Imaging skeletal muscle using second harmonic generation and coherent anti-Stokes Raman scattering microscopy

We describe experimental results on label free imaging of striated skeletal muscle using second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) microscopy. The complementarity of the SHG and CARS data makes it possible to clearly identify the main sarcomere sub-structures...

Full description

Saved in:
Bibliographic Details
Published in:Biomedical optics express 2011-05, Vol.2 (5), p.1366-1376
Main Authors: Pfeffer, Christian P, Olsen, Bjorn R, Ganikhanov, Feruz, Légaré, François
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c383t-d0de391f43a5ad333e4f97c452954f8283d057fd612a46d4b4b2047f037fe9b53
cites cdi_FETCH-LOGICAL-c383t-d0de391f43a5ad333e4f97c452954f8283d057fd612a46d4b4b2047f037fe9b53
container_end_page 1376
container_issue 5
container_start_page 1366
container_title Biomedical optics express
container_volume 2
creator Pfeffer, Christian P
Olsen, Bjorn R
Ganikhanov, Feruz
Légaré, François
description We describe experimental results on label free imaging of striated skeletal muscle using second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) microscopy. The complementarity of the SHG and CARS data makes it possible to clearly identify the main sarcomere sub-structures such as actin, myosin, acto-myosin, and the intact T-tubular system as it emanates from the sarcolemma. Owing to sub-micron spatial resolution and the high sensitivity of the CARS microscopy technique we were able to resolve individual myofibrils. In addition, key organelles such as mitochondria, cell nuclei and their structural constituents were observed revealing the entire structure of the muscle functional units. There is a noticeable difference in the CARS response of the muscle structure within actin, myosin and t-tubule areas with respect to laser polarization. We attribute this to a preferential alignment of the probed molecular bonds along certain directions. The combined CARS and SHG microscopy approach yields more extensive and complementary information and has a potential to become an indispensable method for live skeletal muscle characterization.
doi_str_mv 10.1364/BOE.2.001366
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3087593</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>866249441</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-d0de391f43a5ad333e4f97c452954f8283d057fd612a46d4b4b2047f037fe9b53</originalsourceid><addsrcrecordid>eNpVUU1LxDAQDaKorHvzLL15sWvaJP24CLr4BQsLfpxDmk670SZZk1Tw35t1VXQuM2_m8WaGh9BxhmcZKej51fJ6ls8wjqDYQYd5xoq0xBXb_VMfoKn3LzgGpSUm1T46iDNWZ7Q6RPpei16ZPvGvMEAQQ6JHLwdIRv_VBWlNm6yE09YomfRgwImgrElE7Eu7AgcmRBBU-hjsK_jkQWhhEi9FCOA2IlpJZ720648jtNeJwcP0O0_Q88310_wuXSxv7-eXi1SSioS0xS2QOusoEUy0hBCgXV1KyvKa0a7KK9JiVnZtkeWCFi1taJNjWnaYlB3UDSMTdLHVXY-NhlbGE50Y-NopLdwHt0Lx_xOjVry375zgqmQ1iQKn3wLOvo3gA9fKSxgGYcCOnldFkdOa0iwyz7bMzY_eQfe7JcN84xGPHvGcbz2K9JO_l_2Sfxwhn-OXjw4</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>866249441</pqid></control><display><type>article</type><title>Imaging skeletal muscle using second harmonic generation and coherent anti-Stokes Raman scattering microscopy</title><source>PubMed Central</source><source>EZB Electronic Journals Library</source><creator>Pfeffer, Christian P ; Olsen, Bjorn R ; Ganikhanov, Feruz ; Légaré, François</creator><creatorcontrib>Pfeffer, Christian P ; Olsen, Bjorn R ; Ganikhanov, Feruz ; Légaré, François</creatorcontrib><description>We describe experimental results on label free imaging of striated skeletal muscle using second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) microscopy. The complementarity of the SHG and CARS data makes it possible to clearly identify the main sarcomere sub-structures such as actin, myosin, acto-myosin, and the intact T-tubular system as it emanates from the sarcolemma. Owing to sub-micron spatial resolution and the high sensitivity