyKoGu7urIs2ZtCCHlBoJt2LWRZmlGwJVeyA_MD-e7KM0OaLsQV0nlczkHoCkhJgYnvXvlQUkJ4CSUrWSvO0AWAaApKoPpwuPOiBWDn6DKlZ0Jq0fD2EzoHISilDb1Ar4_eDovx2uBgcefCELZOq2HYY-fT5KLp8WozmtlEnJZoVYbGsGx33qSEg8fKz25rfLHOLvQrMWOVnl3wCdsQsRvHxQeVktoX2SIZn_KrmqYhWx1gn9FHq4ZkvpzmBv2-u_1181A8_bx_vLl-KnRVcVFQ0feqbgRw3esOKkGJ4Kxlja21aXlP6rrhDCyrWmItdIxSRWwtdD41EFNt0I-j7rR0o-m18XNUg5yiG1Xcy6Cc_P_Hu53chhdJueC8Ylng20kghj-LSbN8Dkv0eWeZE6U152v2GwRHlI4hpWjsmwMQuVYn10zlWp0EyWSuLnO-vl_tH-PUVfUXNVuaZQ</recordid><startdate>20061201</startdate><enddate>20061201</enddate><creator>Tuttle, 4th, Paul V</creator><creator>Rundell, Ann E</creator><creator>Webster, Thomas J</creator><general>Taylor &amp; Francis Ltd</general><general>Dove Medical Press</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>K9.</scope><scope>M0S</scope><scope>M2O</scope><scope>MBDVC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>5PM</scope></search><sort><creationdate>20061201</creationdate><title>Influence of biologically inspired nanometer surface roughness on antigen-antibody interactions for immunoassay-biosensor applications</title><author>Tuttle, 4th, Paul V ; Rundell, Ann E ; Webster, Thomas J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3367-27dda58716cdcb13720764948f5ce96d0558641f4390ff1b422a0f57cf57510e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Antigen-Antibody Complex - analysis</topic><topic>Antigen-Antibody Complex - immunology</topic><topic>Antigen-Antibody Reactions - immunology</topic><topic>Antigens</topic><topic>B-Lymphocytes - immunology</topic><topic>Biological Assay - methods</topic><topic>Biosensing Techniques - methods</topic><topic>Biosensors</topic><topic>Humans</topic><topic>Immunoassay</topic><topic>Immunoassay - methods</topic><topic>Immunoglobulins</topic><topic>Nanostructures - chemistry</topic><topic>Nanostructures - ultrastructure</topic><topic>Original Research</topic><topic>Sensitivity and Specificity</topic><topic>Surface Properties</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tuttle, 4th, Paul V</creatorcontrib><creatorcontrib>Rundell, Ann E</creatorcontrib><creatorcontrib>Webster, Thomas J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Proquest Health &amp; Medical Complete</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>ProQuest research library</collection><collection>Research Library (Corporate)</collection><collection>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>International journal of nanomedicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tuttle, 4th, Paul V</au><au>Rundell, Ann E</au><au>Webster, Thomas J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of biologically inspired nanometer surface roughness on antigen-antibody interactions for immunoassay-biosensor applications</atitle><jtitle>International journal of nanomedicine</jtitle><addtitle>Int J Nanomedicine</addtitle><date>2006-12-01</date><risdate>2006</risdate><volume>1</volume><issue>4</issue><spage>497</spage><epage>505</epage><pages>497-505</pages><issn>1176-9114</issn><eissn>1178-2013</eissn><abstract>Current research efforts to improve immunoassay-biosensor functionality have centered on detection through the optimal design of microfluidic chambers, electrical circuitry, optical sensing elements, and so on. To date, little attention has been paid to the immunoassay-biosensor membrane surface on which interactions between antibodies and antigens must occur. For this reason, the objective of the present study was to manipulate the nanometer surface roughness of a model immunoassay-biosensor membrane to determine its role on sensitivity and specificity. It was hypothesized that surface roughness characteristics similar to those used by the body's own immune system with B-lymphocyte cell membranes would promote antigen-antibody interactions and minimize non-specific binding. To test this hypothesis, polystyrene 96-well plate surfaces were modified to possess similar topographies as those of B-lymphocyte cell membranes. This was accomplished by immobilizing Protein A conjugated gold particles and Protein A conjugated polystyrene particles ranging in sizes from 40 to 860 nm to the bottom of polystyrene wells. Atomic force microscopy results provided evidence of well-dispersed immunoassay-biosensor surfaces for all particles tested with high degrees of biologically inspired nanometer roughness. Testing the functionality of these immunosurfaces using antigenic fluorescent microspheres showed that specific antigen capture increased with greater nanometer surface roughness while nonspecific antigen capture did not correlate with surface roughness. In this manner, results from this study suggest that large degrees of biologically inspired nanometer surface roughness not only increases the amount of immobilized antibodies onto the immunosurface membrane, but it also enhances the functionality of those antibodies for optimal antigen capture, criteria critical for improving immunoassay-biosensor sensitivity and specificity.</abstract><cop>New Zealand</cop><pub>Taylor &amp; Francis Ltd</pub><pmid>17722282</pmid><doi>10.2147/nano.2006.1.4.497</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1176-9114
ispartof International journal of nanomedicine, 2006-12, Vol.1 (4), p.497-505
issn 1176-9114
1178-2013
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2676634
source Publicly Available Content Database (Proquest) (PQ_SDU_P3); Taylor & Francis_OA刊; PubMed Central
subjects Antigen-Antibody Complex - analysis
Antigen-Antibody Complex - immunology
Antigen-Antibody Reactions - immunology
Antigens
B-Lymphocytes - immunology
Biological Assay - methods
Biosensing Techniques - methods
Biosensors
Humans
Immunoassay
Immunoassay - methods
Immunoglobulins
Nanostructures - chemistry
Nanostructures - ultrastructure
Original Research
Sensitivity and Specificity
Surface Properties
title Influence of biologically inspired nanometer surface roughness on antigen-antibody interactions for immunoassay-biosensor applications
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T14%3A33%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20biologically%20inspired%20nanometer%20surface%20roughness%20on%20antigen-antibody%20interactions%20for%20immunoassay-biosensor%20applications&rft.jtitle=International%20journal%20of%20nanomedicine&rft.au=Tuttle,%204th,%20Paul%20V&rft.date=2006-12-01&rft.volume=1&rft.issue=4&rft.spage=497&rft.epage=505&rft.pages=497-505&rft.issn=1176-9114&rft.eissn=1178-2013&rft_id=info:doi/10.2147/nano.2006.1.4.497&rft_dat=%3Cproquest_pubme%3E2222566201%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3367-27dda58716cdcb13720764948f5ce96d0558641f4390ff1b422a0f57cf57510e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2222566201&rft_id=info:pmid/17722282&rfr_iscdi=true