Uncommon presentation of a common tachycardia

We describe a patient with an implanted pacemaker for impaired AV conduction who presented with an incessant tachycardia. EP study showed that the tachycardia was atrioventricular nodal reentrant tachycardia (AVNRT) with repeated spontaneous initiation because of poor or absent antegrade fast pathwa...

Full description

Saved in:
Bibliographic Details
Published in:Indian pacing and electrophysiology journal 2010-09, Vol.10 (9), p.426-428
Main Authors: Selvaraj, Raja, Arunprasath, Palamalai, Karthikeyan, Balakrishnan, George, Geofi, Balachander, Jayaraman
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We describe a patient with an implanted pacemaker for impaired AV conduction who presented with an incessant tachycardia. EP study showed that the tachycardia was atrioventricular nodal reentrant tachycardia (AVNRT) with repeated spontaneous initiation because of poor or absent antegrade fast pathway conduction. Slow pathway ablation was successful in terminating the tachycardia and making it non-inducible.