of the CARS microscopy technique we were able to resolve individual myofibrils. In addition, key organelles such as mitochondria, cell nuclei and their structural constituents were observed revealing the entire structure of the muscle functional units. There is a noticeable difference in the CARS response of the muscle structure within actin, myosin and t-tubule areas with respect to laser polarization. We attribute this to a preferential alignment of the probed molecular bonds along certain directions. The combined CARS and SHG microscopy approach yields more extensive and complementary information and has a potential to become an indispensable method for live skeletal muscle characterization.</description><identifier>ISSN: 2156-7085</identifier><identifier>EISSN: 2156-7085</identifier><identifier>DOI: 10.1364/BOE.2.001366</identifier><identifier>PMID: 21559148</identifier><language>eng</language><publisher>United States: Optical Society of America</publisher><subject>Microscopy</subject><ispartof>Biomedical optics express, 2011-05, Vol.2 (5), p.1366-1376</ispartof><rights>2011 Optical Society of America 2011 OSA</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-d0de391f43a5ad333e4f97c452954f8283d057fd612a46d4b4b2047f037fe9b53</citedby><cites>FETCH-LOGICAL-c383t-d0de391f43a5ad333e4f97c452954f8283d057fd612a46d4b4b2047f037fe9b53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087593/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3087593/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27903,27904,53769,53771</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21559148$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pfeffer, Christian P</creatorcontrib><creatorcontrib>Olsen, Bjorn R</creatorcontrib><creatorcontrib>Ganikhanov, Feruz</creatorcontrib><creatorcontrib>Légaré, François</creatorcontrib><title>Imaging skeletal muscle using second harmonic generation and coherent anti-Stokes Raman scattering microscopy</title><title>Biomedical optics express</title><addtitle>Biomed Opt Express</addtitle><description>We describe experimental results on label free imaging of striated skeletal muscle using second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) microscopy. The complementarity of the SHG and CARS data makes it possible to clearly identify the main sarcomere sub-structures such as actin, myosin, acto-myosin, and the intact T-tubular system as it emanates from the sarcolemma. Owing to sub-micron spatial resolution and the high sensitivity of the CARS microscopy technique we were able to resolve individual myofibrils. In addition, key organelles such as mitochondria, cell nuclei and their structural constituents were observed revealing the entire structure of the muscle functional units. There is a noticeable difference in the CARS response of the muscle structure within actin, myosin and t-tubule areas with respect to laser polarization. We attribute this to a preferential alignment of the probed molecular bonds along certain directions. The combined CARS and SHG microscopy approach yields more extensive and complementary information and has a potential to become an indispensable method for live skeletal muscle characterization.</description><subject>Microscopy</subject><issn>2156-7085</issn><issn>2156-7085</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNpVUU1LxDAQDaKorHvzLL15sWvaJP24CLr4BQsLfpxDmk670SZZk1Tw35t1VXQuM2_m8WaGh9BxhmcZKej51fJ6ls8wjqDYQYd5xoq0xBXb_VMfoKn3LzgGpSUm1T46iDNWZ7Q6RPpei16ZPvGvMEAQQ6JHLwdIRv_VBWlNm6yE09YomfRgwImgrElE7Eu7AgcmRBBU-hjsK_jkQWhhEi9FCOA2IlpJZ720648jtNeJwcP0O0_Q88310_wuXSxv7-eXi1SSioS0xS2QOusoEUy0hBCgXV1KyvKa0a7KK9JiVnZtkeWCFi1taJNjWnaYlB3UDSMTdLHVXY-NhlbGE50Y-NopLdwHt0Lx_xOjVry375zgqmQ1iQKn3wLOvo3gA9fKSxgGYcCOnldFkdOa0iwyz7bMzY_eQfe7JcN84xGPHvGcbz2K9JO_l_2Sfxwhn-OXjw4</recordid><startdate>20110501</startdate><enddate>20110501</enddate><creator>Pfeffer, Christian P</creator><creator>Olsen, Bjorn R</creator><creator>Ganikhanov, Feruz</creator><creator>Légaré, François</creator><general>Optical Society of America</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20110501</creationdate><title>Imaging skeletal muscle using second harmonic generation and coherent anti-Stokes Raman scattering microscopy</title><author>Pfeffer, Christian P ; Olsen, Bjorn R ; Ganikhanov, Feruz ; Légaré, François</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-d0de391f43a5ad333e4f97c452954f8283d057fd612a46d4b4b2047f037fe9b53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Microscopy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pfeffer, Christian P</creatorcontrib><creatorcontrib>Olsen, Bjorn R</creatorcontrib><creatorcontrib>Ganikhanov, Feruz</creatorcontrib><creatorcontrib>Légaré, François</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biomedical optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pfeffer, Christian P</au><au>Olsen, Bjorn R</au><au>Ganikhanov, Feruz</au><au>Légaré, François</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Imaging skeletal muscle using second harmonic generation and coherent anti-Stokes Raman scattering microscopy</atitle><jtitle>Biomedical optics express</jtitle><addtitle>Biomed Opt Express</addtitle><date>2011-05-01</date><risdate>2011</risdate><volume>2</volume><issue>5</issue><spage>1366</spage><epage>1376</epage><pages>1366-1376</pages><issn>2156-7085</issn><eissn>2156-7085</eissn><abstract>We describe experimental results on label free imaging of striated skeletal muscle using second harmonic generation (SHG) and coherent anti-Stokes Raman scattering (CARS) microscopy. The complementarity of the SHG and CARS data makes it possible to clearly identify the main sarcomere sub-structures such as actin, myosin, acto-myosin, and the intact T-tubular system as it emanates from the sarcolemma. Owing to sub-micron spatial resolution and the high sensitivity of the CARS microscopy technique we were able to resolve individual myofibrils. In addition, key organelles such as mitochondria, cell nuclei and their structural constituents were observed revealing the entire structure of the muscle functional units. There is a noticeable difference in the CARS response of the muscle structure within actin, myosin and t-tubule areas with respect to laser polarization. We attribute this to a preferential alignment of the probed molecular bonds along certain directions. The combined CARS and SHG microscopy approach yields more extensive and complementary information and has a potential to become an indispensable method for live skeletal muscle characterization.</abstract><cop>United States</cop><pub>Optical Society of America</pub><pmid>21559148</pmid><doi>10.1364/BOE.2.001366</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2156-7085
ispartof Biomedical optics express, 2011-05, Vol.2 (5), p.1366-1376
issn 2156-7085
2156-7085
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3087593
source PubMed Central; EZB Electronic Journals Library
subjects Microscopy
title Imaging skeletal muscle using second harmonic generation and coherent anti-Stokes Raman scattering microscopy
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T12%3A58%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Imaging%20skeletal%20muscle%20using%20second%20harmonic%20generation%20and%20coherent%20anti-Stokes%20Raman%20scattering%20microscopy&rft.jtitle=Biomedical%20optics%20express&rft.au=Pfeffer,%20Christian%20P&rft.date=2011-05-01&rft.volume=2&rft.issue=5&rft.spage=1366&rft.epage=1376&rft.pages=1366-1376&rft.issn=2156-7085&rft.eissn=2156-7085&rft_id=info:doi/10.1364/BOE.2.001366&rft_dat=%3Cproquest_pubme%3E866249441%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c383t-d0de391f43a5ad333e4f97c452954f8283d057fd612a46d4b4b2047f037fe9b53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=866249441&rft_id=info:pmid/21559148&rfr_iscdi=true